Husky 70 Series, 1800 Series manual Pump Wiring Diagrams

Page 20

GASBOY Series 70 & 1820

PUMP WIRING DIAGRAMS

115VAC Pumps Series 70 and 1820 (left) and Series 1820R (right)

230VAC Pumps Series 70 and 1820 (left) and Series 1820R (right)

NOTE FOR 230V MOTORS: Some motors may contain different wire colors than those shown. In this case, Hot is Black, Neutral is White and Aux AC Control is Brown.

1.All wiring and conduit runs must conform with all building/fire codes, all Federal, State, and Local codes, National Electrical Code, (NFPA 70), NFPA 30, Automotive and Marine Service Station Code (NFPA 30A), and NFPA 395 codes and regulations.

2.For the Series 70 and Series 1820 rounded cabinet models, make the field wire connections in the motor junction box. The 1820R models with the squared cabinet come with the wires already extended through the end of a factory-installed conduit. The 1820R models also come with a junction box which is to be mounted directly beneath the pump. The field wire connections for the 1820R models should be made in this junction box (not the pump motor junction box). Wire connections should be tightly spliced and secured with a wire nut. Close off the end of the wire nut with electrical tape.

3.The Aux AC Control Lead wire is shipped capped from the factory. When used, it connects to a solenoid valve or fuel management system. Do not connect this wire without first checking the ON voltage of this line to ascertain compatibility with the equipment being connected.

4.Pulser wiring must be 18AWG and installed in metal conduit separate from all AC wiring. It cannot share a common junction box, wiring trough or conduit with any AC wiring.

3-4

9312

Image 20
Contents Installers Important Gasboy INTERNATIONAL, INC. a Tokheim Subsidiary LANSDALE, PAImportant Warnings and Safeguards Gasboy INTERNATIONAL, INCContents Warranty Gasboy Series 70Purpose SpecificationsIntroduction Series 70 and 1820 Features Installation Installation PrecautionsSupply Line Underground Tanks Pump Dimensions Series 70, Model Pump Dimensions Model 1820RInstallation Instructions Installing Hose and NozzleDirect Mount on Underground Tanks Direct Mount on Aboveground Tank Pedestal Mount Pump Wall Mount Vacuum Breaker As requiredTesting the Vacuum Breaker Circuit Breakers WiringWiring Precautions Wire Size Wire SizeGrounding Pump MotorPulser Wiring ConduitPump Wiring Diagrams Startup PRE-STARTUP ChecklistStartup and Operation Strainer Cleaning POST-STARTUP TestsVoltage TightnessDaily Operation Start-Up and OperationPage Maintenance and Troubleshooting Maintaining TROUBLE-FREE OperationWhen Your Pump Needs Service Troubleshooting Pump Wont StartPump hums but wont start Pump runs but wont prime or deliver productPump delivers product when not turned on Pump delivers product but wont registerPump delivery is slow Pump loses primeDisassembly of Pump METER-REGISTER DisassemblyReplacing Bearing and Seal Assembly Item 36, New Style 1860 3-WHEEL Register Service and MaintenanceReplacing Bearing and Seal Assembly Item 36, Old Style 4860 4-WHEEL Register Service Replacing Bearing and Seal Assembly Item 16, Old StyleReplacing Bearing and Seal Assembly Item 26, New Style Parts Series 70 Assembly Optional Accessories Series 1820 Assembly See Direct Drive Motor parts breakdown Direct Drive MOTOR-PUMP Assembly Description Installation Parts 4860 METER-REGISTER Register Assemblies1860 3-WHEEL Meter Register for Model Change GEARS-IMPERIAL Gallons 4860 4-WHEEL Register for Model 72S and Series 1820R Change GEARS-US Gallons New Style Gasoline or Diesel Gasboy Series 70 Optional Kits for Series 70 and 1800 Pumps Gasboy Series 70 Model 1820R Parts List 1820R Pulser and Junction BOX Assemblies Warranty