Emission Control System Warranty (ECS Warranty) for 1995 and later model year engines:

(a)Applicability: This warranty shall apply to 1995 and later model year engines. The ECS Warranty Period shall begin on the date the new engine or equipment is purchased by/delivered to its original, end-use purchaser/owner and shall con- tinue for 24 consecutive months thereafter.

(b)General Emissions Warranty Coverage: Generac warrants to the original, end-use purchaser/owner of the new engine or equipment and to each subsequent purchaser/owner that each of its engines is ...

(1)Designed, built and equipped so as to conform with all applicable regulations adopted by the CARB pursuant to its authority, and

(2)Free from defects in materials and workmanship which, at any time during the ECS Warranty Period, may cause a war- ranted emissions-related part to fail to be identical in all material respects to the part as described in the engine man- ufacturer’s application for certification.

(c)The ECS Warranty only pertains to emissions-related parts on your engine, as follows:

(1)Any warranted, emissions-related parts that are not scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by Generac according to Subsection (4) below. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.

(2)Any warranted, emissions-related part that is scheduled only for regular inspection as specified in the Owner’s Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary” shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.

(3)Any warranted, emissions-related part that is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by Generac according to Subsection

(4)below. Any such emissions-related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part.

(4)Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a Generac Authorized Warranty Service Facility.

(5)When the engine is inspected by a Generac Authorized Warranty Service Facility, the owner shall not be held responsi- ble for diagnostic costs if the repair is deemed warrantable.

(6)Generac shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of any emission-related part covered by the ECS Warranty.

(7)Throughout the ECS Warranty Period, Generac shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such emission-related parts.

(8)Any Generac authorized and approved emission-related replacement part may be used in the performance of any ECS Warranty maintenance or repairs and will be provided without charge to the owner. Such use shall not reduce Generac ECS Warranty obligations.

(9)Unapproved, add-on, modified, counterfeit and/or “grey market” parts may not be used to modify or repair a Generac engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. Generac shall not be held liable hereunder for failures of any warranted parts of a Generac engine caused by the use of such an unapproved, add-on, modified, counterfeit and/or “grey market” part.

EMISSION RELATED PARTS INCLUDE THE FOLLOWING:

1) Fuel Metering System:

3)

Ignition System including:

1.2) LPG/Natural Gas carburetion assembly and its internal

 

a) Spark plug

components.

 

b) Ignition module

a) Fuel controller (if so equipped)

4)

Catalytic Muffler Assembly (if so equipped) including:

b) Mixer and its gaskets (if so equipped)

 

a) Muffler gasket

c) Carburetor and its gaskets (if so equipped)

 

b) Exhaust manifold

d) Primary gas regulator (if so equipped)

5)

Crankcase Breather Assembly including:

 

e) LP liquid vaporizer (if so equipped)

a) Breather connection tube

2) Air Induction System including:

 

a) Intake pipe/manifold

 

b) Air cleaner

 

*Generac engine types covered by this warranty statement include the following:

