FUNCTION TESTS

Note: Perform the appropriate function tests for your control system. Determine whether the control panels on your machine match the ones below or the ones on page 20. Follow the step-by-step instructions below the pictures to test all machine functions

STOP

F

1

2

E

STOP

Ground Control Panels

STOP

Platform Control Panel

At the Ground Controls

1Insert the key and turn to ground control.

2Pull out the red Emergency Stop buttons at the ground and platform controls.

3Models with manual outriggers: Select an outrigger. Maintain a firm grasp on the outrigger. Pull the outrigger release handle and lower the outrigger. Be sure the outrigger lock pin is locked. Repeat the procedure for each of the remaining outriggers.

Adjust the outriggers to level the machine and raise the wheels slightly off the ground. Level the machine using only the outriggers. Use the bubble level to make sure the machine is level.

Models with hydraulic outriggers: Push and hold the yellow function enable button. Push and hold the auto level button or the individual outrigger buttons to lower the outriggers and level the machine. Level the machine using only the outriggers. Use the bubble level to make sure the machine is level.

Test Emergency Stop

4Push in the ground red Emergency Stop button to the off position.

Result: All ground and platform control functions should not operate.

5Pull out the red Emergency Stop button to the on position.

Test Outrigger Interlock

6Unscrew one leveling jack or use the leveling buttons to raise one outrigger off the ground.

Result: All boom functions should not operate.

7Return the leveling jack to the previous setting or use the leveling buttons to lower the outrigger.

8Repeat the procedure for each outrigger.

Test the Boom Functions

9Do not push a function enable button. Attempt to activate each boom function button.

Result: All boom functions should not operate.

10Push and hold the blue function enable button. Activate each boom function button.

Result: Primary boom up, primary boom extend, secondary boom up and turntable rotate right should all function.

11Push and hold the yellow function enable button. Activate each boom function button.

Result: Primary boom down, primary boom retract, secondary boom down and turntable rotate left should all function.

22

GenieTMZ-34/19

Part No. 97866

Image 24 Contents
Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Tip-over HazardsBodily Injury Hazard Collision Hazards Component Damage HazardsLifting Hazards Explosion and Fire HazardsTowing Hazards Decal LegendPersonnel Lifting Configuration Tip-over Hazards Material Lifting Configuration Collision HazardsFall Hazards Collision HazardBattery Safety Burn Hazards Explosion HazardsTip-over Hazard Lifting HazardControls Platform Control PanelStop Ground Control Panel manual outriggers Ground Control Panel hydraulic outriggers Stop Stop Pre-operation Inspection FundamentalsPre-operation Inspection PRE-OPERATION InspectionMaintenance Maintenance Symbols LegendObserve and Obey Check the Hydraulic Oil LevelMaintenance Check the Tires and Wheels Scheduled Maintenance Check the BatteriesSet up Function TestsAt the Ground Controls Test Emergency StopTest Outrigger Interlock At the Platform Controls Test the Boom FunctionsTest the Tilt Sensor Test the HornGround Control Panels Test Boom Functions and Function Enable Workplace Inspection Workplace InspectionOperating Instructions Only use the machine as it was intendedEmergency Stop Operation from GroundOperation from Platform To Position PlatformManual Lowering Manual Turntable RotationFall Protection TransportTowing Information Moving Machine Without a Tow VehicleBacking Up with Trailer If equipped with surge brake After Each Use Material Lifting Configuration Observe and Obey Material Lifting Configuration Set upBattery and Charger Instructions Observe and Obey Dry Battery Filling Charging InstructionsTo Charge Battery Voltage ConversionDecals Decal InspectionPower GroundControls SideSpecifications Ansi & CSAReporting Safety Defects Reporting Safety DefectsGenie Industries PO Box Redmond, WA