Xantrex Technology XMP 2600 manual Result register Syntax

Page 57

Alphabetical reference

 

Commands and Queries Reference

*TST?

initiates a self-test of the XMP 2600 main control circuits. The tested

 

areas are: Controller Internal RAM, Tables Storage RAM, Settings

 

Storage Areas and Buffers RAM. The result of the self-test is reported

 

as a decimal number in the range 0 to 16 representing the bits of the

 

result register.

 

 

 

Syntax

*TST?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

*WAI

prevent the XMP 2600 from parsing any further commands or queries

 

until all pending operations have finished.

 

 

Syntax

*WAI

 

 

Parameters

none

 

 

Category

Synchronization

Type: Sequential

ARM

program a Power Module to the Armed state in which further SET,

 

PROT and POL programming will be stored with no immediate effect

 

of the output of the Power Module.

 

 

Syntax

ARM <ch>

 

 

Parameters

the number of the channel to be armed.

 

Category

Trigger and Sync

Type: Sequential

ARM?

return the state of the Power Module. The value returned is “0” if the

 

module is not armed and “1” if it is.

 

 

Syntax

ARM? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Trigger and Sync

Type: Sequential

BUFCLR

empty the Output Queue.

 

 

Syntax

BUFCLR

 

 

Parameters

none

 

 

Category

System

Type: Sequential

CALDT?

return the Calibration Date of a Power Module. The response is an

 

unquoted string with the following format: dd/mm/yy where: dd is the

 

day of the month, mm is the month and yy is the last two digits of the

 

year.

 

 

 

Syntax

CALDT? <ch>

 

 

Parameters

the number of the Channel to be queried.

 

Category

Status

Type: Sequential

44

XMP 2600 Programming Manual rev. 1.1

Image 57
Contents Xantrex Multiple Output Power System XMP XMP How do you get service? Limited What does this warranty cover and how long does itWarranty Last?Disclaimer Product What does this warranty not cover?Information Information About Your Power SupplySafety Summary Description Power Supply SymbolsPower Supply Grounding Output Voltages Input Mains Voltage RatingDo Not Open The Unit Air Inlets And Air Outlet Nonoperative ModulesSafety Agency Compliance Regulatory Approvals and Safety Agency CompliancePower Supply Safety Regulatory ApprovalsAbout this manual Chapters TerminologyWho should use this manual Table of contents Basic Programming Commands and Queries Reference Byte Error Codes summaryGpib interface 1Interfacing XMPACK Serial interfaceListening Formats Programming messages formatsResponse Data Separator Talking FormatsUsing the comm. channels How to communicate with the XMPUsing the Gpib bus Using an RS232 linkUsing queries Recovering from communication haltsUsing commands Programming the XMPInitialize the XMP Recommendations on using the XMPSetup the XMP 2600 status system Enforce power-on conditionsQuery installed Power Modules Identify the XMPInitial setup of the Power Modules Setup system level protection shutdown featuresOutput settings Protection setupActivation Status reportingHandling SRQ and the IEEE488.2 Status Structures Using advanced featuresOn-going usage of the XMP Use queriesStatus registers Event enable registersEvent registers Mask registersMain controller events Main status byteOutput message Queue Responding to SRQ eventsPower modules status structure Summary of power modules statusRemote communication time out Primary engine status structureError Code What happens when power is turned onFaults Register Events RegisterUsage Guidelines Output Setup Basic setup and usageOverview of output setup parameters Power Module output ratingOutput control Output settingsOutput activation Globally enabling the outputsCurrent limiting schemes Voltage / current modeFoldback Polarity and disconnect relaysRetry Reprogramming DelayShutdown on current limit Linear foldbackBasic Programming Workpoint window warning Setting the window thresholdsUsage guidelines Enabling the window thresholdsUsing the warnings Using the events mechanismVoltage mode example Checking the statusLoad protection Protection using the workpoint windowAdditional usages OVPTrigger mechanism Arm, trigger, sync and rampSet output to stored values Toggle the output state on/offSync output Output ramping What is output ramping?Synchronization of operations Output ramping setupOutput ramping initiation Simultaneous operationsOutput on/off Using hardware Trig and Sync to serialize operationsOther operations Sequential OperationsController notification of Operation Complete Using software OPC mechanism to serialize operationsSelective shutdown Commands to program shutdown groupingShutdown grouping single, group, global Different shutdown grouping of modulesShutdown on non-fault events Responding to communication time out eventsComm. time out Time out events as reflected in the status structure Turn-on and reset behaviorIeee 488.1 BUS Commands System Commands QueriesCategories Glbl ResetGLBL? GpibSettings Commands Queries Output Control Protection Commands Queries Trigger Sync Commands QueriesRead-Back Queries Status Reporting Commands Queries Synch Mnemonic Alphabetical referenceParameters None Category System Type Sequential PRE Stores settings of all the Power Modules same as STO command Result register Syntax Return two decimal numbers, in the range 0 to 255. Each bit Cmask Close relay and a value of 1 is returned for an open relay Remove a user message from the XMP 2600 front panel display Set-up the operating mode of the XMP 2600. Re-calculate rqs Response is a series of values one for each installed Power Return output Current measurement of the Power Module. Return the state of the XMP 2600 Local Lock Flag. a value Ocrst Decimal value in the range 0 to Syntax Presence of the Polarity Reversal Relay Option Parameters None Category Settings Type Sequential Master mainframe. For the XMP 2600 this value is String in the following format mssnnn where m=minutes Result is two decimal numbers the first being the level 0t o SN? = Goto = OFF= Stop Module. Result is a decimal number in the range 0 to Shut-down when a remote communication time out occurs. Time out feature Syntax Minus sigh Syntax VLIM? Vset Commands and Queries Reference Events Register Ieee 488.2 compatible Status StructuresError Code Faults RegisterEvents Enable Register Output RegisterEvents Filtering Negative Mask Register Events Filtering Positive Mask RegisterPON CME EXE DDE QYE OPC Standard Event Status Register read with *ESR?Primary Event Status Register read with PER? Primary Status Register read with PSR?Primerr Status Byte Register read with *STB?Self Test Results Power ModulesMain Controller BytePower Modules Errors Reported by the Power Module Error Codes summaryErrors Detected by the Main Controller Main Power Modules Communications errorsRS232 Communications errors Gpib Communications errorsParser and Execution errors Status reporting Xantrex Technology Inc