Xantrex Technology PH1800 manual Selecting Charger Settings, Ac Led

Page 29

 

Inverter Control Panel

 

 

Solar LED

When the Select Button is pressed again within 10 seconds and the Solar

 

LED is illuminated, the Solar Input wattage levels are displayed in

 

kilowatts. These values are the inputs on the 32 A DC input terminals.

AC LED

If the unit is in Bypass Mode, when the Select Button is pressed again

 

within 10 seconds and the AC LED is illuminated, the battery charger

 

power level is displayed in kilowatts.

Output LEDs

Net Power LED

By default the Net Power LED represents the difference between the

 

input and the output power levels. This value is shown on startup and will

 

return to this display if the Select button is not pressed for 10 seconds.

 

When using the Select Button to cycle through the displays and the Net

 

Power LED is illuminated, the power level displayed will depend on

 

whether the unit is in Bypass Mode or Inverter Mode.

 

In Bypass Mode, the value displayed represents the power, in kilowatts,

 

that is available to charge the battery and to power the loads. This will be

 

a positive number.

 

In Inverter Mode, this value displayed represents the total amount of

 

power in kilowatts that is being drawn from the battery bank (negative

 

numbers) or is available to charge the battery by the DC source while the

 

inverter is running (positive numbers).

Battery LED

When the Select Button is pressed again within 10 seconds and the

 

Battery Level LED is illuminated, the battery voltage level is displayed in

 

DC volts. It will also show “FUL” when the battery is charged through the

 

AC charger and reaches float and standby mode.

Output LED

When the Select Button is pressed again within 10 seconds and the

 

Inverter LED is illuminated, the Inverter Output power is displayed in

 

kilowatts. This only displays if the unit is in Invert Mode.

Selecting Charger Settings

Charger

Pressing and holding the Select Button for 3-5 seconds will change the

Settings

display to show the AC charger current setting and the AC LED will

 

flash.

 

See “Battery Charger Features” on page 1–5 for more information

 

regarding setting parameters. See “Changing Charging Settings” on

 

page 2–9 for instructions on changing this setting.

975-0288-01-01

2–5

Image 29
Contents PowerHub Page Operator’s Guide PowerHubDate and Revision Purpose About This GuideScope AudienceRelated Information Conventions UsedAbbreviations and Acronyms Important Safety Instructions Figure i Basic Safety Precautions When Working With Batteries FCC/ICES 003 Information to the User Precautions for Using Rechargeable AppliancesTo Power Down the PowerHub Power Down ProcedureIf hardwired...... To Power Down the PowerHub Contents Specifications TroubleshootingFigures Xiv Tables Page For this topic See IntroductionPrinciples of Inverter Operation IntroductionPrimary AC source Basic Functions of the PowerHub2PowerHub 1800 Features Inverter FeaturesThree-Stage Charging Process on Battery Charger FeaturesVoltage 12.5 Vdc Operation Contains information on operating the PowerHubInverter Control Panel 8.8LED User Controls and DisplayStatus LEDs Operating Mode LEDsAC LED Selecting Charger SettingsBasic Operation Power On and Off3Input Displays Changing the Display4Output Displays AC is not available Changing Charging SettingsConnecting AC Loads 6Connecting AC Loads Loads that should not be used with the PowerHub Typical Loads that might be used with the PowerHubLoads That Might Not Work Well With the PowerHub Troubleshooting How to Troubleshoot the PowerHub Error Codes Troubleshooting Error Codes for Troubleshooting the PowerHub 2Possible Problems if Utility Power is Not Available If Utility Power is not AvailableError code E02 3Possible Problems if Utility Power is Available If Utility Power is AvailablePossible Problem Loads Rechargeable Devices Replacing the Ground Fault Protection Fuse Ground Fault Protection1Replacing Ground Fault Protection Fuse Page Specifications Table A-1Electrical Specifications for the Inverter Electrical SpecificationsBattery Charger Specifications Physical SpecificationsFigure A-1Three-Stage Charging Process Amp Charging Profile Charging ProfilesTable A-610-amp Charging Profile Index IX-2 975-0288-01-01 Warranty Warranty and Return InformationProduct DisclaimerExclusions Return Material Authorization PolicyReturn Procedure Out of Warranty Service Purchased From Purchase Date Information About Your SystemWA-6 Page Xantrex Technology Inc