6Be sure that all four interlock display lights at the ground controls are on.

7Use the bubble level and adjust the leveling jacks until the machine base is level.

8Rotate the platform guard rail locking handle and rotate the platform side guard rail to the upright position. Be sure the side guard rail locks in place. Repeat for the other side.

9Pull the ladder lock pins and rotate the ladder down. Be sure the ladder locks in place.

10Climb the ladder to enter the platform. Close and latch the platform entry gate and the platform end guard rail.

FUNCTION TESTS

Test Emergency Stop

11Twist to release the red Emergency Stop button at the platform controls.

12Push in the red Emergency Stop button at the ground controls to the off position.

13Push and hold the control activate button and rotate the up/down switch in the direction of intended travel.

Result: The up/down function should not operate.

14 Push in the red Emergency Stop button at the platform controls to the off position.

15 Pull out the red Emergency Stop button at the ground controls to the on position.

16Push and hold the control activate button and rotate the up/down switch in the direction of intended travel.

Result: The up/down function should not operate.

Part No. 82799

Genie DPL Super Series

15

Image 17
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesTip-over Hazards Fall Hazards Component Damage Hazards Electrocution HazardsCollision Hazards Damaged Machine Hazards Improper Use HazardBodily Injury Hazard Decal LegendLifting Hazard Battery and Charger Safety DC Models Burn HazardsExplosion Hazards Platform Controls ControlsPage Fundamentals Pre-operation InspectionBreather Cap AC & DC Models Pre-operation Inspection Observe and Obey Maintenance Check the Hydraulic Oil Level AC and DC Models Check the Battery DC ModelsScheduled Maintenance Function Tests Function TestsTest Emergency Stop Test Outrigger Interlock Workplace Inspection Workplace InspectionOperating Instructions Platform Raise and Lower SetupEmergency Stop Manual Lowering Platform Overload Indicator Light if equippedAuxiliary Platform Lowering AC & DC Models Fall ProtectionDry Battery Filling Charging Instructions Battery and Charger Instructions Observe and ObeyTo Charge Battery Winching the Machine onto a Flatbed Truck Transport and Lifting InstructionsLoading the Machine With a Forklift Transport and Lifting Instructions Lifting InstructionsInspection for Decals with Words DecalsDecals Inspection for Decals with Symbols Decals Maximum capacity SpecificationsDistributed By