Features and Specifications
Rear Panel Connectors and Switch
Making J2 Connections
CAUTION
Do not attempt to bias program/monitor signal return (J2 terminals 5, 7, 9, and
11)relative to the supply output because control ground
CAUTION
To maintain the isolation of the power supply output and prevent ground loops, use an isolated (ungrounded) programming source when operating the power supply via remote analog control at the J2 connector.
Make connections to the J2 connector using its
Wiring
WARNING
There is a potential shock hazard when using a power supply with a rated output greater than 40 V. Use wiring with a minimum insulation rating equivalent to the maximum output voltage of the power supply. For example, select
For most connectors and jumpers, use any suitable wire such as 16 to 24 AWG stranded wire. For lowest noise performance, use shielded pair wiring. Strip wires 0.26 in. (6.5 mm), insert, and tighten the wire clamp.
24 | Operating Manual for XFR 2.8kW Series Power Supply |