1)Prepackaged Standby Generator

2)Auxiliary Power Unit (APU) Generator

3)Standby Generator

Part 2

Generac® Power Systems, Inc. 49

Image 51
Contents Liquid-cooled, Prepackaged Standby Generators Introduction Authorized Service Dealer Location‹ Operation and Maintenance ‹ HOW to Obtain ServiceIntroduction IFC Safety Rules General Hazards Electrical Hazards Generator AC Connection Systems Transfer SwitchGenerator Automatic System OperationEngine Protective Devices ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.2 High Coolant Temperature Switch ‹ 1.7.3 LOW Coolant Level SwitchLifting the Generator Unpacking‹ 1.10.2 Engine Specifications SpecificationsReconfiguring the Fuel System ‹ 1.10.1 Generator SpecificationsTorque Specifications Engine OIL RecommendationsCoolant Recommendations ‹ 2.1.1 Nfpa Standards Generator Mounting SupportBasic Standby Electric System Generator LocationGrounding the Generator Transfer Switch Start Signal ConnectionsEmergency Circuit Isolation Method Total Circuit Isolation Method‹ 2.11.1 Prior to Initial START-UP Battery InstallationPreparation Before START-UP ‹ 2.10.1 Vented BatteriesControl Console Components Using a Standard GTS Transfer SwitchWeekly Exercise Cycle Manual Transfer START-UP Automatic OperationEngine Heater Cooling System Overload Protection for Engine DC Electrical SystemChecking Fluid Levels ‹ 4.5.6 Perform Visual Inspection ‹ 4.5.11 Changing the Engine AIR Cleaner‹ 4.5.4 Inspect Cooling System ‹ 4.5.5 Check Engine Coolant Level‹ 4.5.13 Coolant Change Miscellaneous Maintenance‹ 4.6.4 Battery Replacement ‹ 4.6.3 Battery MaintenanceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsGuardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators Guardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators Installation Diagram Section DC-VR Customer Connection 120/240V 1-PHASE Electrical Data ASM Motor Stepper Housing Governor ConnectorConnector Interface Assembly Cover Connector HousingWasher Flat 5/16 Zinc BASE,MOUNTING 1.5L STNRD&ACSTCWasher Shakeproof EXT 5/16 STL Dampener VibrationRoof Cover Cable Weld Stud Under Roof ACSTC&STND Cmprtmnt 1.5L Assembly BASE-DOOR Ground WireGRD Wire Assy 99HSB Assembly Cover AccessWeld Stud Under Roof Panel for Access Cover Cable BRACE, Side 1.5L Mitsu ASSEMBLY,BASE-DOOR Ground WireROOF, ACSTC&STND Cmprtmnt 1.5L SUPPORT, Radiator 1.5L MitsuTo a Silksc Wire AssemblyScrew Hhtt M5-0.8 X 12 BP Washer Flat #10 ZincHardware ENGINE-1.5L Switch OIL PressureARM Adjust Alternator Ground Wire Starter16 7 Guard FAN 1.5L Modine Tank Coolant RecoveryRadiator 1.5L Venturi 1.5L ModineVapor Flange Fuel Inlet Cover AIR CleanerGASKET, AIR Cleaner Adapter Weldment Mounting BaseTo Engine Crankshaft Assy Rotor 20KW Housing BlowerAssy Rotor 10KW Assy Rotor 15KWBattery Post Cover RED+ ASSY,WIRE#16 REDBOOT, Battery Cable BRACKET, Battery Hold DownPIPE,EXHAUST 1.5L STNDRD&ACSTC Manifold Exhaust 1.5LNipple TOE 1.5NPTX5.5 BLK Iron Saddle 2 InchYour Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyThis Warranty Shall not Apply to the Following Warranty Schedule

0047210, 0047220, 0047230, 0047240, 0047250, 0047251, 0047252, 0047253, 0047260 specifications

Generac is renowned for its innovation in the power generation industry, and their range of generators—including models 0047210, 0047220, 0047230, 0047240, 0047250, 0047251, 0047252, 0047253, and 0047260—showcase advanced technologies and functionality that meet diverse power needs.

One of the standout features of these models is the use of Generac’s G-Force Engine, specifically designed for reliability and longevity. This engine is notorious for its durability, capable of handling demanding workloads and proving to be more efficient than typical engines found in similar generators. It provides quick start times, lower emissions, and is built to withstand extended operational cycles.

Another notable technology in these models is the Quiet-Test™ mode, which enables the generator to run at a lower RPM while it performs an exercise routine. This feature not only reduces noise during operation but also conserves fuel, making it an eco-friendly option that doesn’t compromise on performance.

The generators are equipped with advanced monitoring and control features, including the Mobile Link™ application compatibility. This allows users to monitor the status of their generator remotely via a smartphone or tablet, offering peace of mind and real-time access to the generator's operational functioning. This connectivity also enables the user to receive alerts and notifications about maintenance needs or when the generator is in need of attention.

In terms of design, these models boast a robust steel enclosure that offers superior protection against the elements, thereby enhancing durability and ensuring efficient operation regardless of weather conditions. The enclosures also come with a weather-resistant finish, making them suitable for outdoor installation.

Moreover, the generators feature a well-thought-out installation process with easily accessible controls and noise-reduction technology, which helps minimize disturbances for residential applications. They also offer multiple power outputs, catering to varied energy needs, from essential home appliances to larger devices.

Safety is a core consideration with Generac models, and features such as the automatic shutdown mechanism prevent overheating, ensuring operational safety during use. Coupled with an efficient fuel consumption rate, these generators stand out as impeccable solutions for power backup in homes and businesses alike.

The series exemplifies Generac’s commitment to excellence in power solutions, integrating user-friendly technology, efficient performance, and top-tier safety into compact, durable designs. Users can rely on models 0047210 to 0047260 for dependable power generation tailored to their specific needs.