Xantrex Technology XMP 2600 manual Regulatory Approvals and Safety Agency Compliance

Page 8

Power Supply Safety

WARNING

Do not operate the unit with a missing module. Modules must be arranged consecutively from left to right. Unused module locations must be closed with ventilation obstructions. Operating the unit with missing modules or missing internal ventilation obstructions may cause overheating and fire hazard.

WARNING — High Energy and High Voltage

Exercise caution when using and calibrating a power supply. High energy levels can be stored at the output voltage terminals on a power supply in normal operation. In addition, potentially lethal voltages exist in the power circuit and on the output and sense connectors of a power supply with a rated output greater than 40 V. Filter capacitors store potentially dangerous energy for some time after power is removed.

CAUTION

Operate the power supply in an environment free of flammable gases or fumes. To ensure that the power supply’s safety features are not compromised, use the power supply as specified in this manual and do not substitute parts or make any unauthorized modifications. Contact the service technician for service and repair help. Repairs must be made by experienced service technicians only

Regulatory Approvals and Safety Agency Compliance

Regulatory Approvals

European Standards:

Electromagnetic Emissions and Immunity -meets Council

 

Directive 89/336/EEC

Electromagnetic Emissions:

EN61326:1997 +A1:1998

 

EN61000-3-2:2000

 

EN61000-3-3:1995

Electromagnetic Immunity:

EC61326:1997 +A1:1998

Safety

Agency

Compliance

European Standards:

Safety

Meets EN61010 –1

 

 

American Standards:

 

Electromagnetic Emissions

Meets FCC Class A

Safety

Meets UL61010-1

XMP 2600 Programming Manual rev. 1.1

g

Image 8
Contents Xantrex Multiple Output Power System XMP XMP Limited What does this warranty cover and how long does it How do you get service?Warranty Last?What does this warranty not cover? Disclaimer ProductInformation About Your Power Supply InformationPower Supply Grounding Safety SummaryDescription Power Supply Symbols Input Mains Voltage Rating Output VoltagesDo Not Open The Unit Air Inlets And Air Outlet Nonoperative ModulesRegulatory Approvals and Safety Agency Compliance Safety Agency CompliancePower Supply Safety Regulatory ApprovalsWho should use this manual About this manualChapters Terminology Table of contents Basic Programming Commands and Queries Reference Error Codes summary Byte1Interfacing XMP Gpib interfaceSerial interface ACKProgramming messages formats Listening FormatsTalking Formats Response Data SeparatorHow to communicate with the XMP Using the comm. channelsUsing the Gpib bus Using an RS232 linkRecovering from communication halts Using queriesUsing commands Programming the XMPRecommendations on using the XMP Initialize the XMPEnforce power-on conditions Setup the XMP 2600 status systemQuery installed Power Modules Identify the XMPSetup system level protection shutdown features Initial setup of the Power ModulesProtection setup Output settingsActivation Status reportingUsing advanced features Handling SRQ and the IEEE488.2 Status StructuresOn-going usage of the XMP Use queriesEvent enable registers Status registersEvent registers Mask registersMain status byte Main controller eventsOutput message Queue Responding to SRQ eventsSummary of power modules status Power modules status structureRemote communication time out Primary engine status structureWhat happens when power is turned on Error CodeFaults Register Events RegisterUsage Guidelines Basic setup and usage Output SetupPower Module output rating Overview of output setup parametersOutput settings Output controlOutput activation Globally enabling the outputsVoltage / current mode Current limiting schemesFoldback Polarity and disconnect relaysReprogramming Delay RetryShutdown on current limit Linear foldbackBasic Programming Setting the window thresholds Workpoint window warningUsage guidelines Enabling the window thresholdsUsing the events mechanism Using the warningsVoltage mode example Checking the statusProtection using the workpoint window Load protectionAdditional usages OVPArm, trigger, sync and ramp Trigger mechanismSet output to stored values Toggle the output state on/offSync output What is output ramping? Output rampingOutput ramping setup Synchronization of operationsOutput ramping initiation Simultaneous operationsUsing hardware Trig and Sync to serialize operations Output on/offOther operations Sequential OperationsUsing software OPC mechanism to serialize operations Controller notification of Operation CompleteCommands to program shutdown grouping Selective shutdownShutdown grouping single, group, global Different shutdown grouping of modulesComm. time out Shutdown on non-fault eventsResponding to communication time out events Turn-on and reset behavior Time out events as reflected in the status structureCategories Ieee 488.1 BUS CommandsSystem Commands Queries Reset GlblGLBL? GpibSettings Commands Queries Output Control Protection Read-Back Queries Commands QueriesTrigger Sync Commands Queries Status Reporting Commands Queries Synch Alphabetical reference MnemonicParameters None Category System Type Sequential PRE Stores settings of all the Power Modules same as STO command Result register Syntax Return two decimal numbers, in the range 0 to 255. Each bit Cmask Close relay and a value of 1 is returned for an open relay Remove a user message from the XMP 2600 front panel display Set-up the operating mode of the XMP 2600. Re-calculate rqs Response is a series of values one for each installed Power Return output Current measurement of the Power Module. Return the state of the XMP 2600 Local Lock Flag. a value Ocrst Decimal value in the range 0 to Syntax Presence of the Polarity Reversal Relay Option Parameters None Category Settings Type Sequential Master mainframe. For the XMP 2600 this value is String in the following format mssnnn where m=minutes Result is two decimal numbers the first being the level 0t o SN? = Stop = Goto= OFF Module. Result is a decimal number in the range 0 to Shut-down when a remote communication time out occurs. Time out feature Syntax Minus sigh Syntax VLIM? Vset Commands and Queries Reference Ieee 488.2 compatible Status Structures Events RegisterFaults Register Error CodeEvents Enable Register Output RegisterEvents Filtering Positive Mask Register Events Filtering Negative Mask RegisterStandard Event Status Register read with *ESR? PON CME EXE DDE QYE OPCPrimary Status Register read with PSR? Primary Event Status Register read with PER?Status Byte Register read with *STB? PrimerrPower Modules Self Test ResultsByte Main ControllerError Codes summary Power Modules Errors Reported by the Power ModuleErrors Detected by the Main Controller Main Power Modules Communications errorsParser and Execution errors RS232 Communications errorsGpib Communications errors Status reporting Xantrex Technology Inc