Unigreen Minibar, Ventagli, Super Spalliera, RV-GDC manual Blower Group, Multiplier FAN Unit, Clutch

Page 17

5BLOWER GROUP

All the mistblowers have a high speed fan rotor. You must take great care and beware of the effects that this can provoke: such as the aspiration and projection of foreign bodies which, although of a small size, can be very dangerous especially for the eyes and face.

5.1MULTIPLIER - FAN UNIT

The Airdrop range is fitted with two versions of a Ø500 centrifugal fan: STD (max absorption 30 HP) and XP (max 50 HP).

The transmission of the drive from the pump to the fan is done through a multiplier with one or two gears, plus neutral.

Normally the rotation speed of the fan is 3240 RPM in first gear and 3620 RPM in second in the 2-speed multiplier (multiplied ratios 1:6 - 1:6.7) with the power takeoff running at 540 RPM.

You can change from one gear to the next with the lever on the multiplier, made accessible through the opening on the side in the rear left part of the machine or at a distance on the right side. The lever has 2 or 3 positions depending on the number of gears and the central position is neutral (to use only the pump without the fan).

WARNING: the gear change lever must only be used with the power-takeoff disengaged and the fan stopped. If it is difficult to engage, turn the cardan shaft slightly by hand to find the right position of the lever (make sure the tractor is turned off).

Ø500 fan with multiplier, 2-speed plus neutral.

For the maintenance of the multiplier (see point "Multiplier Lubrication"

5.5CLUTCH

Fans have a centrifugal type clutch that makes it possible to engage the fan rotor gradually.

This prevents jerky starts, due to the inertia of the fan rotor, which can have a negative effect on the transmission.

For the centrifugal clutch to work properly the speed of the power-takeoff mustn’t be less than 450 rpm, especially if you are using the first gear of the multiplier.

Generally clutches with shoes/plates made of sintered material with a high coefficient of friction are fitted, on some low power models rubber clutches may be fitted.

WARNING! As there is a high multiplication ratio, the fan must be started gradually. Suddenly engaging the power-takeoff clutch (at high speed) can damage the gears.

WORK TEMPERATURE

Heat is generated by the friction between the various moving components and on the basis of the power transmitted. The temperature

of the multiplier or disengaging box depends on the capacity to dissipate heat to the surrounding environment and therefore the surfaces involved in the heat exchange and the environmental conditions.

The specifications refer to environmental conditions with a temperature between -10° +50°C (14°C -122°F).

The working temperature limit of the box is 90°C (200°F) established to prevent the ageing of the seals and guarantee a sufficient viscosity of the oil. The heat makes the air in the box expand and therefore increases the pressure inside. The correct use of the oil seals is guaranteed up to an internal pressure of 0.5 bar. Boxes designed to be used for particularly heavy duty work are equipped with a breather cap that can be fitted

on any cast iron box on request.

Ø500 Nylon impeller with sinterized expansion clutch.

unigreen 17

Image 17
Contents 09/2006 USE and Maintenance ManualSummary Hand Lances Maintenance Guarantee Using and Keeping the USE and Maintenance ManualComposition of the Manual Product Responsibility Unigreen spa is not responsible ifKey to the symbols Intended USE Using Chemical ProductsProhibited USE Regulations for the USE of Chemical ProductsWeather Conditions Characteristics and SpecificationsDriving on the Road Tables of Fittings AllowedStandards of Reference Noise Level of the MachineInstructions Description of the MachineTowed Atomisers Parking Preliminary ChecksTransporting and Moving the Machine THREE-POINT Coupling Tractor CouplingFor verification use the formula shown here Hydraulic Connection to the DistributorsSuction Filter Cardan ShaftPump Components of the Pressure Regulator Pressure RegulatorControl box for GCP Elettrico electrical regulators General InstructionsTank rinsing Ejector Agitator Delivery Filters only Equipped ModelsAuxiliaries Taps Block Filling the Tank Test with Clean WaterManual Premixing Mixing12.2PREMIXER on Cover Optional 12.4COVER Washer for Chemical Containers13.1CIRCUIT Washer and Tank Washer Washing the AtomiserClutch Blower GroupMultiplier FAN Unit Super Spalliera for Espalier Ventagli Fans CANOPY, and Espalier DistributorsMinibar for Espalier Hydraulics RV Boom for GDCOIL Feed from Tractor for hydraulic systems RV per GDCNON-DRIP Valve Spraying Description of the DiffusersDescription of the MFC Nozzles Mistblower CalibrationCalibrated Plates CP Batching Taps see PictureProgrammed Maintenance MaintenanceRoutine Maintenance Cleaning the NozzlesPutting Back Into Service After Winter Layup Extraordinary MaintenanceMultiplier Lubrication RepairsElectrical and Electronic Apparatus Waste Eeaw Demolition and DisposalMaterials for Demolition Tables for Calibrating Airdrop 2 Ventagli Fans Airdrop Calibrating TablesTables for Calibrating Airdrop 2 Ventagli + TOP Diffusors OptionalTables for Calibrating Airdrop Minibar Piastrina CalibrataTables for Calibrating Airdrop RV-GDC Tables for Calibrating Airdrop Super SpallieraTables of Delivery of Nozzles for Hand Lances 50 h 300 h Table of Programmed Maintenance OperationTAB a TAB.18A Allowed FittingsMember of the group