Emerson 400501-05 installation manual Fault Codes, Display Fault Action to Reset Bridge Disabled

Page 52

Epsilon Eb Digital Servo Drive Installation Manual

Display Indication

Status

Description

Ready to Run

Drive enabled, no Stop input.

Fault Codes

A number of diagnostic and fault detection circuits are incorporated to protect the drive. Some faults, like high DC bus and amplifier or motor over temperature, can be reset with the Reset button on the front of the drive or the Reset input function. Other faults, such as encoder faults, can only be reset by cycling power “Off” (wait until the status display turns “Off”), then power “On.”

The drive accurately tracks motor position during fault conditions. For example, if there is a Low DC Bus fault where the power stage is disabled, the drive will continue to track the motor’s position provided the logic power is not interrupted.

The +/- Travel Limit faults are automatically cleared when the fault condition is removed. The table below lists all the fault codes in priority order from highest to lowest. This means that if two faults are active, only the higher priority fault will be displayed.

Display

Fault

Action to Reset

Bridge Disabled

NVM Invalid

Button or Input

Yes

Drive Overtemp

Cool down, Cycle Power

Yes

Power Module

Power

Yes

High DC Bus

Button or Input

Yes

Low DC Bus

Button or Input

Yes

34

Image 52
Contents Installation Manual Page Epsilon Eb Digital Servo Drive Installation Manual Control Techniques Drives, Inc Customer Service FAXTraining Services 952 995-8000 or 800 Document ConventionsEpsilon Only This RepresentsSafety Instructions Reference MaterialsGeneral Warning Qualified PersonSafety Precautions Setup, Commissioning and MaintenanceSafety of Machinery EnclosureViii Drive Overload Protection Underwriters Laboratories ListedRated output current Amps RMS Drive Model Continuous Peak CE Declaration of Conformity Supplementary information Xii Table of Contents Options and Accessories Diagnostics and TroubleshootingSpecifications Index Epsilon Eb Digital Servo Drive Installation Manual Xvi Drive Model Power Rating Continuous Current Peak Current FeaturesEpsilon Eb Digital Servo Drive Epsilon Eb Drives Feature Location Basic Installation Notes Electromagnetic Compatibility EMCAchieving Low Impedance Connections AC Line Filter Installation Notes AC Line FiltersEpsilon Series Schaffner Control Techniques Rating Drive RatingCable Type Cable to Enclosure ShieldingActual Hole Size Environmental Considerations AC Filter and Cable Connections for Epsilon DrivesMechanical Installation Wiring NotesDrive Mounting Motor MountingElectrical Installation Typical System Grounding DiagramPower Supply Requirements AC Supplies not Requiring TransformersAC Supplies Requiring Transformers Earth Grounded WYE Distribution TransformerDelta to Delta Isolation Transformer Transformer Sizing Drive/Motor Combination Suggested KVA RatingLine Fusing and Wire Size Inrush Current AmpsAmps RMS at St Cycle 2nd CycleInput Power Connections Epsilon AC Power Wiring DiagramAlternate Power Supply Wiring Epsilon Auxiliary Power Supply Wiring DiagramAPS Input Specification Voltage Range Current Inrush CurrentMotor Power Wiring Multiple APS Wiring DiagramMotor Feedback Wiring Motor Brake WiringEpsilon Brake Wiring Diagram using the Command Connector Input/Output and Drive Enable Wiring Epsilon Input/Output Wiring DiagramCommand Connector Wiring Epsilon I/O to Command Connector Internal ConnectionsCommand Connector J5 Pinout and CMDO-XXX Wire Colors Function Pin Numbers Electrical CharacteristicsCommand Cables Analog Command Wiring Analog Command, Differential Wiring DiagramEncoder Output Signal Wiring Command Connector Encoder Output WiringPulse Mode Wiring, Differential Inputs Pulse Mode, Differential Output to Differential InputPulse Mode Wiring, Single Ended Inputs Master/Slave Encoder Connections Serial Communications Modbus Communications Serial Communications SpecificationsMulti-Drop Communications Multi-Drop Wiring Pinout Diagnostic Display Display Indication Status DescriptionFault Codes Display Fault Action to Reset Bridge DisabledFault Descriptions Diagnostics and TroubleshootingPower Module High DC Bus Threshold Low DC Bus TresholdEncoder State Diagnostic Analog Output Test Points Output Source Offset ScaleDrive Faults Diagnostic Cable Dgne DiagramResetting Faults Viewing Active Drive FaultsRebooting the Drive Watch WindowWatch Window View Motor Parameters GroupOptions and Accessories ECI-44 External Connector Interface Dimensions of ECI-44STI-EIO Interface STI EIOECI-44 Signal Connections Drive Specifications Encoder Output Signal Fault Detection CapabilityShunt Resistor Capacity Regeneration CapacityDrive and Motor Combination Specifications Motor Brake Specifications Motor WeightsAxial/Radial Loading IP RatingsMotor Max Radial Load lb Max. Axial Load lb Encoder Specifications Power DissipationPower Dissipation Calculation Motor Density Output Type Output Signals Power SupplySpeed Torque Curves Motor Mounting Plate SizeEpsilon Speed Torque Curves, sheet 1 Epsilon Speed Torque Curves, sheet 2 Epsilon Drive Dimensions Eb 202, Eb-203, Eb-205 Following table applies to A* and B* as shown in FigureMGE-205 and 208 Mounting Dimensions inches mm MG Motor DimensionsMGE-205 and 208 Motors MGE-316, MGM-316, and MGM-340 Mounting Dimensions MGE-316, MGM-316, and MGM-340 Mounting Dimensions Inches mmMGE-316 and 340 Motors MGE-455, 490 and 4120 Mounting Dimensions inches mm MGE-455, 490 and 4120 MotorsMGE-455, 490 and 4120 Mounting Dimensions mm inches MGM-455, 490 and 4120 MotorsNT Motor Dimensions NTE-207 Motors English Face Nema 23 with 3/8 inch shaftNTM-207 Motors Metric Face NTE-212 Motors English Face Nema 23 with 3/8 inch shaft NTM-212 Motors Metric Face Cable Diagrams Drive SignalCMDX-XXX Cable CMDO-XXX Cable CDRO-XXX Cable AX-CEN-XXX Cable EIO-XXX Cable TIA-XXX CableDDS-XXX Cable TERM-H Head Terminator TERM-T Tail Terminator CMDS-XXX Cable CMMS-XXX CableCFCS-XXX Cable CFCO-XXX Cable CFOS-XXX Cable Vendor Contact Information Index STI-EIO Index Epsilon Eb Digital Servo Drive Installation Manual