Xantrex Technology XFR 2800 manual Models 60-46 100-28 150-18 300-9 600-4

Page 30

Features and Specifications

Specifications

Table 1.5 Specifications for 60 V to 600 V Models

Models

60-46

100-28

150-18

300-9

600-4

Output Ratings:

 

 

 

 

 

Output Voltage 1

0-60 V

0-100 V

0-150 V

0-300 V

0-600 V

Output Current 2

0-46 A

0-28 A

0-18 A

0-9 A

0-4 A

Output Power

2760 W

2800 W

2700 W

2700 W

2400 W

Line Regulation: 3

 

 

 

 

 

Voltage (0.01% of Vmax + 2 mV)

8 mV

12 mV

1 7mV

32 mV

62 mV

Current (0.01% of Imax + 2 mA)

6.6 mA

4.8 mA

3.8 mA

2.9 mA

2.4 mA

Load Regulation: 4

 

 

 

 

 

Voltage (0.02% of Vmax + 5 mV)

17 mV

27 mV

35 mV

65 mV

125 mV

Current (0.02% of Imax + 5 mA)

14.2 mA

10.6 mA

8.6 mA

6.8 mA

5.8 mA

Meter Accuracy:

 

 

 

 

 

Voltage (1% of Vmax + 1 count)

0.7 V

1.1 V

1.6 V

4 V

7 V

Current (1% of Imax + 1 count)

0.56 A

0.38 A

0.19 A

0.1 A

0.05 A

Output Noise (0-20 MHz):Voltage (p-p)

150 mV

175 mV

200 mV

400 mV

500 mV

 

 

 

 

 

 

Output Ripple (rms):

 

 

 

 

 

Voltage

15 mV

25 mV

25 mV

40 mV

100 mV

Current 5

100 mA

80 mA

40 mA

20 mA

10 mA

Drift (30 minutes): 6

 

 

 

 

 

Voltage (0.05% of Vmax)

30 mV

50m V

75 mV

150 mV

300 mV

Current (0.7% of Imax)

322 mA

196m A

126 mA

63 mA

28 mA

For Resistive Programming:

 

 

 

 

 

Voltage (0.6% of Vmax)

360 mV

600 mV

900 mV

1800 mV

3600 mV

Current (0.6% of Imax)

276 mA

168 mA

108 mA

54 mA

24 mA

Drift (8 hours): 7

 

 

 

 

 

Voltage (0.05% of Vmax)

30 mV

50 mV

75 mV

150 mV

300 mV

Current (0.05% of Imax)

23 mA

14 mA

9 mA

4.5 mA

2 mA

For Resistive Programming:

 

 

 

 

 

Voltage (0.3% of Vmax)

180 mV

300 mV

450 mV

900 mV

1800 mV

Current (0.3% of Imax)

138 mA

84 mA

54 mA

27 mA

12 mA

Temperature Coefficient: 8

 

 

 

 

 

Voltage (0.02% of Vmax/°C)

12 mV

20 mV

30 mV

60 mV

120 mV

Current (0.03% of Imax/°C)

13.8 mA

8.4 mA

5.4 mA

2.7 mA

1.2 mA

For Resistive Programming:

 

 

 

 

 

Voltage (0.06% of Vmax/°C)

36 mV

60 mV

90 mV

180 mV

360 mV

Current (0.06% of Imax/°C)

28 mA

16.8 mA

10.8 mA

5.4 mA

2.4 mA

OVP Adjustment Range:

 

 

 

 

 

(5% to 110% of Vmax)

3-66 V

5-110 V

7.5-165 V

15-330 V

30-660 V

Efficiency: 9

0.90

0.90

0.90

0.91

0.91

28

Operating Manual for XFR 2.8kW Series Power Supply

Image 30
Contents XFR 2800 Watt Series Programmable DC Power Supply Page XFR 2800 Watt Series What will Xantrex do? How do you get service?What does this warranty cover and how long does it last? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DatePower Supply Safety Who Should Use This Manual Main SectionsManual Revisions Power Supply Safety Markings About This ManualContents Section Local Operation Remote CalibrationList of Figures List of Figures List of Tables List of Tables Features and Options DescriptionModel Voltage Range Current Range Features and Specifications Power Supply Front Panel Front Panel ControlsRear Panel Connectors and Switch Power Supply Rear Panel Shows the functions assigned to each SW1 switch Switch Function Open Closed HIGH=OFF HIGH=ONProgramming and Monitoring J2 Connector Connector Reference Name Function VrmtWiring Making J2 ConnectionsSpecifications Models 300 12-220 20-130 33-85 40-70 Features and Specifications Models 60-46 100-28 150-18 300-9 600-4 Features and Specifications Additional Specifications Input ConditionsAdditional Features Remote Programming MonitoringEnvironmental Specifications Mechanical Specifications Output ConnectorDimensional Drawings Basic Setup Procedure IntroductionStep # Description Action Reference Inspection, Cleaning, and Packaging Initial Inspection Periodic CleaningReturning Power Supplies to the Manufacturer Packaging for Shipping or Storage Shipping or Storage Carton LabelLocation, Mounting, and Ventilation Rack MountingAC Input AC Input PowerAC Input Connector Voltage Selection AC Voltage Range FrequencyAC Input Wire Connection Wire Size Ratings Cable Outside DiameterAC Input Cover and Strain Relief Functional Tests Voltage Mode Operation CheckPower-on Check Equipment RequiredCurrent Mode Operation Check Front Panel Function Checks Load Wiring Wire Size Maximum Current aLoad Connection Maximum Load Wire Length for 1 V Line Drop Making Load ConnectionsOutput Strain Relief and Cover Typical Load Connection Hardware Output Voltage Connector To 600 V ModelsSingle Load with Local Sensing Default Multiple Loads with Local Sensing 10Multiple Loads with Remote Sensing Sense Wiring Local and Remote Sensing11J10 Sense Connector Terminal Name FunctionUsing Remote Sensing 12 shows a sample setup for using remote sensing Standard Operation Operating Modes Automatic CrossoverLocal Operation Standard OperationConfiguration ShippedMode Setting Output Voltage Current Limit Using Over Voltage Protection OVP OVPResetting the OVP Circuit Using the Shutdown Function Controlling Shutdown Function via ConnectorLED Using Multiple Supplies Configuring Multiple Supplies for Series OperationConfiguring ParallelSupplies for Supplies for Split Supply Operation Parallel Operation of Multiple SuppliesPositive-negative Supply Split Supply Operation of Multiple SuppliesLocal Operation Over Temperature Protection OTP Switch SW1-8 OTP Shutdown Selection DescriptionUnusual or Erratic Operation User DiagnosticsEmergency Shutdown Abbreviated References Used in TableSymptom Check Further Checks and Corrections Remote Operation Remote Operation Remote Analog Programming ProcedureOptions Control Programming ScalesRemote Operation Power Supply Settings for Different Programming Sources Connecting Programming Sources to J2 Connector Remote Monitoring of Output Voltage and Current Precautions Calibration SetupService EnvironmentAccessing Calibration Potentiometers Programming and Monitoring Calibration Locations Calibrating for Programming Accuracy Voltage Programming Circuit CalibrationCurrent Limit Programming Circuit Calibration Calibrating for Readback Accuracy Output Voltage Monitor Circuit CalibrationOutput Current Monitor Circuit Calibration Calibration Page Xantrex Technology Inc