Section 1
INTRODUCTION
PURPOSE
The GASBOY Series 70 and 1820 Consumer Electric Pumps Installation/Operation Manual is provided to assist the installer in installing and operating the unit. Faulty installations are the major cause of unit malfunctions. This manual should be supplied to the electrician prior to the installation of conduit and wiring. The Series 70 or 1820 pumps must be installed and operated as described in this manual. This manual also contains warnings, safeguards and procedures on the use and care of the pump. Be sure to leave this manual with the pump owner after the installation is complete.
☎Customers and installers having any questions pertaining to the installation should contact their GASBOY distributor.
SPECIFICATIONS
Series 70 and Series 1820 pumps are made specifically for private use on vented tanks. While their outward appearance differs, they basically offer the same features. These pumps can be mounted on aboveground skid tanks, directly mounted above underground tanks, or mounted on pedestals for remote underground installations. Table
Pumping Unit: | ||
| valve with pressure relief valve. | |
Motor: | 1/3 HP, 1725 RPM motor with thermal overload protection and auxiliary AC line. | |
| Standard 115 VAC, 60 Hz; optional 230 VAC, 50 Hz. AC junction box included. | |
Register: | 70: | |
| 1820: | |
|
| (Optional, except for 1820R: |
| Registers show delivery in US gallons, Imperial gallons, or liters and change gears are | |
| available to convert registers for unit of measure. | |
Meter: | Nutating disk phenolic measuring chamber in aluminum | |
| calibration +.5% at full flow | |
Hose & Nozzle: | 12' (3.66 m) | |
| closing nozzle. | |
Connections: | 2" (5.08 cm) NPT for tank opening; 1" (2.54 cm) suction; 3/4" (1.91 cm) NPT discharge | |
Strainer: | ||
Delivery Rate: | 18 GPM, at 115V, 60 Hz.; 60 LPM at 60 Hz.; 68 LPM at 50 Hz. | |
Finish: | ||
Approvals: | UL, CSA |
|
Additional extra cost options include: vapor recovery, vacuum breaker return line, longer hoses, hose breakaways, automatic nozzles, external filters, wall mounting kits, and for Series 1820 only, 10:1 pulser or rear- or
9312 |