REMOTE CONTROL WIRING

Important Installation Notes for Remote or External Wiring Configuration

Remote wiring must be run in separate conduit.

Remote wiring must not be run parallel to high voltage lines.

For runs of under 30 feet, remote wiring should have stranded conductors with a minimum of 22 AWG, 600V, cable twisting 1.5 to 2.5 and jacketed.

For runs over 30 feet, the conductors should be a minimum of 20 AWG, 600V, cable twisting 1.5 to 2.5 inch lay that is shielded and jacketed.

Maximum cable length is 200 feet.

For both two- and three- wire remote systems, the provided 7-pin wiring connector must be utilized. Please refer to the wiring instructions.

Note: The remote wires must be connected to the

7-pin connector before it is connected to the board.

2-Wire Remote Control (On-Off)

This application assumes that only one heating function is required.

1.Turn on power to the heater.

2.Push the mode button to the "POOL" or "SPA" mode and set the desired temperature for each. (eg. 102°F)

3.Turnthemodebuttonto"OFF"andremovepowerfromthe heater.

4.On the "Remote Interface Harness" connect the BLUE wire to one side of the "REMOTE" switch and connect the other side to either the ORANGE/BLACK wire for "SPA" operationortheBLACK/ORANGEwirefor"POOL"opera- tion.

5.Place wire nut on unused wire on the "Remote Interface Harness."

6.Install the "7-Pin Remote Interface Harness" to the P8 connector and turn on power to the heater.

Fig# 9492

See instructions on previous page to activate the remote control.

3-Wire Remote Control Using Three-Position Switch (Pool-Off-Spa, or Low-Off-High)

This application assumes that multiple heating functions are required.

Fig# 9493

1.Turn on power to the heater.

2.Push the mode button to the "POOL" or "SPA" modes and set the desired temperature for each.

(eg. 80° for Pool and 102°F for Spa)

3.Turnthemodebuttonto"OFF"andremovepowerfromthe heater.

4.On the "Remote Interface Harness" connect the BLUE wire to one side of the "REMOTE" switch and connect the ORANGE/BLACK wire for "SPA" operation and the BLACK/ORANGE wire for the "POOL" operation.

5.Install the "Remote Interface Harness" to the P8 connec- tor and turn power "ON" to the heater.

See instructions on previous page to activate the remote control.

33

Image 33
Contents What to do if YOU Smell GAS Installation and Operating InstructionsPage Contents START-UP Procedures For Your Safety Read Before OperatingBefore START-UP Burners Water Millivolt System Lighting InstructionsTo Turn OFF GAS to Appliance Electronic Ignitions Systems What to do if YOU Smell GASOperating Instructions Water Pressure Switch Maintenance and Care ProceduresAfter START-UP Visual InspectionPool & SPA Water Chemistry Automatic Chlorinators Chemical FeedersCold Weather Operation Winterizing the Pool & SPA Heater General Specifications Receiving EquipmentStandardunitpolymerheaders Asme Unit Cast Iron Headers Installation Instructions Installations only OutdoorheaterinstallationIndoor Heater Installation Outdoor KIT IncludesIndoor KIT Includes Installing the Clips Indoor & Outdoor Kits Securing the TOP Panel Cover Indoor KIT onlySecuring the TOP Panel Cover Outdoor KIT only Installing the TOP Cover Outdoor KIT only Combustion and Ventilation AIR Indoor Units Only Specifications and DimensionsGAS Supply Connections Vent PipingGAS Pressure Adjustment Locations GAS Pressure RegulatorPipe Sizing for GAS Connections Flow Rates Plumbing for Water ConnectionsUnitherm Governor Operation Cast Iron Headrers Asme ModelsAuxiliary Bypass Valve Adjustment External Auxiliary Bypass Valve Where RequiredHeat Exchanger Pressure Drop Tables For Asme Models call your factory representative Heat Exchanger Reversal Procedure Polymer Header ModelsElectrical Wiring Millivolt SystemElectronic Transformer Wiring 120V Wiring 240V WiringIndependently Wiring Diagram Millivolt Mechanical Thermostat Wiring Diagram IID Atmospheric Wiring Diagram IID Low NOx General Location of Controlscontrol Adjustments Control Panel RemovalMillivolt Controls Digital Thermostat Controls Thermostat Control Operation Fahrenheit vs Centigrade Diagnostics Reading a FaultDisplay Definition Remote Control Installation and Operation Remote OperationActivating the Remote Wire Remote Control On-Off Remote Control WiringFlame ROLL-OUT Safety Switch Pressure SwitchPilot SAFETY- Millivolt Pilot SAFETY- ElectronicBurner Drawer Removal Pilot Removal and CleaningGAS Valve Removal Main Burner and Orifice RemovalDesootingprocedure TubecleaningprocedureImmersion Well Replacement Unitherm Governor U.G. ReplacementBurneradjustment START-UP ProceduresBlower Adjustment Flame ROLL-OUT Safety SwitchCombustion FAN Removal Pilot RemovalMechanicalforqualifiedservicepersonnelonly Troubleshooting GuideRaypak Pool or SPA Heater Electrical Check with MV GAS Valve Electrical Standing Pilot MillivoltFor qualified technicians only Electrical Electronic Ignition IID TroubleshootingDigital Control Logic Flow Chart Replacement Parts RAYPAK, INCEastman Avenue Oxnard, CA For Canada Illustrated Parts List Pilot Assemblies Page Page Page Page Page