Kodak 4400, 4200-KK, 5600-KK, 4600-KK, 5600-J, 4200-J Check that the alignment of the Target

Page 50

SERVICE MANUAL

Malfunction

 

Check

 

 

 

AUTO FOCUS MOTOR operates continually

1.

Install the TARGET SLIDE TL-3002 in the

 

 

GATE MECHANISM.

 

2.

Check that the alignment of the TARGET

 

 

and NULL is correct. If not, see the

 

 

Adjustments section.

 

3.

Check for a light leak:

 

 

• Install a different LAMP MODULE

 

 

ASSEMBLY. If the FOCUS MOTOR

 

 

stops operating continually, install a

 

 

new LAMP MODULE ASSEMBLY.

 

4.

Check that the voltages across the

 

 

PHOTOCELL are correct. The voltage

 

 

from 1 to 2 is 13.8 V ac. The voltage from

 

 

2 to 3 is 13.8 V ac. The voltage from 1 to 3

 

 

is 28 V ac.

 

5.

Check that the PHOTOCELL HOUSING

 

 

has 2 FILTERS.

 

6.

Install a new PHOTOCELL.

 

7.

Check the components on the CIRCUIT

 

 

BOARD for damage.

 

 

 

AUTO FOCUS MOTOR operates continually in

1.

Check that the wires of the AUTO FOCUS

forward only or reverse only and does not

 

MOTOR are in the correct position; the blue

operate (stops) in the null position.

 

wire goes to the mark on the AUTO FOCUS

 

 

MOTOR.

 

 

AUTO FOCUS adjusts after REMOTE use

1. Do the adjustment for the CLAMP LEVER

 

 

ASSEMBLY.

 

 

 

50

18NOV97 – SM5440-1

Image 50
Contents Kodak Carousel Projectors Table of Contents Adjusting the Focus Light Path Auto Focus Models Replacing the FAN Shaft Assembly Replacing the Lower Housing AssemblyInstalling the Lower Housing Assembly Replacements and Installations Installing the FAN Shaft Assembly FAN BeltScrew Motor Installing the MotorReplacing the Motor Replacing the Worm Pulley and Mechanism Belt Installing the Worm Pulley and Mechanism Belt Worm Pulley Screw Mechanism BeltReplacing the Lamp Module Receptacle Replacing the Thermal Fuse AssemblyInstalling the Thermal Fuse Assembly Installing the Lamp Module Receptacle Plunger Assembly Replacing the Cycle Solenoid AssemblyInstalling the Cycle Solenoid Assembly Pulley ShaftMechanism Assembly Replacing the Mechanism AssemblyInstalling the Mechanism Assembly Replacing the CAM Stack Assembly and Cycle Lever Assembly Replacing the AUTO-FOCUS Bracket AssemblyInstalling the AUTO-FOCUS Bracket Assembly Worm Pulley Auto Focusscrew Cyclebracket Solenoid AssemblyLift Lever Shaft Select Lever A0910010HCA Installing the CAM Stack Assembly and Cycle Lever Assembly Lamp Door Replacing the Lamp Socket Terminal AssemblyInstalling the Lamp Socket Terminal Assembly Replacing the Lens Mount Assembly Auto Focus Model Installing the Lens Mount Assembly Auto Focus ModelsReplacing the Lens Mount Assembly Non Auto Focus Model Installing the Lens Mount Assembly Non Auto Focus ModelReplacing the Focus Shaft Assembly Auto Focus Models Replacing the AUTO-FOCUS Switch AssemblyInstalling the AUTO-FOCUS Switch Assembly Assembly Lens Mount AssemblySwitch Clamp Lever ScrewInstalling the Focus Shaft Assembly Replacing the Focus Shaft Assembly Non Auto-Focus ModelsInstalling the Focus Shaft Assembly Mechanism Assembly BAR Adjustment SpecificationAdjusting the Cycle Solenoid Adjusting the Indexer Lever Assembly Slide Lift Lever Guage TL-3001 Select Adjusting the Slide Lift Lever MANUAL, with Mechanism OutAdjusting the Slide Lift Lever Power with Mechanism Out Slide Lift Lever Guage TL-3001 Select Spring Hook TL-1165 Auto Focus Bracket Assembly Adjusting the NullAdjustment Tool AUTO-FOCUS Target Slide TL-3002Adjusting the Photocell Soldering Iron Photocell MaskFAN CAP Housing Clamp Lever PADClamp PAD AUTO-FOCUS Assembly Target SlideFAN CAP Screw NUT Clamp PAD Assembly Adjusting the Clamp PAD AssemblyAdjusting the Dark Shutter Dark Shutter Pressure PAD Worm Pulley Assembly CAM Stack Assembly Cycle Levers FANLubrication A0910022DA AUTO-FOCUS Target Slide Adjustment T-BARAUTO-FOCUS Gauge Super LubeSpecifications Grounded Power CordsPIN Remote Control Diagnostics Main Motor VoltagesPhotocell Voltages PIN Remote Cord Plug VoltagesSmall Component Board Assembly 256809 Voltages Power, Illumination, and Cooling Malfunctions Voltage Specifications General PartsSuper Lube TL-4276 Slide Transport MalfunctionsControl Cycle LeverEccentrics Lever AssemblyPower Slide Lift Lever Direction LeverFocus Malfunctions Gate Mechanism BoardCheck that the alignment of the Target Eastman Kodak Company