use the correct connector. The 5012 will not work in the 5011 and
Xerox 5012/5014 OPC
13R19
OEM Stated Yield: 18,000
The 5012 OPC cartridges look very similar to the 1012 and 5011, but they are different and NOT interchangeable.
There are now many different Xerox part numbers for these cartridges. They are interchangeable, just sold from different sources. They are 13R19 (US), 13R22, 13R24, 113R91 (retail), and 13R508.
These cartridges use a reset fuse board located inside the connector. The connector must be
3 & 6. 5012 connectors read 1,500 ohms, while 5011 connectors read 15,000 ohms.
Xerox 5018 OPC
Xerox Cartridge Part # 13R9
OEM Stated Yield:
Machine)
There are a variety of cartridges now available for these machines. They all use the same supplies. 13R9, 13R74(US), 113R161 (Retail) 113R93 (Missing Internal Counter), 13R13(RX), 13R18(XLA), 13R505 (XCL).
The 5334 cartridges appear similar but are different. They still use the same supplies to recycle, but they do not have a reset counter installed inside. They also have an extra tab on the back side of the cartridge that stops the cartridge from being installed completely in a 5018 machine. The cartridges used in these machines are the 13R67 (US), 13R68 (RX/XL), 13R69 (XLA), 13R520 (XCL). These machines are basically set up to “run for
life” in other words, the drum cartridge is run until there is a problem. At that point another cartridge is installed, and the machine continues to print. There is no reset involved.
A code (J2) may show on the 5624, and 5824 machines, to clear it do the following: Enter the diagnostics by holding the ”0” while turning on the machine. Enter “9”, PRINT, “50”, PRINT. This will start the machine up and clear the J2 code. Information on these machines is still a little vague as we are still in the learning process.
The 5018 OPC cartridge must be disassembled so that you have access to the mechanical counter. New OEM replacement belts are now available making any Xerox machine warranty issues hard to enforce.
Turn the cartridge so that the Counter is in front of you. On the left side of the counter, there are two white levers. While pressing both of the levers down, turn the large black gear backwards,(Clockwise). Stop when the green or knurled section of the gear is visible through the small hole in the cover. (You must loosely place the cover over the Waste Chamber; the hole is located under the J2 label. Once this gear is in position, release both of the levers. At this point you should not be able to turn the large black gear. If you can, press down both levers and turn the gear one or two more "clicks" until the gear is locked. The two White Levers should stay flat.
44