Raypak RP2100 Electronic Ignitions Systems, What to do if YOU Smell GAS, Operating Instructions

Page 6

CAUTION: Propane gas is heavier than air and will settle on the ground. Since propane can accumulate in confined areas, extra care should be exercised when lighting propane heaters.

OPERATING INSTRUCTIONS AND SHUT-OFF PROCEDURES

AUTOMATICALLY LIGHTED PILOTS

ELECTRONIC IGNITIONS SYSTEMS

A.

This appliance is equipped with an ignition

 

*If you cannot reach your gas supplier, call the fire

 

device which automatically lights the pilot. Do

 

department.

 

not try to light the pilot by hand.

 

 

 

 

B.

BEFORE OPERATING, smell all around the

 

C. Use only your hand to push in or turn the gas

 

 

control knob. Never use tools. If the knob will

 

appliance area for gas. Be sure to smell next

 

 

not push in or turn by hand, don't try to repair

 

to the floor because some gas is heavier than

 

 

it; call a qualified service technician. Force or

 

air and will settle on the floor.

 

 

attempted repair may result in fire or explo-

 

WHAT TO DO IF YOU SMELL GAS:

 

 

sion.

 

 

 

 

 

 

*Do not try to light any appliance.

 

D. Do not use this appliance if any part has been

 

*Do not touch any electric switch; do not use

 

 

underwater. Immediately call a qualified serv-

 

any phone in your building

 

 

ice technician to inspect the appliance and to

 

*Immediately call your gas supplier from a

 

 

replace any part of the control system and any

 

neighbor's phone. Follow the gas supplier's

 

 

gas control which has been underwater.

 

instructions.

 

 

 

 

 

 

OPERATING INSTRUCTIONS

 

 

 

 

 

1. STOP! Read the safety information above.

GAS CONTROL KNOB SHOWN IN "ON" POSITION

 

2. Set the thermostat to the lowest setting.

 

 

 

 

 

3. Turn off all electric power to the appliance.

 

 

 

HONEYWELL

 

4. This appliance is equipped with an ignition

GAS

 

 

 

device which automatically lights the pilot.

 

 

VR 8300 GAS

 

INLET

 

 

 

VALVE IID

 

Do not try to light the pilot by hand.

 

 

 

 

 

 

 

 

5.Remove heater door panel.

6.For Honeywell Valve: Turn gas control

knob clockwise to "Off".

For Robertshaw valve: Turn gas control

knob clockwise

 

 

to "Off".(Models

ROBERTSHAW 7000

265-405) Push i

n and

move gas control

GAS VALVE IID

lever counter-clockwise

 

to "Off"

MODEL 265-405

 

position. (Model 185)

 

 

 

 

 

 

7.Wait 5 minutes to clear out any gas. If you then smell gas STOP! Follow "B" in the safety information previously stated. If you

 

don't smell gas, go to the next step.

 

Fig. # 8080.0

 

 

 

8.

Turn gas control knob counter-clockwise

GAS CONTROL

 

 

 

to "On". (Honeywell VR 8300 and

LEVER SHOWN

 

 

 

 

 

 

 

IN "OFF"

 

 

Robertshaw 7000)

 

 

POSITION

ROBERTSHAW

9.

Replace heater door panel.

 

 

7200 GAS VALVE

10.

Turn on all electric power to the appliance.

 

 

IID MODEL 185

11.

Set thermostat to desired setting.

GAS

 

12.

If the appliance will not operate, follow the

 

INLET

 

 

instructions "To Turn Off Gas To Appliance"

 

 

 

 

and call your service technician or gas

Fig. # 8934.1

supplier.

 

 

TO TURN OFF GAS TO APPLIANCE

 

 

 

1.Set the thermostat at the lowest setting.

2.Turn off all the electric power to the appliance if service is to be performed.

3.Remove heater door panel.

4.For Honeywell VR 8300 and Robertshaw 7000 gas valve.

Turn gas control knob clockwise

to "Off". Make sure knob rest against stop.

For Robertshaw 7200 gas valve.

Push in and move gas control lever counter-

clockwise to "Off" position.

