Categories
Warnings
Commands
and Queries
Read-Back Queries
Trigger and
Sync
Commands
and Queries
|
| Commands and Queries Reference | |
IHIGH | program the upper window warning level for the output current of the | ||
|
| Power Module. | |
IHIGH? | return the current settings for the upper window warning level of the | ||
|
| output current of the Power Module. | |
ILOW | program the lower window warning level for the output current of the | ||
|
| Power Module. | |
ILOW? | return the current settings for the lower window warning level of the | ||
|
| output current of the Power Module | |
VHIGH | program the upper window warning level for the load voltage of the | ||
|
| Power Module. | |
VHIGH? | return the current settings for the upper window warning level of the load | ||
|
| voltage of the Power Module. | |
VLOW | program the lower window warning level for the load voltage of the | ||
|
| Power Module. | |
VLOW? | return the current settings for the lower window warning level of the load | ||
|
| voltage of the Power Module | |
WHIGH | enable / disable window upper limits checks by the Power Module. | ||
WHIGH? | return the state of the Power Module’s upper window check enable flag. | ||
WLOW | enable / disable window lower limits checks by the Power Module. | ||
WLOW? | return the state of the Power Module’s lower window check enable flag. | ||
IALL? | return output current measurements of all operative Power Modules | ||
ILOAD? | return output current measurement of the Power Module. | ||
IOUT? | return output current measurement of the Power Module. | ||
POWER? | return the XMP 2600 delivered output power. | ||
VALL? | return load voltage measurements of all operative Power Modules. | ||
VLOAD? | return load voltage measurement of the Power Module. | ||
VOUT? | return output voltage measurement of the Power Module. | ||
|
|
|
|
|
| For their internal use (fault and warning detection), the Power Modules |
|
|
| generate a new |
|
|
| The Main Controller is updated with new values (available for readback, |
|
|
| 10 times a second. |
|
|
|
|
|
*TRG | toggles the state of the Global Output Enable Flag | ||
ARM | program a Power Module to the Armed state in which further SET and | ||
|
| PROT programming will be stored with no immediate effect of the output | |
|
| of the Power Module. | |
ARM? | return the state of the Power Module. | ||
SYNC | program the Power Module’s Sync Pulse Generation Enable Event. | ||
SYNC? | return the current Sync Pulse Generation Event for the Power Module. | ||
TRIG | program the Power Module’s reaction to a software or hardware trigger. | ||
TRIG? | return the current reaction to trigger for the Power Module. | ||
TRIGER | send a global trigger (to all Power Modules). | ||
TRIGER | send a trigger to the Power Module. |
38 | XMP 2600 Programming Manual rev. 1.1 |