Genie DPL-30S, DPL-25S, DPL-35S Electrocution Hazards, Collision Hazards, Component Damage Hazards

Page 6

Operator’s Manual

Second Edition • First Printing

 

 

 

 

SAFETY RULES

Electrocution

Hazards

This machine is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Keep away from the machine if it contacts energized power lines or becomes electrically charged. Personnel on the ground or in the platform must not touch or operate the machine until the energized power lines are shut off.

Maintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

Voltage

Minimum Safe

 

Approach Distance

 

 

 

Phase to Phase

Feet

Meters

 

 

0 to 300V

Avoid Contact

 

 

 

300V to 50KV

10

3.05

 

 

 

50KV to 200KV

15

4.60

 

 

 

200KV to 350KV

20

6.10

 

 

 

350KV to 500KV

25

7.62

 

 

 

500KV to 750KV

35

10.67

 

 

 

750KV to 1000KV

45

13.72

 

 

 

Allow for platform movement, electrical line sway or sag and movement due to strong or gusty winds.

Do not use the machine as a ground for welding.

Do not operate the machine during lightning or storms.

Do not operate an AC powered machine or a DC battery charger unless using a 3-wire grounded extension cord connected to a grounded AC circuit. Do not alter or disable the 3-wire grounded plugs.

Collision Hazards

Operators must comply with employer, job site and governmental rules regarding the use of personal protective equipment.

Check the work area for overhead obstructions or other possible hazards.

Be aware of crushing hazards when grasping the platform side guard rails.

Do not lower the platform unless the area below is clear of personnel and obstructions.

Be careful when transporting on an incline.

Stay clear of descending platform.

Component Damage Hazards

Do not operate the machine unless a breather cap has been installed in the hydraulic reservoir. See the Pre-operation Inspection section for breather cap instructions.

Do not use the machine as an electrical ground for welding.

DC models: Do not operate the machine with a weak or overly discharged battery.

4

Genie DPL Super Series

Part No. 82799

Image 6
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessTip-over Hazards Fall Hazards Electrocution Hazards Collision HazardsComponent Damage Hazards Bodily Injury Hazard Improper Use HazardDamaged Machine Hazards Decal LegendBattery and Charger Safety DC Models Burn Hazards Explosion HazardsLifting Hazard Controls Platform ControlsPage Pre-operation Inspection Breather Cap AC & DC ModelsFundamentals Pre-operation Inspection Maintenance Observe and ObeyCheck the Battery DC Models Check the Hydraulic Oil Level AC and DC ModelsScheduled Maintenance Function Tests Function TestsTest Emergency Stop Test Outrigger Interlock Workplace Inspection Workplace InspectionOperating Instructions Setup Emergency StopPlatform Raise and Lower Auxiliary Platform Lowering AC & DC Models Platform Overload Indicator Light if equippedManual Lowering Fall ProtectionBattery and Charger Instructions Observe and Obey To Charge BatteryDry Battery Filling Charging Instructions Transport and Lifting Instructions Loading the Machine With a ForkliftWinching the Machine onto a Flatbed Truck Lifting Instructions Transport and Lifting InstructionsDecals Inspection for Decals with WordsDecals Inspection for Decals with Symbols Decals Specifications Maximum capacityDistributed By

DPL-30S, DPL-25S, DPL-35S specifications

The Genie DPL series of lift platforms includes the DPL-35S, DPL-25S, and DPL-30S models, known for their robust performance, innovative design, and user-friendly features. These machines are ideal for various applications, including maintenance, construction, and warehousing, providing efficient solutions for accessing heights with safety and ease.

The DPL-35S is distinguished by its impressive working height of up to 35 feet, making it suitable for tasks that require extended reach. This model comes equipped with a powerful electric drive system, ensuring smooth operation while minimizing noise levels. Its compact dimensions make it ideal for confined spaces, and the non-marking wheels allow for safe use on sensitive surfaces. The DPL-35S features a comfortable platform with ample space for tools and personnel, enhancing productivity during tasks.

Similarly, the DPL-25S offers a working height of 25 feet, providing an excellent combination of reach and maneuverability. It benefits from a lightweight design, which not only enhances portability but also ensures ease of transportation between job sites. The DPL-25S incorporates advanced safety features, including an automatic leveling system and safety guardrails, promoting secure work environments for operators.

The DPL-30S strikes a balance between the two models, offering a working height of 30 feet. This model is designed with robust materials that ensure reliability and durability even in demanding conditions. The DPL-30S supports various accessories, allowing for customization to meet specific job requirements. Its intuitive control system simplifies operation, making it accessible for both experienced and novice users alike.

All three models in the Genie DPL series utilize cutting-edge technologies that enhance performance and safety. The electric power system provides efficient operation while reducing emissions, contributing to environmentally friendly practices. The user-friendly controls allow for easy maneuverability, enabling operators to focus on their tasks without getting bogged down by complex mechanisms.

In summary, the Genie DPL-35S, DPL-25S, and DPL-30S lift platforms are engineered for versatility, safety, and efficiency in accessing elevated work areas. Their distinctive features, combined with robust technologies, make them essential tools for various industries, facilitating smoother workflows and improved productivity.