IN & OUT SETTINGS (FM VERSION) | ENG | |
|
|
|
12.6ADDITIONAL DATA AND SETTINGS
12.6.1 SERIAL PORT SETUP
Serial Port Setup displays the serial port 1 and Port 2 status and allows to enable/disable them.
-Serial Port 1 This selection allows you to enable / disable the port
-Serial Port 2 This selection allows you to enable / disable the port
12.6.2 SYSTEM INFO
The System Info page provides useful data concerning Falcon 15 operation:
-Temperature it shows the internal temperature of the processor during operation. The current temperature is updated each time this option is accessed.
For proper operation, the temperature should never exceed 50 °C. If this threshold is exceeded, you must leave a ventilation space equivalent to at least 1 rack unit both above and below the processor.
-Ext Inputs It displays the current state of the three Digital Data inputs (see par. 11.10). IN=1 means active input, IN=0 means input disabled
-FW Version It shows the current Falcon 15 firmware version. Firmware may be upgraded to later versions (ref to Chapter 20.1)
-FW Code It shows firmware serial code. The user might be requested to communicate it to the manufacturer in some cases
Page 34