Installation
Load Connection
150 V to 600 V Models
WARNING
To protect personnel against accidental contact with hazardous voltages, ensure that the load, including connections, has no live parts which are accessible. Also ensure that the insulation rating of the load wiring and circuitry is greater than or equal to the maximum output voltage of the power supply.
The 150 V to 600 V models have a
1.Strip 0.4 in. (10 mm) at the ends of the wires.
2.Remove the top part of the output cover. Do not remove the
3.Loosen wire clamp screws (part of strain relief). Do not disassemble the strain relief.
4.Insert load wire in strain relief.
5.To connect the wiring, loosen each terminal screw, insert a stripped wire into the terminal, and tighten the screw securely.
6.Tighten the strain relief clamp.
7.Replace the top cover.
Negative Output/Return
Positive Output (+)
Figure 2.6 Output Voltage Connector
(For 150 V to 600 V models.)