NEC 151944 system manual LTC0

Page 55

 

LTC0

 

(FP1) (FP2) (FP3)

26

 

1

 

LEN0128 /0256 /0384

27

 

2

 

0129 /0257 /0385

28

 

3

 

0130 /0258 /0386

29

 

4

 

0131 /0259 /0387

30

 

5

 

0132 /0260 /0388

31

 

6

 

0133 /0261 /0389

32

 

7

 

0134 /0262 /0390

33

 

8

 

0135 /0263 /0391

34

 

9

 

0136 /0264 /0392

35

 

10

 

0137 /0265 /0393

36

 

11

 

0138 /0266 /0394

37

 

12

 

0139 /0267 /0395

38

 

13

 

0140 /0268 /0396

39

 

14

 

0141 /0269 /0397

40

 

15

 

0142 /0270 /0398

41

 

16

 

0143 /0271 /0399

42

 

17

 

0144 /0272 /0400

43

 

18

 

0145 /0273 /0401

44

 

19

 

0146 /0274 /0402

45

 

20

 

0147 /0275 /0403

46

 

21

 

0148 /0276 /0404

47

 

22

 

0149 /0277 /0405

48

 

23

 

0150 /0278 /0406

49

 

24

 

LEN0151 /0279 /0407

50

MN

25

MJ

 

 

LTC2

 

(FP1) (FP2) (FP3)

 

 

 

 

 

26

 

1

 

LEN0176 /0304 /0432

27

 

2

 

0177 /0305 /0433

28

 

3

 

0178 /0306 /0434

29

 

4

 

0179 /0307 /0435

30

 

5

 

0180 /0308 /0436

31

 

6

 

0181 /0309 /0437

32

 

7

 

0182 /0310 /0438

33

 

8

 

0183 /0311 /0439

34

 

9

 

0184 /0312 /0440

35

 

10

 

0185 /0313 /0441

36

 

11

 

0186 /0314 /0442

37

 

12

 

0187 /0315 /0443

38

 

13

 

0188 /0316 /0444

39

 

14

 

0189 /0317 /0445

40

 

15

 

0190 /0318 /0446

41

 

16

 

LEN0191 /0319 /0447

42

 

17

 

 

43

 

18

 

 

44

 

19

 

 

45

 

20

 

 

46

 

21

 

 

47

 

22

 

 

48

 

23

 

 

49

 

24

 

 

50

 

25

 

 

LT00

LT01

LT02

LT06

LT07

 

LTC1

 

(FP1) (FP2) (FP3)

26

 

1

 

LEN0152 /0280 /0408

27

 

2

 

0153

/0281 /0409

28

 

3

 

0154

/0282 /0410

29

 

4

 

0155

/0283 /0411

30

 

5

 

0156

/0284 /0412

31

 

6

 

0157

/0285 /0413

32

 

7

 

0158

/0286 /0414

33

 

8

 

0159

/0287 /0415

34

 

9

 

0160

/0288 /0416

35

 

10

 

0161

/0289 /0417

36

 

11

 

0162

/0290 /0418

37

 

12

 

0163

/0291 /0419

38

 

13

 

0164

/0292 /0420

39

 

14

 

0165

/0293 /0421

40

 

15

 

0166

/0294 /0422

41

 

16

 

0167

/0295 /0423

42

 

17

 

0168

/0296 /0424

43

 

18

 

0169

/0297 /0425

44

 

19

 

0170

/0298 /0426

45

 

20

 

0171

/0299 /0427

46

 

21

 

0172

/0300 /0428

47

 

22

 

0173

/0301 /0429

48

 

23

 

0174

/0302 /0430

49

 

24

 

LEN0175 /0303 /0431

50

 

25

 

 

 

LT03

LT04

LT05

Figure 3-23 LTC Connector Pin Arrangement (Small Platform)

ND-46550 (E)CHAPTER 3

Page 47

Revision 2.0

Image 55
Contents NEC America, Inc Liability Disclaimer NEAX2000 IVS Table of Contents List of Figures List of Figures List of Tables This page is for your notes Reference Manuals Outline of this ManualChapter System Outline System DescriptionPIM Configuration PIM ConfigurationPIM 2shows the system configuration System ConfigurationSN1420 PIMAB-A Required EquipmentRequired Equipment SN1308 PIM P-A PIM Q-UARMT PCM-0.3 CA DAIA, 2 Daic System CapacitySystem Capacity DaiaSystem Conditions Time Slot Allocation Time Slot AllocationFor the switch settings This page is for your notes Precaution in Handling InstallationStatic Electricity Guard PBX Start Installation ProcedureSee Section See .2.6 See Section Location of Lamps, Switches, and Connectors see Figure Lamp Indications on PN-DAIA Card Switch Settings on PN-DAIA Card OFF Setting of control signal time slotNeutral grounding on the receiving line is not Mounting Location of Daia Card ND-46550 E Mounting of Daia CardPN-DAIC Card Switch Setting of Daic CardLamp Indications on PN-DAIC Card Switch Settings on PN-DAIC CardDown SW2 Dip SW When mounting this card on remote Mounting Location of Daic Card Main Site Mounting of Daic CardBUS-DAIA Cable Connection ND-46550 E BUS Cable Connection10 DAIA-DAIC Cable Connection 11 DAIA-DAIC Cable Connection ND-46550 Echapter Revision 12 DAIA-DAIC Cable Connection 13 DAIA-DAIC Cable Connection ND-46550 E 14 PN-DAIB Card Lamp Indications on PN-DAIB Card Switch Settings on PN-DAIB Card TS6 OFF TS7 Down 15 Mounting Location of Daib Card ND-46550 E Mounting of Daib Card16 Mounting Location of Daib Card Refer to , Section 18 Mounting Location of Daic Card Remote PIM 19 Mounting Location of Daic Card Remote PIM ND-46550 E 20 DAIB-DAIC Cable Connection LTC1 LTC Connector Accommodation Small PlatformMounting of Line/Trunk Card on Small Platform PIM LTC022 Location of Each LEN Small Platform LTC0 Mounting of Line/Trunk Card on 1000 IVS PIM LTC Connector Accommodation 1000 IVS25 Location of Each LEN 1000 IVS ND-46550 E 26 LTC Connector Pin Arrangement 1000 IVS Mounting of Line/Trunk Card on PIM N UB 64 port PIM 10 LTC Connector AccommodationPIM N-UB LTC1 28 Location of Each LEN PIM NUB LTC0 30shows an outline of a PFT PN-AUCA connection Power Failure Transfer PFT31 MDF Cross Connection for PFT PN-AUCA ND-46550 E 32shows an outline of a PFT PZ-8PFTA connection PFT0 Connector 34 Mounting PZ-8PFTA Card to PIM 35 PFT Connector Pin Assignment ND-46550 E 36 MDF Cross Connection for PFT PZ-8PFTA PFT1 Connector To Station to PN-4LC to C.O. Line to PN-4COT 37 DTI Cable Connection via LTC Connector PIM0 Daia AA0 BA0 AA1 BA1 LTC1 MDF 39 DTI Cable Connection via CN Connector Main Site DTI Connection at Remote Site MP Reset PN-DAIA Daia Remedial Action on Each Lamp StatusDaib PN-DAIB Daib PN-DAIC Daic This page is for your notes