NEC 151944 system manual Neutral grounding on the receiving line is not

Page 30

Table 3-2 Switch Settings on PN-DAIA Card (Continued)

SWITCH

SWITCH

SETTING

FUNCTION

CHECK

NAME

NUMBER

POSITION

 

 

 

SW3 (Dip SW)

1

ON

Set equalizer according to cable length between

 

 

 

 

 

 

 

 

 

system and CSU.

 

 

ON

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4

 

 

 

 

 

SW-1

 

SW-2

SW-3

CABLE LENGTH

 

 

 

 

 

 

2

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

ON

0 - 131.2 ft. (0 - 40 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

OFF

131.2 - 262.5 ft. (40 - 80 m)

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

OFF

ON

262.5 - 394 ft. (80 - 120 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

ON

 

ON

 

OFF

OFF

394 - 525 ft. (120 - 160 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

ON

ON

525 - 656 ft. (160 - 200 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

 

OFF

OFF

Signal is not sent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

OFF

Always set to OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPS (Jumper pin)

 

Right

For mounting this card on PIM1 ~ PIM7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left

For mounting this card on PIM0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPR (Jumper pin)

 

Right

Neutral grounding on the receiving line is provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left

Neutral grounding on the receiving line is not

 

 

 

 

 

 

 

 

 

provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Set the groove on the switch knob to the desired switch position.

Note 2: Since DAIA card acts like an FP, the SW1 for DAIA in FPs cannot be set to the same number.

Note 3: When power is on, flip MB switch to ON (UP position) before plugging/unplugging the circuit card.

Note 4: When the clock signal from a master office is supplied via the line between the Main Site and the Remote Site, set the SW1-1 and SW1-2 according to settings in Table 3-3.In this case, DAIA cards (DAIA0, DAIA1) must be mounted in PIM0.

Table 3-3 Switch Settings When Clock Signal Supplied From Master Office

 

 

DAIA0

DAIA1

DAIA2

 

CONDITIONS

 

 

 

 

 

 

 

REMARKS

SW1-1

SW1-2

SW1-1

SW1-2

SW1-1

SW1-2

 

 

 

 

 

 

 

 

 

 

 

Only one DAIA

ON

 

OFF

-

-

-

-

Clock signal is sent to

card is provided.

 

 

 

 

 

 

 

PLO0 of MP card via

 

 

 

 

 

 

 

 

supply route 0 (DAIA0).

 

 

 

 

 

 

 

 

 

Two or three DAIA

ON

 

OFF

OFF

ON

OFF

OFF

Clock signal supply route

cards are provided.

 

 

 

 

 

 

 

is automatically changed

 

 

 

 

 

 

 

 

to route 1 (DAIA1) if

 

 

 

 

 

 

 

 

transmission line failure

 

 

 

 

 

 

 

 

occurs on supply route 0.

 

 

 

 

 

 

 

 

 

CHAPTER 3

ND-46550 (E)

Page 22

Revision 2.0

Image 30
Contents NEC America, Inc Liability Disclaimer NEAX2000 IVS Table of Contents List of Figures List of Figures List of Tables This page is for your notes Outline of this Manual Reference ManualsChapter System Description System OutlinePIM Configuration PIM ConfigurationPIM System Configuration 2shows the system configurationSN1308 PIM P-A PIM Q-UA Required EquipmentRequired Equipment SN1420 PIMAB-ARMT PCM-0.3 CA Daia System CapacitySystem Capacity DAIA, 2 DaicSystem Conditions Time Slot Allocation Time Slot AllocationFor the switch settings This page is for your notes Installation Precaution in HandlingStatic Electricity Guard PBX Installation Procedure StartSee Section See .2.6 See Section Location of Lamps, Switches, and Connectors see Figure Lamp Indications on PN-DAIA Card Switch Settings on PN-DAIA Card Setting of control signal time slot OFFNeutral grounding on the receiving line is not Mounting of Daia Card Mounting Location of Daia Card ND-46550 ESwitch Setting of Daic Card PN-DAIC CardSwitch Settings on PN-DAIC Card Lamp Indications on PN-DAIC CardDown SW2 Dip SW When mounting this card on remote Mounting of Daic Card Mounting Location of Daic Card Main SiteBUS Cable Connection BUS-DAIA Cable Connection ND-46550 E10 DAIA-DAIC Cable Connection 11 DAIA-DAIC Cable Connection ND-46550 Echapter Revision 12 DAIA-DAIC Cable Connection 13 DAIA-DAIC Cable Connection ND-46550 E 14 PN-DAIB Card Lamp Indications on PN-DAIB Card Switch Settings on PN-DAIB Card TS6 OFF TS7 Down Mounting of Daib Card 15 Mounting Location of Daib Card ND-46550 E16 Mounting Location of Daib Card Refer to , Section 18 Mounting Location of Daic Card Remote PIM 19 Mounting Location of Daic Card Remote PIM ND-46550 E 20 DAIB-DAIC Cable Connection LTC0 LTC Connector Accommodation Small PlatformMounting of Line/Trunk Card on Small Platform PIM LTC122 Location of Each LEN Small Platform LTC0 LTC Connector Accommodation 1000 IVS Mounting of Line/Trunk Card on 1000 IVS PIM25 Location of Each LEN 1000 IVS ND-46550 E 26 LTC Connector Pin Arrangement 1000 IVS 10 LTC Connector Accommodation Mounting of Line/Trunk Card on PIM N UB 64 port PIMPIM N-UB LTC1 28 Location of Each LEN PIM NUB LTC0 Power Failure Transfer PFT 30shows an outline of a PFT PN-AUCA connection31 MDF Cross Connection for PFT PN-AUCA ND-46550 E 32shows an outline of a PFT PZ-8PFTA connection PFT0 Connector 34 Mounting PZ-8PFTA Card to PIM 35 PFT Connector Pin Assignment ND-46550 E 36 MDF Cross Connection for PFT PZ-8PFTA PFT1 Connector To Station to PN-4LC to C.O. Line to PN-4COT 37 DTI Cable Connection via LTC Connector PIM0 Daia AA0 BA0 AA1 BA1 LTC1 MDF 39 DTI Cable Connection via CN Connector Main Site DTI Connection at Remote Site MP Reset Remedial Action on Each Lamp Status PN-DAIA DaiaDaib PN-DAIB Daib PN-DAIC Daic This page is for your notes