NEC 151944 system manual Setting of control signal time slot, Off

Page 29

Table 3-2 Switch Settings on PN-DAIA Card (Continued)

SWITCH

SWITCH

SETTING

FUNCTION

CHECK

NAME

NUMBER

POSITION

 

 

 

SW2 (Dip SW)

1

ON

Control channel signaling data transmission speed:

 

 

 

 

 

 

48 Kbps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

1 2 3 4 5 6 7 8

 

 

OFF

Control channel signaling data transmission speed:

 

 

 

 

 

 

 

 

 

 

64 Kbps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

ON

DTI frame configuration: 12-Multi Frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

DTI frame configuration: 24-Multi Frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

ON

Line code: AMI with ZCS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Line code: B8ZS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

ON

Setting of control signal time slot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

SWITCH NUMBER

 

 

TIME SLOT

 

 

 

 

 

 

 

 

4

5

 

6

7

8

 

NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

ON

 

OFF

ON

 

ON

ON

ON

 

TS1

 

 

 

 

 

 

ON

OFF

 

ON

ON

ON

 

TS2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

OFF

 

ON

ON

ON

 

TS3

 

 

 

 

 

 

OFF

 

ON

ON

 

OFF

ON

ON

 

TS4

 

 

 

 

 

 

 

 

OFF

ON

 

OFF

ON

ON

 

TS5

 

 

 

 

 

 

 

 

ON

OFF

 

OFF

ON

ON

 

TS6

 

 

 

 

 

6

ON

 

 

 

 

 

OFF

OFF

 

OFF

ON

ON

 

TS7

 

 

 

 

 

 

 

 

ON

ON

 

ON

OFF

ON

 

TS8

 

 

 

 

 

 

 

 

OFF

ON

 

ON

OFF

ON

 

TS9

 

 

 

 

 

 

OFF

 

 

 

 

 

 

ON

OFF

 

ON

OFF

ON

 

TS10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

OFF

 

ON

OFF

ON

 

TS11

 

 

 

 

 

7

ON

 

ON

ON

 

OFF

OFF

ON

 

TS12

 

 

 

 

 

 

 

 

OFF

ON

 

OFF

OFF

ON

 

TS13

 

 

 

 

 

 

 

 

ON

OFF

 

OFF

OFF

ON

 

TS14

 

 

 

 

 

 

OFF

 

 

 

 

 

 

OFF

OFF

 

OFF

OFF

ON

 

TS15

 

 

 

 

 

 

 

 

ON

ON

 

ON

ON

OFF

 

TS16

 

 

 

 

 

 

 

 

OFF

ON

 

ON

ON

OFF

 

TS17

 

 

 

 

 

8

ON

 

 

 

 

 

ON

OFF

 

ON

ON

OFF

 

TS18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

OFF

 

ON

ON

OFF

 

TS19

 

 

 

 

 

 

OFF

 

OFF

OFF

 

OFF

ON

OFF

 

TS23

 

*Time slot number 0, 20, 21, and 22 (TS0/20/21/22) cannot be used for control signal.

**This setting must be identical with the opposite DAIB card.

ND-46550 (E)CHAPTER 3

Page 21

Revision 2.0

Image 29
Contents NEC America, Inc Liability Disclaimer NEAX2000 IVS Table of Contents List of Figures List of Figures List of Tables This page is for your notes Reference Manuals Outline of this ManualChapter System Outline System DescriptionPIM PIM ConfigurationPIM Configuration 2shows the system configuration System ConfigurationRequired Equipment Required EquipmentSN1308 PIM P-A PIM Q-UA SN1420 PIMAB-ARMT PCM-0.3 CA System Capacity System CapacityDaia DAIA, 2 DaicSystem Conditions Time Slot Allocation Time Slot AllocationFor the switch settings This page is for your notes Precaution in Handling InstallationStatic Electricity Guard PBX Start Installation ProcedureSee Section See .2.6 See Section Location of Lamps, Switches, and Connectors see Figure Lamp Indications on PN-DAIA Card Switch Settings on PN-DAIA Card OFF Setting of control signal time slotNeutral grounding on the receiving line is not Mounting Location of Daia Card ND-46550 E Mounting of Daia CardPN-DAIC Card Switch Setting of Daic CardDown Switch Settings on PN-DAIC CardLamp Indications on PN-DAIC Card SW2 Dip SW When mounting this card on remote Mounting Location of Daic Card Main Site Mounting of Daic CardBUS-DAIA Cable Connection ND-46550 E BUS Cable Connection10 DAIA-DAIC Cable Connection 11 DAIA-DAIC Cable Connection ND-46550 Echapter Revision 12 DAIA-DAIC Cable Connection 13 DAIA-DAIC Cable Connection ND-46550 E 14 PN-DAIB Card Lamp Indications on PN-DAIB Card Switch Settings on PN-DAIB Card TS6 OFF TS7 Down 15 Mounting Location of Daib Card ND-46550 E Mounting of Daib Card16 Mounting Location of Daib Card Refer to , Section 18 Mounting Location of Daic Card Remote PIM 19 Mounting Location of Daic Card Remote PIM ND-46550 E 20 DAIB-DAIC Cable Connection Mounting of Line/Trunk Card on Small Platform PIM LTC Connector Accommodation Small PlatformLTC0 LTC122 Location of Each LEN Small Platform LTC0 Mounting of Line/Trunk Card on 1000 IVS PIM LTC Connector Accommodation 1000 IVS25 Location of Each LEN 1000 IVS ND-46550 E 26 LTC Connector Pin Arrangement 1000 IVS PIM N-UB LTC1 10 LTC Connector AccommodationMounting of Line/Trunk Card on PIM N UB 64 port PIM 28 Location of Each LEN PIM NUB LTC0 30shows an outline of a PFT PN-AUCA connection Power Failure Transfer PFT31 MDF Cross Connection for PFT PN-AUCA ND-46550 E 32shows an outline of a PFT PZ-8PFTA connection PFT0 Connector 34 Mounting PZ-8PFTA Card to PIM 35 PFT Connector Pin Assignment ND-46550 E 36 MDF Cross Connection for PFT PZ-8PFTA PFT1 Connector To Station to PN-4LC to C.O. Line to PN-4COT 37 DTI Cable Connection via LTC Connector PIM0 Daia AA0 BA0 AA1 BA1 LTC1 MDF 39 DTI Cable Connection via CN Connector Main Site DTI Connection at Remote Site MP Reset Daib Remedial Action on Each Lamp StatusPN-DAIA Daia PN-DAIB Daib PN-DAIC Daic This page is for your notes