5. Replace heater door panel.

6

Image 6
Contents Installation and Operating Instructions What to do if YOU Smell GASPage Contents START-UP Procedures For Your Safety Read Before OperatingBefore START-UP Burners Water Millivolt System Lighting InstructionsTo Turn OFF GAS to Appliance Electronic Ignitions Systems What to do if YOU Smell GASOperating Instructions After START-UP Maintenance and Care ProceduresWater Pressure Switch Visual InspectionPool & SPA Water Chemistry Automatic Chlorinators Chemical FeedersCold Weather Operation Winterizing the Pool & SPA Heater General Specifications Receiving EquipmentStandardunitpolymerheaders Asme Unit Cast Iron Headers Installation Instructions Outdoorheaterinstallation Installations onlyIndoor Heater Installation Outdoor KIT IncludesIndoor KIT Includes Installing the Clips Indoor & Outdoor Kits Securing the TOP Panel Cover Indoor KIT onlySecuring the TOP Panel Cover Outdoor KIT only Installing the TOP Cover Outdoor KIT only Specifications and Dimensions Combustion and Ventilation AIR Indoor Units OnlyVent Piping GAS Supply ConnectionsGAS Pressure Adjustment Locations GAS Pressure RegulatorPipe Sizing for GAS Connections Plumbing for Water Connections Flow RatesCast Iron Headrers Asme Models Unitherm Governor OperationExternal Auxiliary Bypass Valve Where Required Auxiliary Bypass Valve AdjustmentHeat Exchanger Pressure Drop Tables Heat Exchanger Reversal Procedure Polymer Header Models For Asme Models call your factory representativeElectrical Wiring Millivolt SystemElectronic Transformer Wiring 120V Wiring 240V WiringIndependently Wiring Diagram Millivolt Mechanical Thermostat Wiring Diagram IID Atmospheric Wiring Diagram IID Low NOx General Location of Controlscontrol Adjustments Control Panel RemovalMillivolt Controls Digital Thermostat Controls Thermostat Control OperationFahrenheit vs Centigrade Diagnostics Reading a FaultDisplay Definition Remote Control Installation and Operation Remote OperationActivating the Remote Remote Control Wiring Wire Remote Control On-OffPilot SAFETY- Millivolt Pressure SwitchFlame ROLL-OUT Safety Switch Pilot SAFETY- ElectronicGAS Valve Removal Pilot Removal and CleaningBurner Drawer Removal Main Burner and Orifice RemovalImmersion Well Replacement TubecleaningprocedureDesootingprocedure Unitherm Governor U.G. ReplacementBlower Adjustment START-UP ProceduresBurneradjustment Flame ROLL-OUT Safety SwitchPilot Removal Combustion FAN RemovalTroubleshooting Guide MechanicalforqualifiedservicepersonnelonlyElectrical Standing Pilot Millivolt Raypak Pool or SPA Heater Electrical Check with MV GAS ValveElectrical Electronic Ignition IID Troubleshooting For qualified technicians onlyDigital Control Logic Flow Chart Replacement Parts RAYPAK, INCEastman Avenue Oxnard, CA For Canada Illustrated Parts List Pilot Assemblies Page Page Page Page Page
Related manuals
Manual 46 pages 34.19 Kb

P-R185B to R-P405B, C-R185B to C-R405B, P-R185BL to P-R405BL, C-R185BL to C-R405BL, RP2100 specifications

Raypak is a leading manufacturer in the heating and cooling industry, renowned for its innovative products that cater to both residential and commercial sectors. One of its product lines, the RP2100 series, exemplifies cutting-edge technology and features designed to enhance efficiency and performance in pool heating systems.

The RP2100 models, particularly the P-R185B through R-P405B series, incorporate advanced heat exchanger technology, enabling them to offer exceptional heat transfer efficiency. The titanium heat exchangers are designed for durability and resistance against corrosion, particularly in saltwater environments, ensuring the longevity of the system. These units are engineered for both outdoor and indoor applications, with the versatility to adapt to various heating requirements.

In terms of energy efficiency, the RP2100 series boasts a high coefficient of performance (COP), making them cost-effective solutions for pool heating. They are equipped with digital thermostats that provide accurate temperature control, ensuring consistent heating capabilities while minimizing energy consumption. The inclusion of intelligent controls allows for seamless integration with existing systems and provides users with the ability to schedule heating cycles, further enhancing energy savings.

Moving beyond the RP2100 series, the C-R185B to C-R405B models are specifically tailored for commercial applications, combining robust performance with user-friendly features. These commercial heaters are designed to handle larger volumes of water and are built to withstand the rigors of high-traffic environments, such as resorts and sports complexes. Their vertical design optimizes space and promotes better airflow, which is crucial in high-demand scenarios.

The P-R185BL to P-R405BL and C-R185BL to C-R405BL models feature noise-reducing technology, making them suitable for residential settings where peace and quiet are paramount. They utilize advanced acoustic insulation materials that minimize operational noise without sacrificing performance.

In summary, the Raypak RP2100, P-R185B to R-P405B, C-R185B to C-R405B, P-R185BL to P-R405BL, and C-R185BL to C-R405BL series represent the pinnacle of innovation in pool heating solutions. With their durable construction, energy-efficient designs, and advanced technologies, these models are ideal for users seeking reliability, efficiency, and quiet operation in both residential and commercial environments. Investing in Raypak products ensures superior heating performance, longevity, and overall satisfaction.