Genie DPL-30S, DPL-25S, DPL-35S manual Pre-operation Inspection

Page 12

Operator’s Manual

Second Edition • First Printing

 

 

 

 

PRE-OPERATION INSPECTION

Pre-operation Inspection

oBe sure that the operator’s, safety and responsibilities manuals are complete, legible and in the storage container located in the platform.

oBe sure that all decals are legible and in place. See Decals section.

oCheck for battery fluid leaks and proper fluid level. Add distilled water if needed. See Maintenance section.

oCheck for hydraulic oil leaks and proper oil level. Add oil if needed. See Maintenance section.

Check the following components or areas for damage, improperly installed or missing parts and unauthorized modifications:

oElectrical components and wiring

oCoil cord (if equipped)

oHydraulic power unit, hoses, fittings and cylinders

oManual lowering lever

oPlatform end guard rail, platform side guard rails and platform entry gate

oGuard rail lock handles

oSequencing cables and pulleys

oLifting chains and idler wheels

oNuts, bolts and other fasteners

oMast and mast braces

oBreather cap

oOutriggers, leveling jacks and footpads

oGuard rail lift arm

oPlatform entry ladder

Check entire machine for:

oDents or damage

oCorrosion or oxidation

oCrack in welds or structural components

oInspect and clean battery terminals and all battery cable connections.

oBe sure that all structural and other critical components are present and all associated fasteners and pins are in place and properly tightened.

10

Genie DPL Super Series

Part No. 82799

Image 12
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessTip-over Hazards Fall Hazards Electrocution Hazards Collision HazardsComponent Damage Hazards Improper Use Hazard Damaged Machine HazardsBodily Injury Hazard Decal LegendBattery and Charger Safety DC Models Burn Hazards Explosion HazardsLifting Hazard Controls Platform ControlsPage Pre-operation Inspection Breather Cap AC & DC ModelsFundamentals Pre-operation Inspection Maintenance Observe and ObeyCheck the Battery DC Models Check the Hydraulic Oil Level AC and DC ModelsScheduled Maintenance Function Tests Function TestsTest Emergency Stop Test Outrigger Interlock Workplace Inspection Workplace InspectionOperating Instructions Setup Emergency StopPlatform Raise and Lower Platform Overload Indicator Light if equipped Manual LoweringAuxiliary Platform Lowering AC & DC Models Fall ProtectionBattery and Charger Instructions Observe and Obey To Charge BatteryDry Battery Filling Charging Instructions Transport and Lifting Instructions Loading the Machine With a ForkliftWinching the Machine onto a Flatbed Truck Lifting Instructions Transport and Lifting InstructionsDecals Inspection for Decals with WordsDecals Inspection for Decals with Symbols Decals Specifications Maximum capacityDistributed By