Snapper G1000 Troubleshooting, Problem, Cause, Correction, No AC output is available, but

Page 15
TROUBLESHOOTING

Snapper G1000 Generator

TROUBLESHOOTING

Problem

Cause

Correction

 

 

 

 

 

 

1.

One of the circuit breakers is

1.

Reset circuit breaker.

 

 

open.

 

 

No AC output is available, but

2.

Fault in generator.

2.

Contact Authorized service facility.

3.

Poor connection or defective cord

3.

Check and repair.

generator is running.

 

set.

 

 

 

 

 

 

 

4.

Connected device is bad.

4.

Connect another device that is in

 

 

 

 

good condition.

 

 

 

 

 

Generator runs good at no-load

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

 

 

 

 

but "bogs" down" when loads are

2.

Generator is overloaded.

2.

See "Don't Overload Generator".

connected.

3.

Shorted generator circuit.

3.

Contact Authorized service facility.

 

 

 

 

Generator will not start; or starts

Low oil level.

Fill crankcase to proper level or place

and runs rough.

 

 

generator on level surface.

 

 

 

 

 

Generator shuts down during

1.

Out of gasoline.

1.

Fill fuel tank.

2.

Low oil level.

2.

Fill crankcase to proper level or

operation.

 

 

 

place generator on level surface.

 

 

 

 

 

 

 

Generator lacks power.

Load is too high.

See "Don't Overload Generator".

 

 

 

 

 

15

Image 15
Contents Questions? Help is just a moment away BRIGGS & STRATTON POWER PRODUCTS GROUP, LLCJEFFERSON, WISCONSIN, U.S.A G1000EQUIPMENT DESCRIPTION TABLE OF CONTENTSSAFETY RULES Hazard Symbols and MeaningsBreathing carbon monoxide will cause nausea, fainting or death Generator produces powerful voltageBattery electrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burnsUnintentional sparking can result in fire or electric shock Broken bones, fractures, bruises or sprains could resultSevere burns can occur on contact Combustible debris, such as leaves, grass, brush, etc. can catch fireKNOW YOUR GENERATOR Engine ON/OFF Switch - Used to stop a running engineRemove Generator From Carton ASSEMBLYCarton Contents BEFORE STARTING ENGINEGenerator Location USING THE GENERATORConnecting to a Building’s Electrical System System GroundCombustible debris, such as leaves, grass, brush, ect. can catch fire Connecting Electrical LoadsOPERATING THE GENERATOR Starting the EngineCharging a Battery Stopping the EngineTo recharge 12 Volt batteries, proceed as follows COLD WEATHER OPERATION CONNECTOR PLUGS12 Volt DC Accessory Jack EXTENSION CORDS7. Cut off all carton flaps Example Power ManagementDONT OVERLOAD GENERATOR CapacityGenerator Maintenance SPECIFICATIONSGENERAL MAINTENANCE RECOMMENDATIONS Engine MaintenanceOther Storage Tips STORAGEGenerator Storage Engine StorageGenerator lacks power TROUBLESHOOTINGProblem but bogs down when loads areSnapper G1000 Generator BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC SNAPPER OWNER WARRANTY POLICY Effective August 1 LIMITED WARRANTYWARRANTY PERIOD About your equipment warrantyADVERTENCIA TABLA DE CONTENIDOSDESCRIPCIÓN DEL EQUIPO INSTRUCCIONES DE SEGURIDADCUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO Los generadores producen un voltaje muy poderosoUna pequeña chispa puede encender el hidrógeno y causar una explosión CUANDO AÑADA COMBUSTIBLE O VACÍE EL DEPÓSITOLos residuos como hojas, hierba, maleza, etc. se pueden inflamar PRECAUCIÓNComo resultado, podrían producirse fracturas, contusiones o esguinces Quemaduras severas pueden ocurrir al hacer contactoBujía cubierta del interior CONOZCA SU GENERADORContenido de la Caja MONTAJEANTES DE DARLE ARRANQUE AL MOTOR Para Retirar El Generador De La CajaUbicación del Generador USO DEL GENERADORTierra del Sistema Conexión al Sistema Eléctrico de un EdificioFigura 9 - Válvula del Combustible en la Posición Abierta OPERANDO EL GENERADOR PRECAUCIÓNEncienda el Motor Conexion De Cargas ElectricasParado Del Motor Procedimiento de Carga de la BateriaFigura 10 - Conexiones De la Batería Receptáculo de 120 Voltios AC ENCHUFES DE CONEXIÓN PRECAUCIÓNCABLES DE EXTENSIÓN OPERACIÓN DURANTE UN CLIMA FRÍOFigura 13 - Refugio Frío Permanente del Tiempo Ejemplo NO SOBRECARGUE EL GENERADORCapacidad Control de la EnergíaPara Limpiar el Generador ESPECIFICACIONESRECOMENDACIONES GENERALES DE MANTENIMIENTO Mantenimiento del MotorOtras Sugerencias Para el Almacenando ALMACENAMIENTOAlmacenando el Generador Almacenando el MotorCausa ProblemoDIAGNÓSTICO Y REPARACIÓN DE AVERÍAS AccionEquipo POLÍTICA PARA EL PROPIETARIO DE EQUIPOS SNAPPEREfectiva desde el 1 ro de Agosto PERIODO DE GARANTÍA