Alphabetical reference |
| Commands and Queries Reference | |
SHUT | defines the optional events that will cause a single, group or global | ||
| shutdown. |
|
|
| Syntax | SHUT <int> |
|
| Parameters | the integer is a value in the range 0 to 7, derived | |
|
| from summing the following event category | |
|
| selections: |
|
|
| 1 – errors reported by | the Power Module (not |
|
| including error codes 7 and 8). | |
|
| 2 – sense warning. |
|
|
| 4 – window warning. |
|
| Category | System | Type: Sequential |
SHUT? | returns the | current selection of | |
| single, group or global shutdown. The returned value (in the range 0 to |
7)is a sum of individual events categories selections (see SHUT command above).
Syntax | SHUT? |
|
Parameters | none |
|
Category | System | Type: Sequential |
When the Power Supply is turned on or a full reset is performed, the selection of
SN? | return the Power Module’s Serial Number. The result is a six digit | ||
| number. |
|
|
| Syntax | SN? <ch> |
|
| Parameters | the number of the channel to be queried. | |
| Category | System | Type: Sequential |
SRQS? | return the | Power Modules Summary Register. The result is two | |
| decimal numbers. Each bit of the reply represents a channel. A bit | ||
| value of “0” means that the Power Module has no enabled status | ||
| events. A bit value of “1” means that it has. The reply is a | ||
| with its high order byte sent first. The summary bits are cleared and | ||
| <rqs> |
| |
| Syntax | SRQS? |
|
| Parameters | none |
|
| Category | Status | Type: Sequential |
60 | XMP 2600 Programming Manual rev. 1.1 |