Diagnostics

Malfunction

 

 

Check

 

 

 

The projector does not change cycles when

1.

The CYCLE LEVER and the RATCHET

using a DISSOLVE CONTROL; the REMOTE

 

PLATE are dirty.

CONTROL and CONTROL PANEL BUTTONS

 

Clean and apply lubricant SUPER

operate correctly.

 

 

 

LUBE TL-4276 to the CYCLE LEVER

 

 

 

 

 

 

and RATCHET PLATE.

 

2.

If this does not correct the malfunction:

 

 

• Install a new CAM SHAFT ASSEMBLY.

 

 

 

SLIDE TRAY does not advance smoothly.

1.

Check the SLIDE TRAY LATCH for correct

 

 

alignment.

 

2.

Operate the projector in the forward

 

 

direction.

 

 

• Check that the INDEXER LEVER

 

 

 

ASSEMBLY is in the correct alignment

 

 

 

with the holes at positions A and B.

 

 

Do the adjustment for the INDEXER

 

 

 

LEVER ASSEMBLY.

 

 

Check the condition of the LOCATOR

 

 

 

LEVER, it should not be bent.

 

 

Check the height of the SLIDE LIFT

 

 

 

LEVER; the lower corner of the LIFT

 

 

 

LEVER RAMP is parallel with the TOP

 

 

 

HOUSING. If the height is not correct,

 

 

 

do the adjustment for the MANUAL and

 

 

 

POWER SLIDE LIFT LEVER

 

 

 

ECCENTRICS.

 

 

 

SLIDE TRAY advances when “REVERSE” is

1.

Do the adjustment for the CYCLE

pressed.

 

SOLENOID.

 

2.

Check that the SPRING is on the

 

 

DIRECTION LEVER.

 

3.

Check for a bind in the DIRECTION LEVER

 

 

ASSEMBLY.

 

4.

Check that the DIRECTION LEVER LINK is

 

 

in the correct position.

 

 

 

SLIDE TRAY does not rotate freely when the

1.

Press and release the SELECT BUTTON.

SELECT BUTTON is pressed down. The

 

• Check that the LOCATOR LEVER

projector has power.

 

 

 

moves correctly and is not bent.

 

 

 

 

2.

Press and hold the SELECT BUTTON

 

 

down.

 

 

• Check the SLIDE LIFT LEVER RAMP

 

 

 

for damage.

 

3.

Check the height of the SLIDE LIFT

 

 

LEVER; the lower corner of the LIFT

 

 

LEVER RAMP is parallel with the TOP

 

 

HOUSING. If the height is not correct, do

 

 

the adjustment for the MANUAL and

 

 

POWER SLIDE LIFT LEVER

 

 

ECCENTRICS.

 

 

 

 

SM5440-1 – 18NOV97

47

Image 47
Contents Kodak Carousel Projectors Table of Contents Adjusting the Focus Light Path Auto Focus Models Replacing the FAN Shaft Assembly Replacing the Lower Housing AssemblyInstalling the Lower Housing Assembly Replacements and Installations FAN Belt Installing the FAN Shaft AssemblyScrew Motor Installing the MotorReplacing the Motor Replacing the Worm Pulley and Mechanism Belt Worm Pulley Screw Mechanism Belt Installing the Worm Pulley and Mechanism BeltReplacing the Lamp Module Receptacle Replacing the Thermal Fuse AssemblyInstalling the Thermal Fuse Assembly Installing the Lamp Module Receptacle Pulley Shaft Replacing the Cycle Solenoid AssemblyInstalling the Cycle Solenoid Assembly Plunger AssemblyMechanism Assembly Replacing the Mechanism AssemblyInstalling the Mechanism Assembly Worm Pulley Auto Focusscrew Cyclebracket Solenoid Assembly Replacing the AUTO-FOCUS Bracket AssemblyInstalling the AUTO-FOCUS Bracket Assembly Replacing the CAM Stack Assembly and Cycle Lever AssemblyLift Lever Shaft Select Lever A0910010HCA Installing the CAM Stack Assembly and Cycle Lever Assembly Lamp Door Replacing the Lamp Socket Terminal AssemblyInstalling the Lamp Socket Terminal Assembly Installing the Lens Mount Assembly Auto Focus Models Replacing the Lens Mount Assembly Auto Focus ModelInstalling the Lens Mount Assembly Non Auto Focus Model Replacing the Lens Mount Assembly Non Auto Focus ModelReplacing the Focus Shaft Assembly Auto Focus Models Replacing the AUTO-FOCUS Switch AssemblyInstalling the AUTO-FOCUS Switch Assembly Clamp Lever Screw Lens Mount AssemblySwitch AssemblyReplacing the Focus Shaft Assembly Non Auto-Focus Models Installing the Focus Shaft AssemblyInstalling the Focus Shaft Assembly Mechanism Assembly BAR Adjustment SpecificationAdjusting the Cycle Solenoid Adjusting the Indexer Lever Assembly Slide Lift Lever Guage TL-3001 Select Adjusting the Slide Lift Lever MANUAL, with Mechanism OutAdjusting the Slide Lift Lever Power with Mechanism Out Slide Lift Lever Guage TL-3001 Select AUTO-FOCUS Target Slide TL-3002 Adjusting the NullAdjustment Tool Spring Hook TL-1165 Auto Focus Bracket AssemblyAdjusting the Photocell Photocell Mask Soldering IronClamp Lever PAD FAN CAP HousingClamp PAD AUTO-FOCUS Assembly Target SlideFAN CAP Screw NUT Clamp PAD Assembly Adjusting the Clamp PAD AssemblyAdjusting the Dark Shutter Dark Shutter Pressure PAD FAN Worm Pulley Assembly CAM Stack Assembly Cycle LeversLubrication A0910022DA Super Lube Adjustment T-BARAUTO-FOCUS Gauge AUTO-FOCUS Target SlideGrounded Power Cords SpecificationsPIN Remote Control Main Motor Voltages DiagnosticsPIN Remote Cord Plug Voltages Photocell VoltagesSmall Component Board Assembly 256809 Voltages Voltage Specifications General Parts Power, Illumination, and Cooling MalfunctionsCycle Lever Slide Transport MalfunctionsControl Super Lube TL-4276Direction Lever Lever AssemblyPower Slide Lift Lever EccentricsFocus Malfunctions Board Gate MechanismCheck that the alignment of the Target Eastman Kodak Company