ACCESSING THE TARGET FROM THE PC | ENG | |
|
|
|
17.1THE SETUP PANEL
17.1.1 SELECTING THE PC SERIAL PORT
First of all, it is necessary to indicate which computer serial port is dedicated to the communication with the processor (COM 1, 2, 3, 4 to 8). Once a port is assigned, click ‘Connect’ buton to attempt the connection to the processor.
-If the serial port selected is physically present on the computer but is not connected to the processor, the control program will display ‘Remote Data not Available’. This means that the program is unable to connect to the processor.
-If the serial port is NOT physically present on the computer, the message ‘Selected Serial port not available’ will appear just below the display screen.
NOTE: the program tests the connection mode each time you access the Setup screen. However, the ‘Connect’ button allows You to try to connect the target at any time.
If link fails, some Setup or connection element may be wrong. A troubleshooting guide is provided
POSSIBLE CAUSE | SOLUTION |
|
|
The selected COM PORT is not available | Change Yr Pc Port selection or free the selected one. |
|
|
Addressed Target firmware version does not match the |
|
current version on the Pc (f.i.: Your Falcon 15 features | Update the processor |
rel 1.1 firmware and the Pc control software is updated |
|
to rel 1.2). |
|
Serial cable is not ok
Check the serial cable (type and electrical integrity)
Page 55