Emerson Epsilon Eb Digital Servo Drive, 400501-05 installation manual MGE-455, 490 and 4120 Motors

Page 77

Specifications

MGE-455, 490 and 4120 Motors

MGE-455, 490 and 4120 Mounting Dimensions inches (mm)

 

AG

A

BC

AH

U Max

XD

S Min

 

8.61

5.00

.53

190

.6245

1.50

.1875

455

(127.0

(13.5

(48.2

(15.862

(38.1

(4.763

(218.7)

 

)

)

)

)

)

)

 

 

 

11.11

5.00

.53

190

.8750

1.50

.1875

490

(282.10

(127.0

(13.5

(48.2

(22.225

(38.1

(4.763

 

)

)

)

)

)

)

)

 

13.61

5.00

.53

190

.8750

1.50

.1875

4120

(345.70

(127.0

(13.5

(48.2

(22.225

(38.1

(4.763

 

)

)

)

)

)

)

)

 

 

 

 

 

 

 

 

MGE-455, 490 and 4120 Mounting Dimensions inches (mm)

 

R

C Max

AJ

BB

AK

BF

455

.51

3.20

5.875

.10

4.500

3/8-16

(13.0)

(81.3)

(149.23)

(2.50)

(114.30)

UNC

 

490

.77

3.20

5.875

.10

4.500

3/8-16

(19.6)

(81.3)

(149.23)

(2.50)

(114.30)

UNC

 

4120

.77

3.20

5.875

.10

4.500

3/8-16

(19.6)

(81.3)

(149.23)

(2.50)

(114.30)

UNC

 

 

 

 

 

 

 

 

59

Image 77
Contents Installation Manual Page Epsilon Eb Digital Servo Drive Installation Manual Control Techniques Drives, Inc FAX Customer ServiceDocument Conventions Training Services 952 995-8000 or 800This Represents Epsilon OnlyReference Materials Safety InstructionsGeneral Warning Qualified PersonSetup, Commissioning and Maintenance Safety PrecautionsSafety of Machinery EnclosureViii Rated output current Amps RMS Drive Model Continuous Peak Underwriters Laboratories ListedDrive Overload Protection CE Declaration of Conformity Supplementary information Xii Table of Contents Specifications Diagnostics and TroubleshootingOptions and Accessories Index Epsilon Eb Digital Servo Drive Installation Manual Xvi Epsilon Eb Digital Servo Drive FeaturesDrive Model Power Rating Continuous Current Peak Current Epsilon Eb Drives Feature Location Electromagnetic Compatibility EMC Basic Installation NotesAchieving Low Impedance Connections AC Line Filters AC Line Filter Installation NotesEpsilon Series Schaffner Control Techniques Rating Drive RatingActual Hole Size Cable to Enclosure ShieldingCable Type AC Filter and Cable Connections for Epsilon Drives Environmental ConsiderationsWiring Notes Mechanical InstallationDrive Mounting Motor MountingTypical System Grounding Diagram Electrical InstallationAC Supplies not Requiring Transformers Power Supply RequirementsEarth Grounded WYE Distribution Transformer AC Supplies Requiring TransformersDelta to Delta Isolation Transformer Drive/Motor Combination Suggested KVA Rating Transformer SizingInrush Current Amps Line Fusing and Wire SizeAmps RMS at St Cycle 2nd CycleEpsilon AC Power Wiring Diagram Input Power ConnectionsEpsilon Auxiliary Power Supply Wiring Diagram Alternate Power Supply WiringVoltage Range Current Inrush Current APS Input SpecificationMultiple APS Wiring Diagram Motor Power WiringMotor Brake Wiring Motor Feedback WiringEpsilon Brake Wiring Diagram using the Command Connector Epsilon Input/Output Wiring Diagram Input/Output and Drive Enable WiringEpsilon I/O to Command Connector Internal Connections Command Connector WiringFunction Pin Numbers Electrical Characteristics Command Connector J5 Pinout and CMDO-XXX Wire ColorsCommand Cables Analog Command, Differential Wiring Diagram Analog Command WiringCommand Connector Encoder Output Wiring Encoder Output Signal WiringPulse Mode, Differential Output to Differential Input Pulse Mode Wiring, Differential InputsPulse Mode Wiring, Single Ended Inputs Master/Slave Encoder Connections Serial Communications Multi-Drop Communications Serial Communications SpecificationsModbus Communications Multi-Drop Wiring Pinout Display Indication Status Description Diagnostic DisplayDisplay Fault Action to Reset Bridge Disabled Fault CodesDiagnostics and Troubleshooting Fault DescriptionsHigh DC Bus Threshold Low DC Bus Treshold Power ModuleEncoder State Output Source Offset Scale Diagnostic Analog Output Test PointsDiagnostic Cable Dgne Diagram Drive FaultsViewing Active Drive Faults Resetting FaultsRebooting the Drive Watch WindowWatch Window Group View Motor ParametersOptions and Accessories Dimensions of ECI-44 ECI-44 External Connector InterfaceSTI EIO STI-EIO InterfaceECI-44 Signal Connections Drive Specifications Fault Detection Capability Encoder Output SignalShunt Resistor Capacity Regeneration CapacityDrive and Motor Combination Specifications Motor Weights Motor Brake SpecificationsMotor Max Radial Load lb Max. Axial Load lb IP RatingsAxial/Radial Loading Power Dissipation Encoder SpecificationsPower Dissipation Calculation Motor Density Output Type Output Signals Power SupplyMotor Mounting Plate Size Speed Torque CurvesEpsilon Speed Torque Curves, sheet 1 Epsilon Speed Torque Curves, sheet 2 Following table applies to A* and B* as shown in Figure Epsilon Drive Dimensions Eb 202, Eb-203, Eb-205MGE-205 and 208 Motors MG Motor DimensionsMGE-205 and 208 Mounting Dimensions inches mm MGE-316 and 340 Motors MGE-316, MGM-316, and MGM-340 Mounting Dimensions Inches mmMGE-316, MGM-316, and MGM-340 Mounting Dimensions MGE-455, 490 and 4120 Motors MGE-455, 490 and 4120 Mounting Dimensions inches mmMGM-455, 490 and 4120 Motors MGE-455, 490 and 4120 Mounting Dimensions mm inchesNTE-207 Motors English Face Nema 23 with 3/8 inch shaft NT Motor DimensionsNTM-207 Motors Metric Face NTE-212 Motors English Face Nema 23 with 3/8 inch shaft NTM-212 Motors Metric Face Drive Signal Cable DiagramsCMDX-XXX Cable CMDO-XXX Cable CDRO-XXX Cable AX-CEN-XXX Cable TIA-XXX Cable EIO-XXX CableDDS-XXX Cable TERM-H Head Terminator CMDS-XXX Cable CMMS-XXX Cable TERM-T Tail TerminatorCFCS-XXX Cable CFCO-XXX Cable CFOS-XXX Cable Vendor Contact Information Index STI-EIO Index Epsilon Eb Digital Servo Drive Installation Manual