NEC 151944 system manual DTI Cable Connection via CN Connector Main Site

Page 72

(2)When using CN connector on DAIA Card

Connect the cable to a CSU or directly to the Remote PIM via the CN connector on the DAIA/DAIC card as shown in Figure 3-39.Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same manner as the DAIA-DIAB connection.

BWB

MAIN PIM

DAIA/

CN

DAIC

 

TWISTED-PAIR CABLE (SHIELD TYPE)

MDF

CSU

 

 

Note 1

 

MAX.656 ft. (200 m)

 

 

 

(0.65Φ cable)

 

DAIA/DAIC

MDF

 

 

CN

 

 

 

 

 

SEND

 

 

 

 

 

 

 

 

 

 

 

BA1

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

TB

 

 

 

 

 

 

 

 

 

 

 

AA1

3

 

 

 

 

 

 

 

TA

 

TO CSU/REMOTE PIM

 

BA0

2

 

 

 

 

 

 

 

RB

 

 

 

 

 

 

 

 

 

 

 

 

AA0

1

 

 

 

 

 

 

 

RA

 

 

 

 

 

 

 

 

 

 

 

 

RECEIVE

 

 

 

 

 

 

 

 

 

 

 

CN CONNECTOR

 

 

 

 

 

 

 

 

 

TB

TA

RB

RA

Note 1: When the Remote PIM is directly connected without CSU, maximum distance is 1312 ft. (400 m) between the Main PIM and the Remote PIM.

Note 2: When the DAIA card is mounted in the MP/FP slot, be sure to connect the cable to the CN con- nector on the DAIA card.

 

Figure 3-39 DTI Cable Connection via CN Connector (Main Site)

CHAPTER 3

ND-46550 (E)

Page 64

 

Revision 2.0

 

Image 72
Contents NEC America, Inc Liability Disclaimer NEAX2000 IVS Table of Contents List of Figures List of Figures List of Tables This page is for your notes Outline of this Manual Reference ManualsChapter System Description System OutlinePIM Configuration PIM ConfigurationPIM System Configuration 2shows the system configurationRequired Equipment Required EquipmentSN1308 PIM P-A PIM Q-UA SN1420 PIMAB-ARMT PCM-0.3 CA System Capacity System CapacityDaia DAIA, 2 DaicSystem Conditions Time Slot Allocation Time Slot AllocationFor the switch settings This page is for your notes Installation Precaution in HandlingStatic Electricity Guard PBX Installation Procedure StartSee Section See .2.6 See Section Location of Lamps, Switches, and Connectors see Figure Lamp Indications on PN-DAIA Card Switch Settings on PN-DAIA Card Setting of control signal time slot OFFNeutral grounding on the receiving line is not Mounting of Daia Card Mounting Location of Daia Card ND-46550 ESwitch Setting of Daic Card PN-DAIC CardSwitch Settings on PN-DAIC Card Lamp Indications on PN-DAIC CardDown SW2 Dip SW When mounting this card on remote Mounting of Daic Card Mounting Location of Daic Card Main SiteBUS Cable Connection BUS-DAIA Cable Connection ND-46550 E10 DAIA-DAIC Cable Connection 11 DAIA-DAIC Cable Connection ND-46550 Echapter Revision 12 DAIA-DAIC Cable Connection 13 DAIA-DAIC Cable Connection ND-46550 E 14 PN-DAIB Card Lamp Indications on PN-DAIB Card Switch Settings on PN-DAIB Card TS6 OFF TS7 Down Mounting of Daib Card 15 Mounting Location of Daib Card ND-46550 E16 Mounting Location of Daib Card Refer to , Section 18 Mounting Location of Daic Card Remote PIM 19 Mounting Location of Daic Card Remote PIM ND-46550 E 20 DAIB-DAIC Cable Connection LTC Connector Accommodation Small Platform Mounting of Line/Trunk Card on Small Platform PIMLTC0 LTC122 Location of Each LEN Small Platform LTC0 LTC Connector Accommodation 1000 IVS Mounting of Line/Trunk Card on 1000 IVS PIM25 Location of Each LEN 1000 IVS ND-46550 E 26 LTC Connector Pin Arrangement 1000 IVS 10 LTC Connector Accommodation Mounting of Line/Trunk Card on PIM N UB 64 port PIMPIM N-UB LTC1 28 Location of Each LEN PIM NUB LTC0 Power Failure Transfer PFT 30shows an outline of a PFT PN-AUCA connection31 MDF Cross Connection for PFT PN-AUCA ND-46550 E 32shows an outline of a PFT PZ-8PFTA connection PFT0 Connector 34 Mounting PZ-8PFTA Card to PIM 35 PFT Connector Pin Assignment ND-46550 E 36 MDF Cross Connection for PFT PZ-8PFTA PFT1 Connector To Station to PN-4LC to C.O. Line to PN-4COT 37 DTI Cable Connection via LTC Connector PIM0 Daia AA0 BA0 AA1 BA1 LTC1 MDF 39 DTI Cable Connection via CN Connector Main Site DTI Connection at Remote Site MP Reset Remedial Action on Each Lamp Status PN-DAIA DaiaDaib PN-DAIB Daib PN-DAIC Daic This page is for your notes