Unigreen Ventagli Spraying Description of the Diffusers, NON-DRIP Valve, Mistblower Calibration

Page 20

R

V

FIG. 18

 

FIG. 19

20unigreen

6SPRAYING

WARNING: the indications to follow when using chemical products are indicated in paragraph 2.2.1.

6.1DESCRIPTION OF THE DIFFUSERS

The distributor accessories of the AIRDROP range are equipped with variable diffusers (FIG. 18) that let you direct the airflow (and as a consequence the treatment) on the vegetation to treat, adapting to your various needs.

According to the configuration of the accessory the diffusers have outlet mouths with different shapes and sections, furthermore they are equipped with a tap for turning the liquid on/off (R) so you can independently close one or more diffusers in the case of scarce vegetation.

In the VENTAGLI version the diffuser is the fan itself.

6.1.1 NON-DRIP VALVE

There is a non-drip valve (V) on the distributors (FIG. 18) that limits and/stops the mix dripping when the supply tap is closed. In any case we recommend closing the delivery of the mix a few seconds before disconnecting the power takeoff.

In versions with fans the valve is mounted immediately upstream of the dosing taps (see paragraph 6.4.1)

6.2DESCRIPTION OF THE MFC® NOZZLES

The Unigreen low-volume pneumatic atomization system uses MFC® nozzles (FIG. 19) consisting of a steel wire supported by Nylon deflector vanes that also act as collectors for the liquid. The high-speed action of the air atomises the film of liquid on the wire; in this there is a high air/water surface area in contact and not just a single atomisation point, which means a big advantage in terms of uniformity and homogeneity of the jet.

6.3MIXTURE CONCENTRATION

As you may know, the pneumatic equipment are used for more or less concentrated treatments. To prepare the mixture, it is necessary to follow the instructions on the chemical product label. As a general rule, the product quantity to be sprayed on the hectare is the same as normal-volume treatments (a 20%-reduction is also possible); the water volume is reduced a lot even up to 9 times = 10 concentrations.

We will try to clear this concept as regards concentration with an example for the correct use both of equipment and products.

Imagine that in order to protect a normal-volume culture hectare you use 15 ml. of mixture. If the product dose recommended by the expert amounts to 100 g/hl. (normal-volume dose indicated on the label which is always to be followed), for 15 hl. You will use 1,5 kg. of prod- ucts. If you decide to reduce the water quantity per hectare at 500-300-150 litres (that is to say concentrating 3-5-10 times), in these new water

volumes we must always use 1,5 kg. of product and 1,2 kg. if necessary (for reductions up to 20%). As a consequence, the mixture concentration can vary according to the water quantity that you wish to use.

From this example, you can notice a reduction of 4 fillings and 12 ml. of water.

5MISTBLOWER CALIBRATION

The tables on pages 25 to 28 make it possible to determine the delivery in litres/hectares of the various equipment having the following initial data:

-position of the batching tap levers (Ventagli - Fans)

-calibrated plate CP (all others diffusors)

-used pressure;

-working speed (in km/h);

-working length (in meters).

Image 20
Contents USE and Maintenance Manual 09/2006Summary Hand Lances Maintenance Using and Keeping the USE and Maintenance Manual GuaranteeComposition of the Manual Product Responsibility Unigreen spa is not responsible ifKey to the symbols Using Chemical Products Intended USEProhibited USE Regulations for the USE of Chemical ProductsCharacteristics and Specifications Weather ConditionsDriving on the Road Tables of Fittings AllowedNoise Level of the Machine Standards of ReferenceInstructions Description of the MachineTowed Atomisers Parking Preliminary ChecksTransporting and Moving the Machine Tractor Coupling THREE-POINT CouplingFor verification use the formula shown here Hydraulic Connection to the DistributorsSuction Filter Cardan ShaftPump Pressure Regulator Components of the Pressure RegulatorControl box for GCP Elettrico electrical regulators General InstructionsTank rinsing Ejector Agitator Delivery Filters only Equipped ModelsAuxiliaries Taps Block Test with Clean Water Filling the TankMixing Manual Premixing12.2PREMIXER on Cover Optional 12.4COVER Washer for Chemical ContainersWashing the Atomiser 13.1CIRCUIT Washer and Tank WasherClutch Blower GroupMultiplier FAN Unit Super Spalliera for Espalier Ventagli Fans CANOPY, and Espalier DistributorsMinibar for Espalier RV Boom for GDC HydraulicsOIL Feed from Tractor for hydraulic systems RV per GDCSpraying Description of the Diffusers NON-DRIP ValveDescription of the MFC Nozzles Mistblower CalibrationBatching Taps see Picture Calibrated Plates CPMaintenance Programmed MaintenanceRoutine Maintenance Cleaning the NozzlesExtraordinary Maintenance Putting Back Into Service After Winter LayupMultiplier Lubrication RepairsElectrical and Electronic Apparatus Waste Eeaw Demolition and DisposalMaterials for Demolition Airdrop Calibrating Tables Tables for Calibrating Airdrop 2 Ventagli FansOptional Tables for Calibrating Airdrop 2 Ventagli + TOP DiffusorsPiastrina Calibrata Tables for Calibrating Airdrop MinibarTables for Calibrating Airdrop Super Spalliera Tables for Calibrating Airdrop RV-GDCTables of Delivery of Nozzles for Hand Lances Table of Programmed Maintenance Operation 50 h 300 hTAB.18A Allowed Fittings TAB aMember of the group