Assembly / Installation | 4 |
IMPORTANT: To prevent leaks, be sure that the cleats on the corners of the basin gasket are up with the cover upside down (that is, not pressed into the sealing face of the cover).
Step 7 (See Figure 5)
Push the screws with their washers installed up through the holes in the rim of the cover and in the basin gasket (the cover will retain the screws).
Step 8 (See Figure 6)
•Align the cover with the discharge pipe and cords.
•Pull the cords through the
•Place the cover over the discharge pipe.
•Install the cords in the cord grommet
•Install the cord/grommet assembly in the
112" NPT
Discharge
112" NPT Vent
Cord Grommet
Inlet |
Discharge
Pump
4720 1004
Figure 6
Step 9 (See Figure 6)
Fasten the basin cover to the basin with the capscrews previously inserted in the cover (Step 7).
IMPORTANT: To prevent leaks, be sure the locating cleats on the corners of the basin gasket are outside the edges of the basin rim, not pressing against the rim.
INSTALLATION (See Figure 7)
The basin (system) should be located at the lowest place possible relative to the area to be drained.
NOTE: Make sure that the inlet of the
Thread pipes into fittings; don't go past end of threads.
112" NPT | 112" NPT |
Vent | Discharge |
|
151/8"
112" NPT Inlet
| 133/4" | |
1/3 HP | 12" | |
Pump | ||
| ||
| Vertical Float Switch | |
| 12" |
Figure 7 – Sink Pump System Dimensions
1.Install inlet pipe in opening as shown. Use RTV sealants or
Discharge
Vent
Pump
Figure 8 – Typical installation to remove air conditioner condensate or dehumidifier water
*Lake Chemical Co., Chicago, Illinois