Raypak RP2100 Specifications and Dimensions, Combustion and Ventilation AIR Indoor Units Only

Page 16

SPECIFICATIONS AND DIMENSIONS

 

 

 

 

 

 

 

 

Shipping Weights (lbs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTUH

(A)

(B)

(C)

(J)

 

 

Cast Iron

Capron

 

 

 

 

 

Heater

Heater

 

Indoor

Heater

Input

Cabinet

Flue

Indoor

 

Gas

Water

 

 

w/Stackless

w/Stackless

 

Draft-

Model

(000)

Width

Dia.

Drafthood

 

Conn.

Conn.

Top

Top

 

hood

R185B

181

18-1/4"

6"

62-5/8"

12-1/16"

3/4"

2"

191

172

 

12

R265B

264

22-3/8"

7"

62-7/8"

11-1/8"

3/4"

2"

214

195

 

15

R335B

334

25-3/4"

8"

63-3/4"

10-3/4"

3/4"

2"

234

215

 

17

R405B

399

29-1/4"

9"

65-3/8"

12-1/2"

3/4"

2"

253

234

 

20

*Designation for Propane is "EP", Natural gas is "EN". Prefix "C" is for Cast Iron (ASME) Headers; "P" is for Plastic (Polymer) Headers. Atmospheric heaters: reduce input 4% for each 1000 ft. above sea level when installed above 2000 ft. elevation. Low NOx heaters: for elevations above 5,000 feet consult factory. For Canada, no de-rating is required for elevations up to 4500 feet. Manufactured under Patent No. 3,623,458. Note: Plastic (Polymer) headers cannot be used for ASME installations.

Fig # 9037.2

*Electrical Connection On Left Side is 19-1/8".

COMBUSTION AND VENTILATION AIR (Indoor Units Only)

Theheatermusthavebothcombustionandventilationair. Minimum requirements for net free air supply openings, one opening that is 12 inches from the ceiling for ventilation and one opening that is 12 inches from the floor for combustion air as outlined in the latest edition of the National Fuel Gas Code, ANSI Z2231(Canada-CAN/ CGA-B149.1 and B149.2) and any local codes that may have jurisdiction.

CAUTION: Combustion air must not be contaminated by corrosive chemical fumes which can damage the heater and void the warranty.

a. All Air From Inside The Building:

Each opening shall have a minimum net free square

inches as noted:

 

 

Model Square Inches Model Square Inches

185

181

335

333

265

264

405

399

b. All Air From Outdoors:

When air is supplied directly from outside of building, each opening shall have a minimum net free square

inches as noted:

 

 

 

 

Model

 

Square Inches

 

185

 

46

 

265

 

66

 

335

 

84

 

405

 

100

 

 

