Xantrex Technology XMP 2600 manual Byte, Main Controller

Page 89

Self Test Results

Status reporting

Main Controller

BYTE 1

ANLG

DAC

ANLG

PWR

 

NOVR

NOVR

PROG

INT

MUX

 

 

REF

SUPPL

 

AM_B

AM_A

MEM

RAM

INT_RAM

Processor Memory.

 

 

 

 

PROG_MEM ..

Program Memory.

 

 

 

 

NOVRAM_A.. Non-Volatile Memory A.

 

 

 

 

NOVRAM_B ..

Non-Volatile Memory B.

 

 

 

 

PWR_SUPPL.. Control circuits power supplies

 

 

 

ANLG_REF ....

Analog section reference voltage.

 

 

 

DAC

Digital to Analog Converter.

 

 

 

 

ANLG_MUX ..

Analog signal paths.

 

 

 

 

Light shaded bits are of tests performed during Power-On only.

Dark shaded bits are of tests performed during both Power-On and Power Module Test.

A set bit indicates a fault.

BYTE 2

 

 

 

 

 

VSET

IOUT

VLOAD

VOUT

 

 

 

 

 

 

 

 

 

VOUT

VOUT measurement confidence test.

VLOAD

VLOAD measurement confidence test.

IOUT

IOUT measurement confidence test.

VSET

VSET controlling signal confidence test.

The Main Controller Confidence Test result is a single byte.

The results of the test can be remotely read using the CONF? query. The result byte has the following format:

 

 

 

 

 

BUFF

SAVE

TABLE

INT

 

 

 

 

 

AREA

AREA

AREA

RAM

 

 

 

 

 

 

 

 

 

INT_RAM

Processor Memory.

 

 

 

TABLE_AREA

.....Main Memory - internal tables.

 

 

 

SAVE_AREA

Main Memory - settings storage areas.

 

 

BUFF_AREA

Main Memory - communications buffers.

 

 

76

XMP 2600 Programming Manual rev. 1.1

Image 89
Contents Xantrex Multiple Output Power System XMP XMP How do you get service? Limited What does this warranty cover and how long does itWarranty Last?Disclaimer Product What does this warranty not cover?Information Information About Your Power SupplyPower Supply Grounding Safety SummaryDescription Power Supply Symbols Output Voltages Input Mains Voltage RatingDo Not Open The Unit Air Inlets And Air Outlet Nonoperative ModulesSafety Agency Compliance Regulatory Approvals and Safety Agency CompliancePower Supply Safety Regulatory ApprovalsWho should use this manual About this manualChapters Terminology Table of contents Basic Programming Commands and Queries Reference Byte Error Codes summaryGpib interface 1Interfacing XMPACK Serial interfaceListening Formats Programming messages formatsResponse Data Separator Talking FormatsUsing the comm. channels How to communicate with the XMPUsing the Gpib bus Using an RS232 linkUsing queries Recovering from communication haltsUsing commands Programming the XMPInitialize the XMP Recommendations on using the XMPSetup the XMP 2600 status system Enforce power-on conditionsQuery installed Power Modules Identify the XMPInitial setup of the Power Modules Setup system level protection shutdown featuresOutput settings Protection setupActivation Status reportingHandling SRQ and the IEEE488.2 Status Structures Using advanced featuresOn-going usage of the XMP Use queriesStatus registers Event enable registersEvent registers Mask registersMain controller events Main status byteOutput message Queue Responding to SRQ eventsPower modules status structure Summary of power modules statusRemote communication time out Primary engine status structureError Code What happens when power is turned onFaults Register Events RegisterUsage Guidelines Output Setup Basic setup and usageOverview of output setup parameters Power Module output ratingOutput control Output settingsOutput activation Globally enabling the outputsCurrent limiting schemes Voltage / current modeFoldback Polarity and disconnect relaysRetry Reprogramming DelayShutdown on current limit Linear foldbackBasic Programming Workpoint window warning Setting the window thresholdsUsage guidelines Enabling the window thresholdsUsing the warnings Using the events mechanismVoltage mode example Checking the statusLoad protection Protection using the workpoint windowAdditional usages OVPTrigger mechanism Arm, trigger, sync and rampSet output to stored values Toggle the output state on/offSync output Output ramping What is output ramping?Synchronization of operations Output ramping setupOutput ramping initiation Simultaneous operationsOutput on/off Using hardware Trig and Sync to serialize operationsOther operations Sequential OperationsController notification of Operation Complete Using software OPC mechanism to serialize operationsSelective shutdown Commands to program shutdown groupingShutdown grouping single, group, global Different shutdown grouping of modulesComm. time out Shutdown on non-fault eventsResponding to communication time out events Time out events as reflected in the status structure Turn-on and reset behaviorCategories Ieee 488.1 BUS CommandsSystem Commands Queries Glbl ResetGLBL? GpibSettings Commands Queries Output Control Protection Read-Back Queries Commands QueriesTrigger Sync Commands Queries Status Reporting Commands Queries Synch Mnemonic Alphabetical referenceParameters None Category System Type Sequential PRE Stores settings of all the Power Modules same as STO command Result register Syntax Return two decimal numbers, in the range 0 to 255. Each bit Cmask Close relay and a value of 1 is returned for an open relay Remove a user message from the XMP 2600 front panel display Set-up the operating mode of the XMP 2600. Re-calculate rqs Response is a series of values one for each installed Power Return output Current measurement of the Power Module. Return the state of the XMP 2600 Local Lock Flag. a value Ocrst Decimal value in the range 0 to Syntax Presence of the Polarity Reversal Relay Option Parameters None Category Settings Type Sequential Master mainframe. For the XMP 2600 this value is String in the following format mssnnn where m=minutes Result is two decimal numbers the first being the level 0t o SN? = Stop = Goto= OFF Module. Result is a decimal number in the range 0 to Shut-down when a remote communication time out occurs. Time out feature Syntax Minus sigh Syntax VLIM? Vset Commands and Queries Reference Events Register Ieee 488.2 compatible Status StructuresError Code Faults RegisterEvents Enable Register Output RegisterEvents Filtering Negative Mask Register Events Filtering Positive Mask RegisterPON CME EXE DDE QYE OPC Standard Event Status Register read with *ESR?Primary Event Status Register read with PER? Primary Status Register read with PSR?Primerr Status Byte Register read with *STB?Self Test Results Power ModulesMain Controller BytePower Modules Errors Reported by the Power Module Error Codes summaryErrors Detected by the Main Controller Main Power Modules Communications errorsParser and Execution errors RS232 Communications errorsGpib Communications errors Status reporting Xantrex Technology Inc