SATO CX200 manual Pcba Module Removal/Replacement, Module removal, Module replacement

Page 44

3-7 PCBA Module Removal/Replacement

REFER TO THE ACCOMPANYING ILLUSTRATIONS

Module removal:

1.Remove the printer chassis according to the instructions in Section 3-4.

2.Remove the module from the PCBA base board by pressing outward on the two spring clips at the left and right ends of the module .

3.Lift the module up and out to remove.

PRESS THE TWO

SPRING CLIPS

OUTWARD

PRESS THE TWO

SPRING CLIPSPCBA MODULE

OUTWARD

PCBA BASE

BOARD

Module replacement:

1.Press the module firmly into its connector on the PCBA base board.

2.Press the top edge of the module in toward the printer body until the connector spring clips engage.

3.Reinstall the chassis in the case according to the directions in Section 3-4.

43

SATO SERVICE MANUAL

CX Series Printers

Rev B

Image 44
Contents CX200 Section OverviewDimensions Specifications EnvironmentalAttributes Attributes Controls, Indicators and Connections Device Name Primary Function USESerial Input Connector DB9S Printer Power Connection Connecting the Interface Cable Printer Setup Loading Labels or Tags Also Refer to the Accompanying Illustrations NextPrinter Setup Loading Labels or Tags Printer Setup Loading Ribbon Also Refer to the Accompanying IllustrationsPrinter Setup Loading Ribbon Printer Setup Loading Ribbon Selecting the Label Sensor Type Installing the software to your hard drive Printer Test and Calibration Preparation for TestRunning the software from your 3-1/2 drive Description of Test MenuAccess the software Printer Test and Calibration Print Head / Status PrintPrinter Test and Calibration Change RS232 Settings Printer Test and Calibration Change RS232 Settings Printer Test and Calibration Set Top of Form Pitch Offset Printer Test and Calibration Set Top of Form Pitch Offset Printer Test and Calibration Calibrate Printer Sequence of events when the Calibration Program is run Basic Operations Printing and Reading a Self-test Label Example Self Test Label Printer Ready/Standby/Reset Control Basic Operations Feeding Blank LabelsLabel Reprint Sending Data to the PrinterPrinting Labels Basic Operations Printer Ready/Standby/Reset ControlControlling the Printer Using Direct Commands Maintenance CleaningCleaning Clean Platen Rollerlabel Feed Direction Rev Parts Replacement Preparing the Printer for ServiceReplaceable Parts Section Description KIT Part NumberReplaceable Parts Replaceable Parts Location Top Case Removal/Replacement Refer to the IllustrationChassis, Including the Front Case Removal/Replacement To remove the chassisChassis, Including Front Case Removal/Replacement To replace the chassis and front casePlaten removal Platen Removal/ReplacementPlaten installation Print Head Removal/Replacement Print head removalPrint head installation Module removal Pcba Module Removal/ReplacementModule replacement PCA board removal PCA Base Board Removal/ReplacementPCA board installation Motor removal Motor Removal/ReplacementMotor installation Switch installation Head Open Switch Removal/ReplacementSwitch removal Cluster gear removal Cluster Gear Removal/ReplacementCluster gear installation CX Series Printers Troubleshooting Preliminary TestsCommon Problems and Their Solutions Ready light is not litHost stops responding or displays printer not ready message Printer feeds too many labels Ribbon wrinkles Printed labels are cut off at the bottom
Related manuals