Genie S-80 Check the Hydraulic Oil Level, Deutz F4L 1011F Engine Oil Capacity Including filter

Page 15

Second Edition · Fifth Printing

Operator's Manual

 

 

 

 

Deutz F4L 1011F Engine

 

Oil

capacity

(including filter)

8.5 quarts 8 liters

 

 

 

 

Oil

viscosity

requirements

 

 

 

below 60°F / 15.5°C (synthetic)

5W-30

 

 

-10°F to 90°F / -23°C to 32°C

10W-40

 

 

above -4°F / -34°C

15W-40

Engine oil should have properties of API classification CC/SE or CC/SF grades.

Units ship with 10-40 CC/SG.

Perkins 704-30 Engine

 

Oil

capacity

(including filter)

9.6 quarts 9 liters

 

 

 

 

Oil

viscosity

requirements

 

 

 

below 60°F / 15.5°C

15W-40

 

 

-10°F to 90°F / -23°C to 32°C

10W-30

 

 

above -4°F / -34°C

15W-40

Engine oil should have properties of API classification CF4 grade.

Units ship with 10-40 CC/SG.

MAINTENANCE

Check the Hydraulic Oil Level

Maintaining the hydraulic oil at the proper level is essential to machine operation. Improper hydraulic oil levels can damage hydraulic components. Daily checks allow the inspector to identify changes in oil level that might indicate the presence of hydraulic system problems.

1Be sure that the boom is in the stowed position, then visually inspect the sight gauge located on the side of the hydraulic oil tank. Add oil as needed.

Result: The hydraulic oil level should be within the top 2 inches (5 cm) of the sight gauge.

Hydraulic oil specifications

Hydraulic oil type

Dexron equivalent

 

 

 

Tank capacity

45

gallons

 

170

liters

 

 

 

Hydraulic system

55

gallons

(including tank)

208

liters

 

 

 

 

Part No. 43650

Genie S-80 & Genie S-85

13

Image 15
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesTip-over Hazards Electrocution HazardsMaximum allowable manual force CE Maximum allowable side force-ANSI & CSABodily Injury Hazard Fall HazardsComponent Damage Hazards Collision HazardsExplosion and Fire Hazards Damaged Machine HazardsDecal Legend Ground Control Panel ControlsPlatform Control Panel Controls Fundamentals Pre-operation InspectionPRE-OPERATION Inspection Pre-operation InspectionCheck the Engine Oil Level MaintenanceMaintenance Symbols Legend Observe and ObeyPerkins 704-30 Engine Oil Capacity Including filter Hydraulic oil specificationsCheck the Hydraulic Oil Level Deutz F4L 1011F Engine Oil Capacity Including filterFull mark Schedule Scheduled MaintenanceMaintenance Inspection Report Check the Tire PressureTest the Extendable Axles Function TestsAt the Ground Controls Test Emergency StopTest the Tilt Sensor Test the Machine FunctionsTest Auxiliary Controls Test the Service HornTest the Foot Switch At the Platform ControlsTest Machine Functions Test the SteeringTest Drive and Braking Test Limited Drive Speed Test the Drive Enable SystemTest the Lift/Drive Select Switch if equipped Work Place Inspection Work Place InspectionOnly use the machine as it was intended Operating InstructionsStarting the Engine Emergency StopTo Position Platform Auxiliary ControlsExtendable Axles Operation from GroundTo Drive Drive EnableOperation from Platform To SteerAfter Each Use Engine Idle Select rpmCheck Engine Light if equipped Stopping the EngineFree-wheel Configuration for Winching Transport InstructionsSecuring to Truck or Trailer for Transit Decals Decal InspectionDecal Description Quantity Engine Side Ground Controls Side Drive Chassis PlatformSpecifications ModelDrive speeds Distributed By