Second Edition • First Printing | Operator’s Manual |
|
|
|
|
6Be sure that all four interlock display lights at the ground controls are on.
7Use the bubble level and adjust the leveling jacks until the machine base is level.
8Rotate the platform guard rail locking handle and rotate the platform side guard rail to the upright position. Be sure the side guard rail locks in place. Repeat for the other side.
9Pull the ladder lock pins and rotate the ladder down. Be sure the ladder locks in place.
10Climb the ladder to enter the platform. Close and latch the platform entry gate and the platform end guard rail.
FUNCTION TESTS
Test Emergency Stop
11Twist to release the red Emergency Stop button at the platform controls.
12Push in the red Emergency Stop button at the ground controls to the off position.
13Push and hold the control activate button and rotate the up/down switch in the direction of intended travel.
Result: The up/down function should not operate.
14 Push in the red Emergency Stop button at the platform controls to the off position.
15 Pull out the red Emergency Stop button at the ground controls to the on position.
16Push and hold the control activate button and rotate the up/down switch in the direction of intended travel.
Result: The up/down function should not operate.
Part No. 82799 | Genie DPL Super Series | 15 |