Genie Z-34, Z-22N Emergency Stop, Auxiliary Controls, Operation from Ground, To Position Platform

Page 23

Second Edition • Ninth Printing

Operator's Manual

 

 

 

 

Emergency Stop

Push in the red Emergency Stop button to the off position at the ground or platform controls to stop all machine functions.

Repair any function that operates when the red Emergency Stop button is pushed in.

Selecting and operating the ground controls will override the platform Red Emergency Stop button.

Auxiliary Controls

Use auxiliary power if the primary power source fails.

1Turn the key switch to ground or platform control.

2Pull out the red Emergency Stop button to the on position.

3Move the lift/drive select switch to the appropriate position (if equipped) when operating the auxiliary controls from the platform.

4Press down the foot switch when operating the auxiliary controls from the platform.

5Simultaneously hold the auxiliary power switch on and activate the desired function.

The boom, steer and drive functions will operate with auxiliary power.

OPERATING INSTRUCTIONS

Operation from Ground

1Turn the key switch to ground control.

2Pull out the red Emergency Stop button to the on position.

3Be sure both battery packs are connected before operating the machine.

To Position Platform

1Hold the function enable switch to either side.

2Move the appropriate toggle switch according to the markings on the control panel.

Drive and steer functions are not available from the ground controls.

Machines equipped with Platform Level Control Disable Function: The platform level toggle switch will not operate when the boom is raised past the drive speed limit switch.

Part No.43654

Genie Z-34/22 & Genie Z-34/22N

21

Image 23
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesTip-over Hazards Electrocution HazardsMaximum slope rating, stowed position Fall Hazards Collision Hazards Decal Legend Component Damage HazardDamaged Machine Hazards Bodily Injury HazardLifting Hazard Battery Safety Burn HazardsComponent Damage Hazards Explosion HazardsPlatform Control Panel ControlsGround Control Panel Fundamentals Pre-operation InspectionPRE-OPERATION Inspection Pre-operation InspectionCheck the Hydraulic Oil Level MaintenanceMaintenance Symbols Legend Observe and ObeyCheck the Batteries Scheduled MaintenanceTest Emergency Stop Function TestsAt the Ground Controls At the Platform Controls Test Drive and Braking Test Machine FunctionsTest the Steering Test Limited Drive Speed Test the Drive Enable SystemMachines without lift/drive select switch Workplace Inspection Workplace InspectionOnly use the machine as it was intended Operating InstructionsTo Position Platform Emergency StopAuxiliary Controls Operation from GroundTo Drive Operation from PlatformTo Steer To determine the slope grade Driving on a slopeDriving down a slope Driving Up/Down Slopes Drive/Brake Control TheoryDriving up a slope After Each Use Drive EnableLow Battery Indicator Light Dry Battery Filling Charging Instructions Battery and Charger Instructions Observe and ObeyTo Charge Battery Transport & Lifting Instructions Free-wheel Configuration for WinchingSecuring the Platform Securing to Truck or Trailer for TransitSecuring the Chassis Lifting Instructions Decal Inspection DecalsGround Controls Side Chassis Platform Power Unit Drive speeds maximum SpecificationsBooms Mph Km/h Raised or extended 40 ft/40 sec 12.2 m/40 sec Genie Scandinavia