NEC 151944 system manual System Conditions

Page 17

6.SYSTEM CONDITIONS

For providing the Remote PIM System to the NEAX2000 IVS, observe the following conditions:

(1)The main site must be the NEAX2000 IVS. The Small Platform System cannot be the main site. The main site must be a medium platform (320 ports) or a large platform (512 ports). The small platform (72 ports) cannot be used.

(2)The Remote PIM can be a PIM N-UB, a PIM Q-UA, or a PIM AB-A.

(3)The Remote PIM can be installed at a maximum of 1312 ft. (399 m) distance from the main site. Using line extension equipment (repeater, MUX etc.), the distance can be extended.

(4)A maximum of 23 lines/trunks can be accommodated in one Remote PIM.

(5)On the remote site, the line/trunk circuit cards can be used as same as the main site, except the CSI card for wireless system according to UTAM regulation. However, the application circuit cards cannot be used at the remote site. When providing the ILC card to the remote site, the ICH card must be installed on the main site.

(6)For the Remote PIM System, the installation procedures for modules, circuit cards and peripheral equipment are the same as those for the regular NEAX2000 IVS, except the DAIA card and the DAIB card installation and the BUS cable connection. Refer to the applicable manuals for detailed information.

(7)When the link between the main site and the remote site is lost, the system activates PFT (Power Failure Transfer) automatically on the remote site, if provided.

(8)The resident system programming cannot be set to the remote site while the main site can be set.

(9)When the LC cards that use an AP card directly (i.e., ILC requires ICH, and 4COTB requires 4RSTC.) If ILC or COTB are mounted in the Remote PIM, the T1 link between the main and remote sites must be configured as 64 Kbps with ESF and B8ZS.

(10)In the remote site, if the Remote PIM is a 72-port PIM or a 48-port PIM, when installing a 4-circuit card (LC, DLC, COT, etc.), assign a phantom DK00 to Level 4 and Level 6 of that LT slot. This assignment will shift the time slots over enabling the use of additional card slots. (This action is not required if the Remote PIM is a 64-port PIM.)

ND-46550 (E)CHAPTER 2

Page 9

Revision 2.0

Image 17
Contents NEC America, Inc Liability Disclaimer NEAX2000 IVS Table of Contents List of Figures List of Figures List of Tables This page is for your notes Reference Manuals Outline of this ManualChapter System Outline System DescriptionPIM PIM ConfigurationPIM Configuration 2shows the system configuration System ConfigurationRequired Equipment Required EquipmentSN1308 PIM P-A PIM Q-UA SN1420 PIMAB-ARMT PCM-0.3 CA System Capacity System CapacityDaia DAIA, 2 DaicSystem Conditions Time Slot Allocation Time Slot AllocationFor the switch settings This page is for your notes Precaution in Handling InstallationStatic Electricity Guard PBX Start Installation ProcedureSee Section See .2.6 See Section Location of Lamps, Switches, and Connectors see Figure Lamp Indications on PN-DAIA Card Switch Settings on PN-DAIA Card OFF Setting of control signal time slotNeutral grounding on the receiving line is not Mounting Location of Daia Card ND-46550 E Mounting of Daia CardPN-DAIC Card Switch Setting of Daic CardDown Switch Settings on PN-DAIC CardLamp Indications on PN-DAIC Card SW2 Dip SW When mounting this card on remote Mounting Location of Daic Card Main Site Mounting of Daic CardBUS-DAIA Cable Connection ND-46550 E BUS Cable Connection10 DAIA-DAIC Cable Connection 11 DAIA-DAIC Cable Connection ND-46550 Echapter Revision 12 DAIA-DAIC Cable Connection 13 DAIA-DAIC Cable Connection ND-46550 E 14 PN-DAIB Card Lamp Indications on PN-DAIB Card Switch Settings on PN-DAIB Card TS6 OFF TS7 Down 15 Mounting Location of Daib Card ND-46550 E Mounting of Daib Card16 Mounting Location of Daib Card Refer to , Section 18 Mounting Location of Daic Card Remote PIM 19 Mounting Location of Daic Card Remote PIM ND-46550 E 20 DAIB-DAIC Cable Connection Mounting of Line/Trunk Card on Small Platform PIM LTC Connector Accommodation Small PlatformLTC0 LTC122 Location of Each LEN Small Platform LTC0 Mounting of Line/Trunk Card on 1000 IVS PIM LTC Connector Accommodation 1000 IVS25 Location of Each LEN 1000 IVS ND-46550 E 26 LTC Connector Pin Arrangement 1000 IVS PIM N-UB LTC1 10 LTC Connector AccommodationMounting of Line/Trunk Card on PIM N UB 64 port PIM 28 Location of Each LEN PIM NUB LTC0 30shows an outline of a PFT PN-AUCA connection Power Failure Transfer PFT31 MDF Cross Connection for PFT PN-AUCA ND-46550 E 32shows an outline of a PFT PZ-8PFTA connection PFT0 Connector 34 Mounting PZ-8PFTA Card to PIM 35 PFT Connector Pin Assignment ND-46550 E 36 MDF Cross Connection for PFT PZ-8PFTA PFT1 Connector To Station to PN-4LC to C.O. Line to PN-4COT 37 DTI Cable Connection via LTC Connector PIM0 Daia AA0 BA0 AA1 BA1 LTC1 MDF 39 DTI Cable Connection via CN Connector Main Site DTI Connection at Remote Site MP Reset Daib Remedial Action on Each Lamp StatusPN-DAIA Daia PN-DAIB Daib PN-DAIC Daic This page is for your notes