Husky 1800 Series, 70 Series manual Introduction, Purpose, Specifications

Page 5

Section 1

INTRODUCTION

PURPOSE

The GASBOY Series 70 and 1820 Consumer Electric Pumps Installation/Operation Manual is provided to assist the installer in installing and operating the unit. Faulty installations are the major cause of unit malfunctions. This manual should be supplied to the electrician prior to the installation of conduit and wiring. The Series 70 or 1820 pumps must be installed and operated as described in this manual. This manual also contains warnings, safeguards and procedures on the use and care of the pump. Be sure to leave this manual with the pump owner after the installation is complete.

Customers and installers having any questions pertaining to the installation should contact their GASBOY distributor.

SPECIFICATIONS

Series 70 and Series 1820 pumps are made specifically for private use on vented tanks. While their outward appearance differs, they basically offer the same features. These pumps can be mounted on aboveground skid tanks, directly mounted above underground tanks, or mounted on pedestals for remote underground installations. Table 1-1 summarizes the features for each model.

Pumping Unit:

Self-priming, direct-drive rotary vane; 23 PSI (1.6 bars) stainless steel bypass; check

 

valve with pressure relief valve.

Motor:

1/3 HP, 1725 RPM motor with thermal overload protection and auxiliary AC line.

 

Standard 115 VAC, 60 Hz; optional 230 VAC, 50 Hz. AC junction box included.

Register:

70:

4-wheel push-button reset, 7-digit master totalizer

 

1820: 3-wheel, volume only; lever-type reset with interlock; 6-digit master totalizer

 

 

(Optional, except for 1820R: 4-wheel push-button)

 

Registers show delivery in US gallons, Imperial gallons, or liters and change gears are

 

available to convert registers for unit of measure.

Meter:

Nutating disk phenolic measuring chamber in aluminum die-cast housing; adjustable

 

calibration +.5% at full flow

Hose & Nozzle:

12' (3.66 m) UL-Listed hose assembly with integral static discharge wire; manual self-

 

closing nozzle.

Connections:

2" (5.08 cm) NPT for tank opening; 1" (2.54 cm) suction; 3/4" (1.91 cm) NPT discharge

Strainer:

100-mesh nylon

Delivery Rate:

18 GPM, at 115V, 60 Hz.; 60 LPM at 60 Hz.; 68 LPM at 50 Hz.

Finish:

High-gloss red urethane or color of choice. 1820 only: Stainless steel extra cost option.

Approvals:

UL, CSA

 

Additional extra cost options include: vapor recovery, vacuum breaker return line, longer hoses, hose breakaways, automatic nozzles, external filters, wall mounting kits, and for Series 1820 only, 10:1 pulser or rear- or side-mount filter kits.

9312

1-1

Image 5
Contents Gasboy INTERNATIONAL, INC. a Tokheim Subsidiary LANSDALE, PA Installers ImportantGasboy INTERNATIONAL, INC Important Warnings and SafeguardsContents Gasboy Series 70 WarrantyPurpose SpecificationsIntroduction Series 70 and 1820 Features Installation Precautions InstallationSupply Line Underground Tanks Pump Dimensions Model 1820R Pump Dimensions Series 70, ModelInstalling Hose and Nozzle Installation InstructionsDirect Mount on Underground Tanks Direct Mount on Aboveground Tank Pedestal Mount Pump Wall Mount As required Vacuum BreakerTesting the Vacuum Breaker Circuit Breakers WiringWiring Precautions Wire Size Wire SizeGrounding Pump MotorConduit Pulser WiringPump Wiring Diagrams Startup PRE-STARTUP ChecklistStartup and Operation POST-STARTUP Tests Strainer CleaningVoltage TightnessStart-Up and Operation Daily OperationPage Maintaining TROUBLE-FREE Operation Maintenance and TroubleshootingWhen Your Pump Needs Service Pump Wont Start TroubleshootingPump hums but wont start Pump runs but wont prime or deliver productPump delivers product but wont register Pump delivers product when not turned onPump delivery is slow Pump loses primeMETER-REGISTER Disassembly Disassembly of PumpReplacing Bearing and Seal Assembly Item 36, New Style 1860 3-WHEEL Register Service and MaintenanceReplacing Bearing and Seal Assembly Item 36, Old Style Replacing Bearing and Seal Assembly Item 16, Old Style 4860 4-WHEEL Register ServiceReplacing Bearing and Seal Assembly Item 26, New Style Parts Series 70 Assembly Optional Accessories Series 1820 Assembly See Direct Drive Motor parts breakdown Direct Drive MOTOR-PUMP Assembly Description Installation Parts Register Assemblies 4860 METER-REGISTER1860 3-WHEEL Meter Register for Model Change GEARS-IMPERIAL Gallons 4860 4-WHEEL Register for Model 72S and Series 1820R Change GEARS-US Gallons New Style Gasoline or Diesel Gasboy Series 70 Optional Kits for Series 70 and 1800 Pumps Gasboy Series 70 Model 1820R Parts List 1820R Pulser and Junction BOX Assemblies Warranty