FM VERSION DESCRIPTION | ENG | |
|
|
|
11.8DIGITAL AUDIO INPUT
Transformer balanced
To avoid malfunctions, only one digital connector may be connected at a time. Please keep the
The digital input accepts any sampling rate between 32 and 96 kHz. No user adjustment is necessary since a sample rate converter is built into the unit. Furthermore, digital input automatically recognizes the digital format (AES, EBU, SPDIF, etc.) and the type of connection (optic or coaxial).
Even though both analog and digital input audio cables can be connected, only one input can be set active (analog/digital input selection is done through the software parameter setting - par. 12.1). Input gain and level setting for digital input is fixed.
XLR pinout: | Pin 1 | Gnd |
| Pin 2 | Signal |
| Pin 3 | Return |
In case of unbalanced connections (as required by S/PDIF format), shortcut pin 3 and 1 or connect the unbalanced signal to XLR Pin 2 (hot) and Pin 3 (Gnd).
11.9SERIAL PORTS
Falcon 15 features two optoinsulated RS232 serial ports which allow the remote control and RDS programming via a connected PC (ref to Chapter 16).
Connect a standard serial cable (not crossed) between the
The ports can be separately enabled / disabled via the menu (see par. 12.6.1).
The two serial ports support Tx and Rx signals only. One serial cable comes with the unit.
Page 21