Operation

Basic Operation

The following figures show what the Inverter Control Panel will look like when the user controls are used.

Important: The values shown in the displays of the following illustrations are examples only. Actual values may vary based on what is connected to the unit.

Power On and Off

To turn the power to the

PowerHub ON or OFF:

Press and hold the green ON/OFF Power Button for approximately 1 second.

If any input power is available, the Inverter Control panel will display as shown below. The value shown on the display defaults to indicate Net Power.

Net Power = Input - Output

If no input power is available and no loads are connected to the unit, the Inverter Control panel will display as shown below.

Default Screen Example

Default Screen Example

Example indicates 540 watts.

 

Figure 2-2Basic Startup Screens

2–6

975-0288-01-01

Image 30
Contents PowerHub Page PowerHub Operator’s GuideDate and Revision Scope About This GuidePurpose AudienceConventions Used Abbreviations and AcronymsRelated Information Important Safety Instructions Figure i Basic Safety Precautions When Working With Batteries Precautions for Using Rechargeable Appliances FCC/ICES 003 Information to the UserPower Down Procedure To Power Down the PowerHubIf hardwired...... To Power Down the PowerHub Contents Troubleshooting SpecificationsFigures Xiv Tables Page Introduction For this topic SeeIntroduction Principles of Inverter OperationBasic Functions of the PowerHub Primary AC sourceInverter Features 2PowerHub 1800 FeaturesBattery Charger Features Three-Stage Charging Process onVoltage 12.5 Vdc Contains information on operating the PowerHub Operation8.8 Inverter Control PanelUser Controls and Display LEDOperating Mode LEDs Status LEDsSelecting Charger Settings AC LEDPower On and Off Basic OperationChanging the Display 3Input Displays4Output Displays Changing Charging Settings AC is not availableConnecting AC Loads 6Connecting AC Loads Typical Loads that might be used with the PowerHub Loads That Might Not Work Well With the PowerHubLoads that should not be used with the PowerHub Troubleshooting How to Troubleshoot the PowerHub Error Codes Troubleshooting Error Codes for Troubleshooting the PowerHub If Utility Power is not Available 2Possible Problems if Utility Power is Not AvailableError code E02 If Utility Power is Available 3Possible Problems if Utility Power is AvailablePossible Problem Loads Rechargeable Devices Ground Fault Protection Replacing the Ground Fault Protection Fuse1Replacing Ground Fault Protection Fuse Page Specifications Electrical Specifications Table A-1Electrical Specifications for the InverterPhysical Specifications Battery Charger SpecificationsFigure A-1Three-Stage Charging Process Charging Profiles Amp Charging ProfileTable A-610-amp Charging Profile Index IX-2 975-0288-01-01 Warranty and Return Information WarrantyDisclaimer ProductReturn Material Authorization Policy Return ProcedureExclusions Out of Warranty Service Information About Your System Purchased From Purchase DateWA-6 Page Xantrex Technology Inc