Second Edition · Third Printing | Operator's Manual |
|
|
|
|
Function Tests
Do Not Operate Unless:
You learn and practice the principles of safe machine operation contained in this operator's manual.
1Avoid hazardous situations.
2Always perform a
3Always perform function tests prior to use.
Know and understand the function tests before going on to the next section.
4Inspect the workplace.
5Only use the machine as it was intended.
Fundamentals
The function tests are designed to discover any malfunctions before the machine is put into service. The operator must follow the
A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer's specifications.
After repairs are completed, the operator must perform a
1Select a test area that is firm, level and free of obstruction.
At the Ground Controls
2Pull out the platform and ground red Emergency Stop button to the on position.
3Turn the key switch to ground control.
4Observe the diagnostic LED readout.
Result: LED should look like picture at right.
5Start the engine. See Operating Instructions section.
Test Emergency Stop
6Push in the ground red Emergency Stop button to the off position.
Result: The engine should turn off and no functions should operate.
7Pull out the red Emergency Stop button to the on position and restart the engine.
Test the Up/Down Functions
The audible warnings on this machine and the standard horn all come from the same central alarm. The horn is a constant tone. The descent alarm sounds at 60 beeps per minute. The alarm that goes off when the machine is not level sounds at 180 beeps per minute.
8Do not push and hold the function enable button and activate the platform up function.
Result: No function should operate.
Part No. 82233 | Genie | 17 |