Xantrex Technology PH1800 manual Charging Profiles, Amp Charging Profile

Page 53

Battery Charger Specifications

Charging Profiles

40-amp Charging Profile

Table A-5 provides the specific charging parameters for the 40 Charging Profile.

Table A-540-amp Charging Profile

Parameter Name

Default Value

 

 

Charger Setting

40 A

Maximum Bypass Current

500 W (4 A)

Bulk Mode

40 A

Absorption Mode

14.2 Vdc (4 hours maximum)

Float Mode

13.7 Vdc (8 hours)

Switches from Absorption to Float

4 A

Mode

 

Switches from Float Mode back to

6 A

Bulk Mode within the 8-hour limit,

 

if the Float current increases to

 

6 A.

 

Standby Mode (Off Mode)

12.5 Vdc

Estimated charging time

8 hours based on a single battery box with

 

two 100 Ah, 12 Vdc batteries and no

 

other DC charging sources

 

 

975-0288-01-01

A–5

Image 53
Contents PowerHub Page Operator’s Guide PowerHubDate and Revision Purpose About This GuideScope AudienceRelated Information Conventions UsedAbbreviations and Acronyms Important Safety Instructions Figure i Basic Safety Precautions When Working With Batteries FCC/ICES 003 Information to the User Precautions for Using Rechargeable AppliancesTo Power Down the PowerHub Power Down ProcedureIf hardwired...... To Power Down the PowerHub Contents Specifications TroubleshootingFigures Xiv Tables Page For this topic See IntroductionPrinciples of Inverter Operation IntroductionPrimary AC source Basic Functions of the PowerHub2PowerHub 1800 Features Inverter FeaturesThree-Stage Charging Process on Battery Charger FeaturesVoltage 12.5 Vdc Operation Contains information on operating the PowerHubInverter Control Panel 8.8LED User Controls and DisplayStatus LEDs Operating Mode LEDsAC LED Selecting Charger SettingsBasic Operation Power On and Off3Input Displays Changing the Display4Output Displays AC is not available Changing Charging SettingsConnecting AC Loads 6Connecting AC Loads Loads that should not be used with the PowerHub Typical Loads that might be used with the PowerHubLoads That Might Not Work Well With the PowerHub Troubleshooting How to Troubleshoot the PowerHub Error Codes Troubleshooting Error Codes for Troubleshooting the PowerHub 2Possible Problems if Utility Power is Not Available If Utility Power is not AvailableError code E02 3Possible Problems if Utility Power is Available If Utility Power is AvailablePossible Problem Loads Rechargeable Devices Replacing the Ground Fault Protection Fuse Ground Fault Protection1Replacing Ground Fault Protection Fuse Page Specifications Table A-1Electrical Specifications for the Inverter Electrical SpecificationsBattery Charger Specifications Physical SpecificationsFigure A-1Three-Stage Charging Process Amp Charging Profile Charging ProfilesTable A-610-amp Charging Profile Index IX-2 975-0288-01-01 Warranty Warranty and Return InformationProduct DisclaimerExclusions Return Material Authorization PolicyReturn Procedure Out of Warranty Service Purchased From Purchase Date Information About Your SystemWA-6 Page Xantrex Technology Inc