Xantrex Technology XFR 2800 manual Mechanical Specifications, Output Connector

Page 35

Features and Specifications

Specifications

Mechanical

Specifications

Front Panel V and I Control

10-turn voltage and current potentiometers

 

 

Front Panel Voltage Control

0.02% of maximum voltage

Resolution

 

 

 

Front Panel Voltage and Current

3.5-digit green numeric LED displays. For accuracy

Meters

specifications, see Table 1.4 and Table 1.5.

 

 

AC Input Connector Type

3-terminal 34 A, 250 V, right angle, PC mount, wire

 

clamp connector with removable strain relief cover

 

 

Input Fuses 1

1 A, 250 V, 5 x 20 mm slow fuse (T), location: F34;

 

1.5 A, 250 V, 5 x 20 mm time delay (T), location: F33;

 

20 A, 250 Vac, 5 x 20 mm fast high interrupt (F),

 

location: F36;

 

30 A, 300 Vac, 10.3 x 41.3 mm medium time lag (T),

 

locations: F2, F3.

 

 

Output Connector

7.5 V to 100 V models: nickel-plated copper bus bars

 

with removable bus bar shield; bus bar holes: 0.343 in.

 

(8.7 mm) diameter (D) (1), 0.197 in. (5.0 mm) D (2);

 

150 V to 600 V models: 4-terminal, right angle, PC

 

mount, wire clamp connector with removable strain

 

relief cover.

 

 

Sense Connector

5-terminal wire clamp connector (2 piece)

 

 

Analog Programming Connector

15-terminal wire clamp connector (2 piece)

 

 

Chassis Ground

One chassis ground screw located on rear panel for

 

bonding connections or for wire shield grounding.

 

Maximum penetration into unit is 0.375 in. (9 mm).

 

 

Cooling

Fan cooled. Air exhausts to rear. Over temperature

 

shutdown: automatic restart or latch off

 

(switch-selectable).

 

 

Mounting

Rack mount brackets. Mount at front panel.

 

 

Weight

Approximately 33lb. (15 kg)

 

 

Approvals

CE-marked units are approved to IEC 1010-1 safety

 

standard and EN50081-2 and EN500082-2 EMC

 

standards, and are CSA certified to C22.2 No. 1010.1.

 

CE-marked units are also approved to U.S.

 

requirements of NRTL/C and are UL listed to

 

UL3111-1, 1st edition, (up to 40 °C). Additional

 

standards met: FCC, part 15, class A EMI standard.

1.Fuses are located on the A4 PCB (printed circuit board). The fuses are NOT operator-replaceable.

Release 2.1

33

Image 35
Contents XFR 2800 Watt Series Programmable DC Power Supply Page XFR 2800 Watt Series Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty cover and how long does it last? What will Xantrex do?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplyPower Supply Safety Manual Revisions Who Should Use This ManualMain Sections About This Manual Power Supply Safety MarkingsContents Calibration Section Local Operation RemoteList of Figures List of Figures List of Tables List of Tables Model Voltage Range Current Range Features and OptionsDescription Features and Specifications Front Panel Controls Power Supply Front PanelRear Panel Connectors and Switch Power Supply Rear Panel Shows the functions assigned to each SW1 switch HIGH=OFF HIGH=ON Switch Function Open ClosedProgramming and Monitoring J2 Connector Vrmt Connector Reference Name FunctionMaking J2 Connections WiringSpecifications Models 300 12-220 20-130 33-85 40-70 Features and Specifications Models 60-46 100-28 150-18 300-9 600-4 Features and Specifications Input Conditions Additional SpecificationsRemote Programming Monitoring Additional FeaturesEnvironmental Specifications Output Connector Mechanical SpecificationsDimensional Drawings Step # Description Action Reference Basic Setup ProcedureIntroduction Initial Inspection Periodic Cleaning Inspection, Cleaning, and PackagingReturning Power Supplies to the Manufacturer Shipping or Storage Carton Label Packaging for Shipping or StorageRack Mounting Location, Mounting, and VentilationAC Voltage Range Frequency AC Input PowerAC Input Connector Voltage Selection AC InputWire Size Ratings Cable Outside Diameter AC Input Wire ConnectionAC Input Cover and Strain Relief Equipment Required Voltage Mode Operation CheckPower-on Check Functional TestsCurrent Mode Operation Check Front Panel Function Checks Load Connection Load WiringWire Size Maximum Current a Making Load Connections Maximum Load Wire Length for 1 V Line DropOutput Strain Relief and Cover Typical Load Connection Hardware To 600 V Models Output Voltage ConnectorSingle Load with Local Sensing Default Multiple Loads with Local Sensing 10Multiple Loads with Remote Sensing Local and Remote Sensing Sense WiringTerminal Name Function 11J10 Sense ConnectorUsing Remote Sensing 12 shows a sample setup for using remote sensing Operating Modes Automatic Crossover Standard OperationStandard Operation Local OperationMode ConfigurationShipped Setting Output Voltage Current Limit OVP Using Over Voltage Protection OVPResetting the OVP Circuit Controlling Shutdown Function via Connector Using the Shutdown FunctionLED Configuring Multiple Supplies for Series Operation Using Multiple SuppliesSupplies for ConfiguringParallel Parallel Operation of Multiple Supplies Supplies for Split Supply OperationSplit Supply Operation of Multiple Supplies Positive-negative SupplyLocal Operation Switch SW1-8 OTP Shutdown Selection Description Over Temperature Protection OTPAbbreviated References Used in Table User DiagnosticsEmergency Shutdown Unusual or Erratic OperationSymptom Check Further Checks and Corrections Remote Operation Control Programming Scales Remote Analog Programming ProcedureOptions Remote OperationRemote Operation Power Supply Settings for Different Programming Sources Connecting Programming Sources to J2 Connector Remote Monitoring of Output Voltage and Current Environment Calibration SetupService PrecautionsAccessing Calibration Potentiometers Programming and Monitoring Calibration Locations Voltage Programming Circuit Calibration Calibrating for Programming AccuracyCurrent Limit Programming Circuit Calibration Output Voltage Monitor Circuit Calibration Calibrating for Readback AccuracyOutput Current Monitor Circuit Calibration Calibration Page Xantrex Technology Inc