Xantrex Technology PH1800 manual Table A-610-amp Charging Profile

Page 54

Specifications

10-amp Charging Profile

Table A-6 provides the specific charging parameters for the 10 Charging Profile.

Table A-610-amp Charging Profile

Parameter Name

Default Value

 

 

Charger Setting

10 A

Maximum Bypass Current

1200 W (10 A)

Bulk Mode

10 A

Absorption Mode

14.2 Vdc (4 hours maximum)

Float Mode

13.7 Vdc (8 hours)

Switches from Absorption to

4 A

Float Mode

 

Switches from Float Mode

6 A

back to Bulk Mode within the

 

8-hour limit, if the Float

 

current increases to 6 A.

 

Standby Mode (Off Mode)

12.5 Vdc

Estimated charging time

32 hours based on a single battery box with

 

two 100 Ah, 12 Vdc batteries and no other DC

 

charging sources

 

 

0-amp Charging Profile

When Charger Setting 0 A is selected, the Battery Charger is disabled and will not charge the batteries. Use this mode if other DC charging sources are available or if it is necessary to temporarily disconnect the AC charging system.

A–6

975-0288-01-01

Image 54
Contents PowerHub Page PowerHub Operator’s GuideDate and Revision Scope About This GuidePurpose AudienceConventions Used Abbreviations and AcronymsRelated Information Important Safety Instructions Figure i Basic Safety Precautions When Working With Batteries Precautions for Using Rechargeable Appliances FCC/ICES 003 Information to the UserPower Down Procedure To Power Down the PowerHubIf hardwired...... To Power Down the PowerHub Contents Troubleshooting SpecificationsFigures Xiv Tables Page Introduction For this topic SeeIntroduction Principles of Inverter OperationBasic Functions of the PowerHub Primary AC sourceInverter Features 2PowerHub 1800 FeaturesBattery Charger Features Three-Stage Charging Process onVoltage 12.5 Vdc Contains information on operating the PowerHub Operation8.8 Inverter Control PanelUser Controls and Display LEDOperating Mode LEDs Status LEDsSelecting Charger Settings AC LEDPower On and Off Basic OperationChanging the Display 3Input Displays4Output Displays Changing Charging Settings AC is not availableConnecting AC Loads 6Connecting AC Loads Typical Loads that might be used with the PowerHub Loads That Might Not Work Well With the PowerHubLoads that should not be used with the PowerHub Troubleshooting How to Troubleshoot the PowerHub Error Codes Troubleshooting Error Codes for Troubleshooting the PowerHub If Utility Power is not Available 2Possible Problems if Utility Power is Not AvailableError code E02 If Utility Power is Available 3Possible Problems if Utility Power is AvailablePossible Problem Loads Rechargeable Devices Ground Fault Protection Replacing the Ground Fault Protection Fuse1Replacing Ground Fault Protection Fuse Page Specifications Electrical Specifications Table A-1Electrical Specifications for the InverterPhysical Specifications Battery Charger SpecificationsFigure A-1Three-Stage Charging Process Charging Profiles Amp Charging ProfileTable A-610-amp Charging Profile Index IX-2 975-0288-01-01 Warranty and Return Information WarrantyDisclaimer ProductReturn Material Authorization Policy Return ProcedureExclusions Out of Warranty Service Information About Your System Purchased From Purchase DateWA-6 Page Xantrex Technology Inc