Function Tests

Do Not Operate Unless:

You learn and practice the principles of safe machine operation contained in this operator's manual.

1Avoid hazardous situations.

2Always perform a pre-operation inspection.

3Always perform function tests prior to use.

Know and understand the function tests before going on to the next section.

4Inspect the workplace.

5Only use the machine as it was intended.

Fundamentals

The function tests are designed to discover any malfunctions before the machine is put into service. The operator must follow the step-by-step instructions to test all machine functions.

A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer’s specifications.

After repairs are completed, the operator must preform a pre-operation inspection and function tests again before putting the machine into service.

1Select a test area that is firm, level and free of obstruction.

At the Ground Controls

2Turn the key switch to ground control.

3Pull out the red Emergency Stop button to the on position.

Result: The beacon (if equipped) should flash.

Test Emergency Stop

4Push in the red Emergency Stop button to the off position.

Result: All ground and platform control functions should not operate.

5Pull out the red Emergency Stop button to the on position.

14

Genie Z-34/22 & Genie Z-34/22N

Part No.43654

Image 16
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Tip-over HazardsMaximum slope rating, stowed position Fall Hazards Collision Hazards Component Damage Hazard Damaged Machine HazardsBodily Injury Hazard Decal LegendBattery Safety Burn Hazards Component Damage HazardsExplosion Hazards Lifting HazardControls Platform Control PanelGround Control Panel Pre-operation Inspection FundamentalsPre-operation Inspection PRE-OPERATION InspectionMaintenance Maintenance Symbols LegendObserve and Obey Check the Hydraulic Oil LevelScheduled Maintenance Check the BatteriesAt the Ground Controls Function TestsTest Emergency Stop At the Platform Controls Test the Steering Test Machine FunctionsTest Drive and Braking Test the Drive Enable System Test Limited Drive SpeedMachines without lift/drive select switch Workplace Inspection Workplace InspectionOperating Instructions Only use the machine as it was intendedEmergency Stop Auxiliary ControlsOperation from Ground To Position PlatformTo Steer Operation from PlatformTo Drive Driving on a slope To determine the slope gradeDriving up a slope Driving Up/Down Slopes Drive/Brake Control TheoryDriving down a slope Low Battery Indicator Light Drive EnableAfter Each Use To Charge Battery Battery and Charger Instructions Observe and ObeyDry Battery Filling Charging Instructions Free-wheel Configuration for Winching Transport & Lifting InstructionsSecuring the Chassis Securing to Truck or Trailer for TransitSecuring the Platform Lifting Instructions Decals Decal InspectionGround Controls Side Chassis Platform Power Unit Specifications Drive speeds maximumBooms Mph Km/h Raised or extended 40 ft/40 sec 12.2 m/40 sec Genie Scandinavia