Genie Z-34, Z-22 manual Battery and Charger Instructions Observe and Obey, To Charge Battery

Page 28

Operator's Manual

Second Edition • Ninth Printing

 

 

 

 

OPERATING INSTRUCTIONS

Battery and Charger Instructions

Observe and Obey:

Do not use an external charger or booster battery.

Charge the battery in a well-ventilated area.

Use proper AC input voltage for charging as indicated on the charger.

Use only a Genie authorized battery and charger.

To Charge Battery

1Be sure the batteries are connected before charging the batteries.

2Open the battery compartment. The compartment should remain open for the entire charging cycle.

3Remove the battery vent caps and check the battery acid level. If necessary, add only enough distilled water to cover the plates. Do not overfill prior to the charge cycle.

4Replace the battery vent caps.

5Connect the battery charger to a grounded AC circuit.

6Turn the battery charger on.

7The charger will indicate when the battery is fully charged.

8Check the battery acid level when the charging cycle is complete. Replenish with distilled water to the bottom of the fill tube. Do not overfill.

Dry Battery Filling and

Charging Instructions

1Remove the battery vent caps and permanently remove the plastic seal from the battery vent openings.

2Fill each cell with battery acid (electrolyte) until the level is sufficient to cover the plates.

Do not fill to the maximum level until the battery charge cycle is complete. Overfilling can cause the battery acid to overflow during charging. Neutralize battery acid spills with baking soda and water.

3Install the battery vent caps.

4Charge the battery.

5Check the battery acid level when the charging cycle is complete. Replenish with distilled water to the bottom of the fill tube. Do not overfill.

26

Genie Z-34/22 & Genie Z-34/22N

Part No.43654

Image 28
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Tip-over HazardsMaximum slope rating, stowed position Fall Hazards Collision Hazards Component Damage Hazard Damaged Machine HazardsBodily Injury Hazard Decal LegendBattery Safety Burn Hazards Component Damage HazardsExplosion Hazards Lifting HazardControls Platform Control PanelGround Control Panel Pre-operation Inspection FundamentalsPre-operation Inspection PRE-OPERATION InspectionMaintenance Maintenance Symbols LegendObserve and Obey Check the Hydraulic Oil LevelScheduled Maintenance Check the BatteriesAt the Ground Controls Function TestsTest Emergency Stop At the Platform Controls Test the Steering Test Machine FunctionsTest Drive and Braking Test the Drive Enable System Test Limited Drive SpeedMachines without lift/drive select switch Workplace Inspection Workplace InspectionOperating Instructions Only use the machine as it was intendedEmergency Stop Auxiliary ControlsOperation from Ground To Position PlatformTo Steer Operation from PlatformTo Drive Driving on a slope To determine the slope gradeDriving up a slope Driving Up/Down Slopes Drive/Brake Control TheoryDriving down a slope Low Battery Indicator Light Drive EnableAfter Each Use To Charge Battery Battery and Charger Instructions Observe and ObeyDry Battery Filling Charging Instructions Free-wheel Configuration for Winching Transport & Lifting InstructionsSecuring the Chassis Securing to Truck or Trailer for TransitSecuring the Platform Lifting Instructions Decals Decal InspectionGround Controls Side Chassis Platform Power Unit Specifications Drive speeds maximumBooms Mph Km/h Raised or extended 40 ft/40 sec 12.2 m/40 sec Genie Scandinavia