Troubleshooting
Regarding the indicator lamps (continued)
POWER | LAMP | TEMP | Description | |
indicator | indicator | indicator | ||
| ||||
|
|
| The cooling fan is not operating. | |
Blinking |
|
| Please turn the power off, and allow the unit to cool | |
|
| down at least 20 minutes. After the projector has | ||
In Red |
| Blinking | ||
Turned | suffi ciently cooled down, please make confi rmation | |||
or | ||||
off | In Red | that no foreign matter has become caught in the fan, | ||
Lighting | ||||
|
| etc., and then turn the power on again. | ||
In Red |
|
| ||
|
| If the same indication is displayed after the treatment, | ||
|
|
| ||
|
|
| please contact your dealer or service company. | |
|
|
|
| |
|
|
| There is a possibility that the interior portion | |
|
|
| has become heated. | |
|
|
| Please turn the power off, and allow the unit to cool | |
Blinking |
|
| down at least 20 minutes. After the projector has | |
|
| suffi ciently cooled down, please make confi rmation of | ||
In Red |
|
| ||
Turned | Lighting | the following items, and then turn the power on again. | ||
or | ||||
off | In Red | • Is there blockage of the air passage aperture? | ||
Lighting | ||||
|
| • Is the air fi lter dirty? | ||
In Red |
|
| ||
|
| • Does the peripheral temperature exceed 35°C? | ||
|
|
| ||
|
|
| If the same indication is displayed after the treatment, | |
|
|
| please change the lamp by referring to the section | |
|
|
| “Lamp”. | |
|
|
|
| |
|
|
| There is a possibility that the interior portion | |
Lighting | Alternative | has become overcooled. | ||
Please use the unit within the usage temperature | ||||
In Green | blinking in Red | |||
parameters (5°C to 35°C). After the treatment, resent | ||||
|
|
| ||
|
|
| the power to ON. | |
|
|
|
| |
|
|
| It is time to clean the air filter, or there is no air | |
|
|
| filter. | |
Lighting | Simultaneous | Please immediately turn the power OFF, and clean | ||
or change the air fi lter by referring to the section “Air | ||||
In Green | blinking in Red | |||
Filter”. After cleaning or changed the lamp, please be | ||||
|
|
| ||
|
|
| sure to reset the fi lter timer. After the treatment, resent | |
|
|
| the power to ON. | |
|
|
|
|
38