NEC 151944 system manual Location of Each LEN 1000 IVS ND-46550 E

Page 57

When opposite DAIA card is set to FP No.1:

LEN

0191

0135

0143

0151

0159

 

0167

 

0175

0190

0134

0142

0150

0158

 

0166

 

0174

0189

0133

0141

0149

0157

 

0165

 

0173

0188

0132

0140

0148

0156

 

0164

 

0172

0187

0131

0139

0147

0155

0159

0163

0167

0171

0186

0130

0138

0146

0154

0158

0162

0166

0170

0185

0129

0137

0145

0153

0157

0161

0165

0169

0184

0128

0136

0144

0152

0156

0160

0164

0168

 

 

 

 

 

 

 

 

 

SLOT No.

LT00 LT01 LT02 LT03

LT04 LT05

LT06 LT07 LT08

 

Note 2

Note 3

Note 4

When opposite DAIA card is set to FP No.2:

LEN

0319

0263

0271

0279

0287

 

0295

 

0303

0318

0262

0270

0278

0286

 

0294

 

0302

0317

0261

0269

0277

0285

 

0293

 

0301

0316

0260

0268

0276

0284

 

0292

 

0300

0315

0259

0267

0275

0283

0287

0291

0295

0299

0314

0258

0266

0274

0282

0286

0290

0294

0298

0313

0257

0265

0273

0281

0285

0289

0293

0297

0312

0256

0264

0272

0280

0284

0288

0292

0296

 

 

 

 

 

 

 

 

 

SLOT No.

LT00 LT01 LT02 LT03

LT04 LT05

LT06 LT07 LT08

 

Note 2

Note 3

Note 4

When opposite DAIA card is set to FP No.3:

LEN

0447

0391

0399

0407

0415

 

0423

 

0431

0446

0390

0398

0406

0414

 

0422

 

0430

0445

0389

0397

0405

0413

 

0421

 

0429

0444

0388

0396

0404

0412

 

0420

 

0428

0443

0387

0395

0403

0411

0415

0419

0423

0427

0442

0386

0394

0402

0410

0414

0418

0422

0426

0441

0385

0393

0401

0409

0413

0417

0421

0425

0440

0384

0392

0400

0408

0412

0416

0420

0424

 

 

 

 

 

 

 

 

 

SLOT No.

LT00 LT01 LT02 LT03

LT04 LT05

LT06 LT07 LT08

 

Note 2

Note 3

Note 4

Note 1: A maximum of 44 line/trunks can be accommodated in one Remote PIM.

Note 2: Do not mount line/trunk circuit card with cabling in this slot; this slot has no connection to the MDF via the backplane (LTC cables).

Note 3: When an 8-port line/trunk card, which requires cabling to MDF, is mounted in Slot 04, Slot 05 must be left vacant or mounted with circuit cards* that do not interfere with the 8-port card mounted in LT04.

Note 4: When DAIC is mounted in slot LT07, slot LT06 must use 4-port Line/Trunk card.

* When an 8-port card is mounted in Slot 04, Slot 05 can only be mounted with the following card: PN-M03

Figure 3-25 Location of Each LEN (1000 IVS)

 

ND-46550 (E)

CHAPTER 3

 

Page 49

 

Revision 2.0

Image 57
Contents NEC America, Inc Liability Disclaimer NEAX2000 IVS Table of Contents List of Figures List of Figures List of Tables This page is for your notes Reference Manuals Outline of this ManualChapter System Outline System DescriptionPIM Configuration PIM ConfigurationPIM 2shows the system configuration System ConfigurationRequired Equipment Required EquipmentSN1308 PIM P-A PIM Q-UA SN1420 PIMAB-ARMT PCM-0.3 CA System Capacity System CapacityDaia DAIA, 2 DaicSystem Conditions Time Slot Allocation Time Slot AllocationFor the switch settings This page is for your notes Precaution in Handling InstallationStatic Electricity Guard PBX Start Installation ProcedureSee Section See .2.6 See Section Location of Lamps, Switches, and Connectors see Figure Lamp Indications on PN-DAIA Card Switch Settings on PN-DAIA Card OFF Setting of control signal time slotNeutral grounding on the receiving line is not Mounting Location of Daia Card ND-46550 E Mounting of Daia CardPN-DAIC Card Switch Setting of Daic CardSwitch Settings on PN-DAIC Card Lamp Indications on PN-DAIC CardDown SW2 Dip SW When mounting this card on remote Mounting Location of Daic Card Main Site Mounting of Daic CardBUS-DAIA Cable Connection ND-46550 E BUS Cable Connection10 DAIA-DAIC Cable Connection 11 DAIA-DAIC Cable Connection ND-46550 Echapter Revision 12 DAIA-DAIC Cable Connection 13 DAIA-DAIC Cable Connection ND-46550 E 14 PN-DAIB Card Lamp Indications on PN-DAIB Card Switch Settings on PN-DAIB Card TS6 OFF TS7 Down 15 Mounting Location of Daib Card ND-46550 E Mounting of Daib Card16 Mounting Location of Daib Card Refer to , Section 18 Mounting Location of Daic Card Remote PIM 19 Mounting Location of Daic Card Remote PIM ND-46550 E 20 DAIB-DAIC Cable Connection Mounting of Line/Trunk Card on Small Platform PIM LTC Connector Accommodation Small PlatformLTC0 LTC122 Location of Each LEN Small Platform LTC0 Mounting of Line/Trunk Card on 1000 IVS PIM LTC Connector Accommodation 1000 IVS25 Location of Each LEN 1000 IVS ND-46550 E 26 LTC Connector Pin Arrangement 1000 IVS 10 LTC Connector Accommodation Mounting of Line/Trunk Card on PIM N UB 64 port PIMPIM N-UB LTC1 28 Location of Each LEN PIM NUB LTC0 30shows an outline of a PFT PN-AUCA connection Power Failure Transfer PFT31 MDF Cross Connection for PFT PN-AUCA ND-46550 E 32shows an outline of a PFT PZ-8PFTA connection PFT0 Connector 34 Mounting PZ-8PFTA Card to PIM 35 PFT Connector Pin Assignment ND-46550 E 36 MDF Cross Connection for PFT PZ-8PFTA PFT1 Connector To Station to PN-4LC to C.O. Line to PN-4COT 37 DTI Cable Connection via LTC Connector PIM0 Daia AA0 BA0 AA1 BA1 LTC1 MDF 39 DTI Cable Connection via CN Connector Main Site DTI Connection at Remote Site MP Reset Remedial Action on Each Lamp Status PN-DAIA DaiaDaib PN-DAIB Daib PN-DAIC Daic This page is for your notes