Husky 1800 Series, 70 Series manual Direct Mount on Underground Tanks

Page 11

Installation

Direct Mount on Underground Tanks

1.Screw 2" coupling onto 2" standard pipe.

2.Screw 2" standard pipe into 2" tank flange. Apply compound to threads at bottom of base to prevent surface water from entering the tank.

3.Screw 1" suction pipe into install-a-socket. Suction pipe should be long enough to allow 3" clearance from bottom of tank. Apply gasoline-resistant pipe compound to male threads.

4.Lower 1" suction pipe through 2" standard pipe into tank. Tighten install-a-socket into coupling at top of standard pipe.

5.Screw pump (2" threaded base) into install-a-socket. This is a suction line connection and must be tight. Apply gasoline-resistant pipe compound to male threads.

See the Conduit section for correct installation of electrical conduit.

9312

2-5

Image 11
Contents Gasboy INTERNATIONAL, INC. a Tokheim Subsidiary LANSDALE, PA Installers ImportantGasboy INTERNATIONAL, INC Important Warnings and SafeguardsContents Gasboy Series 70 WarrantyPurpose SpecificationsIntroduction Series 70 and 1820 Features Installation Precautions InstallationSupply Line Underground Tanks Pump Dimensions Model 1820R Pump Dimensions Series 70, ModelInstalling Hose and Nozzle Installation InstructionsDirect Mount on Underground Tanks Direct Mount on Aboveground Tank Pedestal Mount Pump Wall Mount As required Vacuum BreakerTesting the Vacuum Breaker Circuit Breakers WiringWiring Precautions Pump Motor Wire SizeWire Size GroundingConduit Pulser WiringPump Wiring Diagrams Startup PRE-STARTUP ChecklistStartup and Operation Tightness Strainer CleaningPOST-STARTUP Tests VoltageStart-Up and Operation Daily OperationPage Maintaining TROUBLE-FREE Operation Maintenance and TroubleshootingWhen Your Pump Needs Service Pump runs but wont prime or deliver product TroubleshootingPump Wont Start Pump hums but wont startPump loses prime Pump delivers product when not turned onPump delivers product but wont register Pump delivery is slowMETER-REGISTER Disassembly Disassembly of PumpReplacing Bearing and Seal Assembly Item 36, New Style 1860 3-WHEEL Register Service and MaintenanceReplacing Bearing and Seal Assembly Item 36, Old Style Replacing Bearing and Seal Assembly Item 16, Old Style 4860 4-WHEEL Register ServiceReplacing Bearing and Seal Assembly Item 26, New Style Parts Series 70 Assembly Optional Accessories Series 1820 Assembly See Direct Drive Motor parts breakdown Direct Drive MOTOR-PUMP Assembly Description Installation Parts Register Assemblies 4860 METER-REGISTER1860 3-WHEEL Meter Register for Model Change GEARS-IMPERIAL Gallons 4860 4-WHEEL Register for Model 72S and Series 1820R Change GEARS-US Gallons New Style Gasoline or Diesel Gasboy Series 70 Optional Kits for Series 70 and 1800 Pumps Gasboy Series 70 Model 1820R Parts List 1820R Pulser and Junction BOX Assemblies Warranty