When the
•Pr 6.42 to 0
•Pr 6.43 to On
•Pr 3.22 to 0 (where present)
•Pr 3.23 to On (where present)
•Pr 3.13 to Off (In
•Pr 2.10 to 1
•Pr 2.20 to 1
•Pr 2.02 to On
•Pr 1.04 to 0
•Pr 1.21 to 0
•Pr 1.38 to 0
•Pr 1.08 to Off
•Pr 1.10 to On
•Pr 1.09 to Off
•Pr 1.15 to 1
•Pr 1.14 to 3
These values are set once and not continuously forced. They are not reset when leaving the Operational state. In addition, the option starts to write parameters implicitly mapped by the CoE profiles, when moving to the Operational state.
7.3.20x605A Quick stop option code
This object indicates what action is perfomed when the quick stop function is executed. The slow down ramp is the deceleration value of the used mode of operations.
Table 7.9 Quick_stop_option_code
0x605A | Quick_stop_option_code |
|
| |
Access: RW |
| Range: 0 to 6 | Size: Unsigned 16 | Unit: N/A |
|
|
|
|
|
Default: | 2 |
|
|
|
|
| |||
Description: | Specifies what action is performed in the event of a quick stop function. See Table 7.8 CoE | |||
| state machine transition and events for more information. |
| ||
|
|
|
|
|
Table 7.10 Quick stop value definitions
Value | Definition |
0 | Disable drive function |
|
|
1 | Slow down on slow down ramp and transit into Switch on disabled |
2 | Slow down on quick stop ramp and transit into Switch on disabled |
|
|
5 | Slow down on slow down ramp and stay in Quick stop active |
|
|
6 | Slow down on quick stop ramp and stay in Quick stop active |
Information | Safety |
| |
Introduction | |
|
|
Installation | Mechanical |
|
|
Installation | Electrical |
| |
Getting Started | |
| |
Protocols | |
|
|
support | Drive profile |
features | Advanced |
| |
Diagnostics | |
|
|
Reference | Quick |
|
|
Terms | Glossary |
| Of |
| |
Index | |
|
|
33 | |
Issue Number: 2 | www.controltechniques.com |