16

Image 16
Contents Installation and Operating Instructions What to do if YOU Smell GASPage Contents For Your Safety Read Before Operating START-UP ProceduresBefore START-UP Burners Water Lighting Instructions Millivolt SystemTo Turn OFF GAS to Appliance What to do if YOU Smell GAS Electronic Ignitions SystemsOperating Instructions Maintenance and Care Procedures Water Pressure SwitchAfter START-UP Visual InspectionAutomatic Chlorinators Chemical Feeders Pool & SPA Water ChemistryCold Weather Operation Winterizing the Pool & SPA Heater Receiving Equipment General SpecificationsStandardunitpolymerheaders Asme Unit Cast Iron Headers Installation Instructions Outdoorheaterinstallation Installations onlyOutdoor KIT Includes Indoor Heater InstallationIndoor KIT Includes Securing the TOP Panel Cover Indoor KIT only Installing the Clips Indoor & Outdoor KitsSecuring the TOP Panel Cover Outdoor KIT only Installing the TOP Cover Outdoor KIT only Specifications and Dimensions Combustion and Ventilation AIR Indoor Units OnlyVent Piping GAS Supply ConnectionsGAS Pressure Regulator GAS Pressure Adjustment LocationsPipe Sizing for GAS Connections Plumbing for Water Connections Flow RatesCast Iron Headrers Asme Models Unitherm Governor OperationExternal Auxiliary Bypass Valve Where Required Auxiliary Bypass Valve AdjustmentHeat Exchanger Pressure Drop Tables Heat Exchanger Reversal Procedure Polymer Header Models For Asme Models call your factory representativeMillivolt System Electrical WiringElectronic 240V Wiring Transformer Wiring 120V WiringIndependently Wiring Diagram Millivolt Mechanical Thermostat Wiring Diagram IID Atmospheric Wiring Diagram IID Low NOx Control Panel Removal General Location of Controlscontrol AdjustmentsMillivolt Controls Thermostat Control Operation Digital Thermostat ControlsFahrenheit vs Centigrade Reading a Fault DiagnosticsDisplay Definition Remote Operation Remote Control Installation and OperationActivating the Remote Remote Control Wiring Wire Remote Control On-OffPressure Switch Flame ROLL-OUT Safety SwitchPilot SAFETY- Millivolt Pilot SAFETY- ElectronicPilot Removal and Cleaning Burner Drawer RemovalGAS Valve Removal Main Burner and Orifice RemovalTubecleaningprocedure DesootingprocedureImmersion Well Replacement Unitherm Governor U.G. ReplacementSTART-UP Procedures BurneradjustmentBlower Adjustment Flame ROLL-OUT Safety SwitchPilot Removal Combustion FAN RemovalTroubleshooting Guide MechanicalforqualifiedservicepersonnelonlyElectrical Standing Pilot Millivolt Raypak Pool or SPA Heater Electrical Check with MV GAS ValveElectrical Electronic Ignition IID Troubleshooting For qualified technicians onlyDigital Control Logic Flow Chart RAYPAK, INC Replacement PartsEastman Avenue Oxnard, CA For Canada Illustrated Parts List Pilot Assemblies Page Page Page Page Page
Related manuals
Manual 46 pages 34.19 Kb

P-R185B to R-P405B, C-R185B to C-R405B, P-R185BL to P-R405BL, C-R185BL to C-R405BL, RP2100 specifications

Raypak is a leading manufacturer in the heating and cooling industry, renowned for its innovative products that cater to both residential and commercial sectors. One of its product lines, the RP2100 series, exemplifies cutting-edge technology and features designed to enhance efficiency and performance in pool heating systems.

The RP2100 models, particularly the P-R185B through R-P405B series, incorporate advanced heat exchanger technology, enabling them to offer exceptional heat transfer efficiency. The titanium heat exchangers are designed for durability and resistance against corrosion, particularly in saltwater environments, ensuring the longevity of the system. These units are engineered for both outdoor and indoor applications, with the versatility to adapt to various heating requirements.

In terms of energy efficiency, the RP2100 series boasts a high coefficient of performance (COP), making them cost-effective solutions for pool heating. They are equipped with digital thermostats that provide accurate temperature control, ensuring consistent heating capabilities while minimizing energy consumption. The inclusion of intelligent controls allows for seamless integration with existing systems and provides users with the ability to schedule heating cycles, further enhancing energy savings.

Moving beyond the RP2100 series, the C-R185B to C-R405B models are specifically tailored for commercial applications, combining robust performance with user-friendly features. These commercial heaters are designed to handle larger volumes of water and are built to withstand the rigors of high-traffic environments, such as resorts and sports complexes. Their vertical design optimizes space and promotes better airflow, which is crucial in high-demand scenarios.

The P-R185BL to P-R405BL and C-R185BL to C-R405BL models feature noise-reducing technology, making them suitable for residential settings where peace and quiet are paramount. They utilize advanced acoustic insulation materials that minimize operational noise without sacrificing performance.

In summary, the Raypak RP2100, P-R185B to R-P405B, C-R185B to C-R405B, P-R185BL to P-R405BL, and C-R185BL to C-R405BL series represent the pinnacle of innovation in pool heating solutions. With their durable construction, energy-efficient designs, and advanced technologies, these models are ideal for users seeking reliability, efficiency, and quiet operation in both residential and commercial environments. Investing in Raypak products ensures superior heating performance, longevity, and overall satisfaction.